Benutzeranleitung / Produktwartung AFII 100 des Produzenten Beckett
Zur Seite of 16
RWB 6104 BAFII R01 Page 1 Model AFII Oil Burner Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner: Please read and carefully follow all instructions provided in this manual regarding your responsi- bilities in caring for your heating equipment.
Page 2 RWB 6104 BAFII R01.
RWB 6104 BAFII R01 Page 3 T able of Contents General Information Hazard De fi nitions ...................................................................................................................... .................. 4 Owner ’s Responsibility .
Page 4 RWB 6104 BAFII R01 General Infor ma tion General Information Within the boundaries of the hazard warning, there will be information presented describing consequences if the warning is not heeded and instructions on how to avoid the hazard.
RWB 6104 BAFII R01 Page 5 General Speci fi cation T able 1 – Burner Speci fi cations Capacity ‘HLX’ Heads Firing rate: - 0.40 – 1.50 GPH Input: Min./Max - 56,000 /210,000 Btu/h ‘FBX’ Heads Firing rate: - 0.40 – 1.35 GPH Input: Min./Max.
Page 6 RWB 6104 BAFII R01 Inspect/Prepar e Installation Site Inspect Chimney or Direct V ent System Inspect the chimney or vent. Make sure it is properly sized and in good working condition. Follow the in- structions supplied by the appliance manufacturer .
RWB 6104 BAFII R01 Page 7 Never use T e fl on tape on fuel oil fi ttings. T ape fragments can lodge in fuel line components and fuel unit, damaging the equipment and pre- venting proper operation. Use oil-resistant pipe sealant compounds. • • • Damage to the pump could cause impaired burn- er operation, oil leakage and appliance soot-up.
Page 8 RWB 6104 BAFII R01 The burner is supplied with either a one-stage pump or a two-stage pump based on the oil supply system requirements. Consult the instructions pro- vided with the pump for installation speci fi cations.
RWB 6104 BAFII R01 Page 9 Star t the Bur ner and Set Combustion Figure 4. – T ypical Wiring, R7184 Primary Control SK9359 7. RECYCLE. If the fl ame is lost while the burner is fi ring, the control shuts down the burner , enters a 60 second recycle delay , and then repeats the above ignition sequence.
Page 10 RWB 6104 BAFII R01 If the burner locks out on safety during bleed- ing, reset the safety switch and complete the bleeding procedure. Note — Electronic safety switches can be reset immediately; others may require a three- to fi ve-minute wait.
RWB 6104 BAFII R01 Page 1 1 If motor is not permanently lubricated, oil motor with a few drops of SAE 20 nondetergent oil at each oil hole. DO NOT over oil motor . Exces- sive oiling can cause motor failure. Check motor current. The amp draw should not exceed the nameplate rating by more than 10%.
Page 12 RWB 6104 BAFII R01 Inspect the nozzle adapter before installing the new nozzle. If it is grooved or scratched on the sealing surface, replace the nozzle line assem- bly . If the surface is damaged, oil could leak at the nozzle to adapter joint, causing serious com- bustion problems.
RWB 6104 BAFII R01 Page 13 Stop Screw AFII 85 AFII 100 AFII 150 0 0.40-0.65 0.5-0.65 0.75-1.00 1 - 0.6-0.75 0.85-1.10 2 - 0.65-0.80 0.95-1.15 3 0.60-0.75 0.65-0.90 0.95-1.20 4 - 0.75-0.95 1.10-1.25 5 0.70-0.85 0.85-1.00 1.15-1.35 6 - 0.95-1.10 1.15-1.
Page 14 RWB 6104 BAFII R01 For best performance specify genuine Beckett replacement parts R eplacement Par ts Diag r am Beckett 10 8 21 11 16 17 6 18 14 7 4 20 22 9 5 15 2 13 23 3 19 12 1 SK8265B.
RWB 6104 BAFII R01 Page 15 Item Description Kit No. 1 Air tube combination Specify 2 Blower Wheel: AFII 85 (4-1/4”) AFII 100 (4-1/2”) AFII 150 (4-1/2”) 21439U 21438U 21438U 3 Electrical box 3061.
Page 16 RWB 6104 BAFII R01 Limited WARRANTY For Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its Beckett burners from Be.
Ein wichtiger Punkt beim Kauf des Geräts Beckett AFII 100 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Beckett AFII 100 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Beckett AFII 100 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Beckett AFII 100 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Beckett AFII 100 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Beckett AFII 100 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Beckett AFII 100 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Beckett AFII 100. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Beckett AFII 100 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.