Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner: y Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment. y Contact a professional, quali fi ed service agency for installation, start-up or service work.
2 Contents Burner Application Scope and Intended Use ........... 2 Prepare Before Installing ............................................ 3 Speci fi cations ..................................................................... 3 Notice Special Requirements.
3 12 Vdc ADC Burner Manual Section: Prepare Before Installing Owner ’ s Responsibility Incorrect installation, adjustment, and use of this burner could result in severe personal injury , death, or substantial property damage from fi re, carbon monoxide poisoning, soot or explosion.
4 Figure 1. T ypical Burner Nameplate T able 1. Low Firing Rate Baf fl e Head T ype Low Firing Rate Baf fl e (if speci fi ed) F0 up to 0.65 gph F3 up to 0.85 gph F4 or F6 up to 0.90 gph T able 2. Air Tube Combination (A TC) Codes Firing Rate GPH Head Static Plate Size A TC Codes for Usable Air T ube Lengths: (‘A ’ in inches see Fig.
5 12 Vdc ADC Burner Manual 10 11 6 8 1 2 7 4 9 3 5 4 90 ° Contacts to be parallel with horizontal center line within 2°. Electrode gap to be centered with nozzle center .
6 Figure 4. ‘Z’ Dimensions Using Gauge SK9787 Section: Nozzle Assembly Maintenance B. Check/Adjust Electrodes Check the electrode tip settings. Adjust if necessary to comply with the dimensions shown in Figure 2 . T o adjust, loosen the electrode clamp screw and slide/rotate electrodes as necessary .
7 12 Vdc ADC Burner Manual For oil supply system speci fi cations for tanks not mounted on machines, carefully follow the pump manufacturer ’s literature and the latest edition of the National Fire Protection Association (NFP A) 31 standard. Pumps with automatic bypass do not require a bypass plug.
8 Section: Burner Wiring Figure 6A. T ypical Wiring For Constant Duty Ignition - With No Primary Control Figure 6B. T ypical Wiring For Interrupted Ignition - With No Primary Control 30A FUSE IGNITER .
9 12 Vdc ADC Burner Manual Figure 6C. T ypical Wiring with 7556 Primary Safety Control Section: Drive Component Maintenance Driv e Component Maintenance A.
10 Section: Drive Component Maintenance B. Pump Maintenance General Pump Information Important information - Long or oversized inlet lines may require the pump to operate dry during initial bleeding period. In such cases, the priming may be assisted by injecting fuel oil in the pump gear set.
11 12 Vdc ADC Burner Manual Section: Start Up Burner & Set Combustion Explosion and Fire Hazard Failure to follow these instructions could lead to equipment malfunction and result in heavy smoke emission, soot-up, hot gas puff-back, fi re and asphyxiation hazards.
12 Section: Maintain & Service Burner Professional Service Required Incorrect installation, adjustment, and use of this burner could result in severe personal injury , death, or substantial property damage from fi re, carbon monoxide poisoning, soot or explosion.
13 12 Vdc ADC Burner Manual T roubleshooting Oil burners that are designed for use on road maintenance equipment are built to take temperature extremes, vibration, and rough handling.
14 Section: T roubleshooting T able 4. Troubleshooting Chart Symptom Possible Cause Oil Not Igniting If the burner is not igniting, the burner motor , drive coupling, and oil pump are operating and oil is fl owing to the nozzle through the solenoid valve, check the following possibilities.
15 12 Vdc ADC Burner Manual 1 2 3 4 5 6 7 8 9 12 10 11 13 14 15 16 18 19 17 21 20 22 23 R eplacement P ar ts Illustration # Description Part# 1 DC Motor n/a 2 Blower Wheel 2999U 3 Coupling 2140501 4 A.
The R. W . BECKETT CORPORA TION (“Beckett”) warrants to persons who purchase its “Products” from Beckett for resale, or for incorporation into a product for resale (“Customers”), that its equipment is free from defects in material and workmanship.
Ein wichtiger Punkt beim Kauf des Geräts Beckett ADC (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Beckett ADC noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Beckett ADC - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Beckett ADC reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Beckett ADC erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Beckett ADC besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Beckett ADC verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Beckett ADC. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Beckett ADC gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.