No. MIIXR0002EAC DICOM CONFORMANCE STATEMENT MEDIA STORAGE FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A with XIDF-037A and XIDF-038A or SRS-1000A (MIIXR0002EAC) 2001.
No. MIIXR0002EAC IMPORTANT! (1) No part of this manual may be copied or reprinted, in whole or in part, without written permission. (2) The contents of this manual are subject to change without prior notice and without our legal obligation.
No. MIIXR0002EAC Table of Contents Page 1 INTRODUCT ION ................................................................................................................ 1 1.1 R EFERENCES ................................................................
No. MIIXR0002EAC 8.1.1 Media Storage Directory IOD Modules ................................................................ 9 8.1.2 Media Storage XA IOD Modules .......................................................................... 9 8.1.3 XA IOD Modules .
No. MIIXR0002EAC 1 Introduction This document is a DICOM Conformance Statement for Toshiba's Digital Fluorography Systems. It is intended to provide the reader with the knowledge of how to integrate this product within DICOM compliant equipments.
No. MIIXR0002EAC 1.3 Acronyms, Abbreviations and Sy mbols • ACC American College of Cardiology • ACR American College of Radiology • ASCII American Standard Code for Information Interchange • .
No. MIIXR0002EAC 2 Implement ation Model 2.1 Application Data Flow Diagram Transfer of X-r a y Examinat ion DICOM Recording CD-R Medium Review of X-r a y Examinat ion DICOM Reader Legend Applicati on Entity Local Real-W orld Activi ty File-set Creator (FS C) File-set Reader (FS R) Local Relationship Figure 1 2.
No. MIIXR0002EAC 2.2.2 DICOM Reader The DICOM Reader supports the following tasks: • Reads the DICOMDIR file that represent s the contents of t he data as recorded. • Displays the ordered list of patient and image identifying information or icon images.
No. MIIXR0002EAC 2.3.2 Operation 2.3.2.1 Transfer of X-ray Examination The operation for manual transfer of X-ray examination is described below: STEP-1: Select the images or the patient to be transferred. STEP-2: Request transfer. STEP-3: Insert the blank CD-R media.
No. MIIXR0002EAC 3 AE Sp ecifications 3.1 DICOM Recording Specification The DICOM Recording AE provides Standard Conformance to the DICOM Media Storage Service, File Format Class and t he Media Storage Application Profile.
No. MIIXR0002EAC 3.2.1 File Meta Information for the Application Entity The Application Entity Title is not relev ant because this DICOM Reader AE only reads CD-R media. 3.2.2 Real-World Activity 3.2.2.1 Real-World Activity - Review of X-ray Examination DICOM Reader AE acts as a FSR when chosen by the operator.
No. MIIXR0002EAC 5 Extensions, S pecializations, and Privatizations of SOP Classes and T ransfer Synt axes Not applicable to this product. 6 Configuration For the Digital Fluorography System, the configuration can be set.
No. MIIXR0002EAC 8 X-Ray Angiographic Information Object Definition 8.1 Entity Module Definitions The information modules for the X-Ray Angiographic devices are defined below. 8.1.1 Media Storage Directory IOD Modules Table 5 Object Module / key Reference Usage 1 DICOM File Meta Information 8.
No. MIIXR0002EAC 8.1.3 XA IOD Modules Table 7 Information Entity Module Reference Usage 1 Patient Patient Module 8.5.1 M Study General Study Module 8.5.2 M Study Patient Study Module 8.5.3 U Series General Series Module 8.5.4 M Equipment General Equi pment Module 8.
No. MIIXR0002EAC 8.2 DICOM File Meta Information 8.2.1 DICOM File Meta Information of Directory IOD Table 8 Attribute Name Tag Type Attribute Description File Preamble No Tag 1 Alw ays set DICOM Prefi.
No. MIIXR0002EAC 8.3.2 Directory Information Module Table 11 Attribute Name Tag Type Attribute Description Offset of the First Directory Record of the Root Directory Entity (0004, 1200) 1 Always set O.
No. MIIXR0002EAC 8.4.2 STUDY keys Table 13 Attribute Name Tag T ype Attribute Description Study Date (0008, 0020) 1 Alway s set Study Time (0008, 0030) 1 Always set Study Description (0008, 1030) 2 Le.
No. MIIXR0002EAC 8.4.4 IMAGE keys Table 15 Attribute Name Tag Type A ttribute Description Instance Number (0020, 0013) 1 Alway s set Image Type (0008, 0008) 1 Alway s set Image Date (0008, 0023) 3 Alw.
No. MIIXR0002EAC 8.5 XA Information Object Definisions 8.5.1 Patient Module Table 16 Attribute Name Tag Type Attribute Description Patient's Name (0010, 0010) 2 Always set except for urgent patie.
No. MIIXR0002EAC 8.5.4 General Series Module Table 19 Attribute Name Tag Type Attribute Description Modality (0008, 0060) 1 Always set ("XA") Series Instance UID (0020, 000E) 1 Alway s set S.
No. MIIXR0002EAC 8.5.7 Image Pixel Module Table 22 Attribute Name Tag Type Attribute Description Samples per Pixel (0028, 0002) 1 Always set (0x0001) Photometric Interpretation (0028, 0004) 1 Always s.
No. MIIXR0002EAC 8.5.11 X-ray Image Module Table 26 Attribute Name Tag Type Attribute Description Frame Increment Pointer (0028, 0009) 1C Always set (0x00181063) Image Type (0008, 0008) 1 Alw ays set .
No. MIIXR0002EAC 8.5.13 XA Positioner Module Table 28 Attribute Name Tag Type Attribute Description Distance Source to Detector (0018, 1110) 3 Always set [mm] Estimated Radiographic Magnification Fact.
Ein wichtiger Punkt beim Kauf des Geräts Toshiba SRS-1000A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Toshiba SRS-1000A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Toshiba SRS-1000A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Toshiba SRS-1000A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Toshiba SRS-1000A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Toshiba SRS-1000A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Toshiba SRS-1000A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Toshiba SRS-1000A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Toshiba SRS-1000A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.