Benutzeranleitung / Produktwartung TDC-100/200 des Produzenten Toro
Zur Seite of 20
T T D D C C - - 1 1 0 0 0 0 / / 2 2 0 0 0 0 U U s s e e r r ’ ’ s s G G u u i i d d e e.
2 2.
Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 General Editing - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 Timing Mech.
The T oro TDC-100/200 combines modular flexibility , ease of use and increased programmability in a single controller . Modularity means flexibility . The TDC-100/200 can control up to 200 stations.
1 Left and Right Arrows allow you to select the next entry field within the same menu line. Any changes will be saved after you exit that entry field. 2 Up and Down Arrows allow you to scroll up and down through the menu items. 3 LCD Panel is the display screen.
16 Power LED 17 Daughter Board Fuse (8), 3.15A Fast-Blow Daughter Board Components 6 6 1 Station W atering LED 2 Pump ON LED 3 Pump Pressur e LED 4 Rain Sensor LED 5 Power LED 6 PC Connection LED 7 Tx LED 8 Rx LED 9 Mother Board Fuse, 3.
Upon power-up, the controller will display: The TDC-100/200 will initiate a diagnostic test automatically during power-up. This function will take approximately ten seconds and it can not be bypassed. If a problem is detected during the diagnostic test, it will be indicated on the display .
System Settings allows you to set controller parameters such as T ime, Date and Language. Use the Up or Down Arrows to navigate through the menus. Use the Left and Right Arrow to advance to the next entry field on the same menu line. Use the Input Dial to select values when editing.
Hold For: – Use this function to suspend controller operation and choose the suspension duration from T oday , 02-30 days, Permanent or None. Reset Pr g’ s: – Use this function to reset all controller irrigation program by selecting Y es. After selecting Y es, press the Up or Down Arrows to activate.
Station Settings allows you to set parameters specific to each station. Use the Up or Down Arrows to navigate through the menus. Use the Left and Right Arrow Keys to advance to the next entry field on the same menu line. Use the Input Dial to select values when editing.
The TDC-100/200 features 10 fully-independent resident programs. With two types of programs to select from, you can further custom fit your irrigation programs to any landscape. • Standard Irrigation Pr ogram will activate a station or group of stations with six start times on a daily basis.
8. Press the Down Arrow to advance the cursor to the Sta Dly: field. Use the Left and Right Arrow Keys to navigate between the Hour and Minute fields. Use Input Dial to set the Station Delay duration. Station delay is the wait period when a station finished watering and when the next station is activated.
Grow In Irrigation Pr ogram Setting: Grow In Irrigation Program example: Create program 3 with stations 21–30 for 5 minutes each with no percent adjustment. Set the start time at 6:30 am and the end time at 4:00 pm. Set the delay for 2 hours and 15 minutes and the maximum simultaneous active station to 5.
The Manual W atering functions are used for additional watering if the irrigation program is not sufficient. They can also be used to troubleshoot each station for proper operation. Pressing the Manual W atering Key will access three manual irrigation functions; Multi-Manual, Syringe and Program.
Syringe - Choose Syringe to activate all the stations in a selected irrigation program for a specified runtime. Note: The Maximum number of simultaneous stations set in the program still applies. Manual Syringe Activation Directions Syringe activation example: Manually activate all the stations in Program 3 for 2 minutes each.
The percent adjust function allows you to fine tune irrigation programs. With weather conditions changing constantly , Percent Adjust allows you to tune your system easily without changing all the values in the program. Important: The settings do not override each other , instead, they multiple each other to get the effective adjustment.
The Pause command is used to suspend active program or manual irrigation. The Pause function allows the user to specify the pause duration. Pause / Resume Function Directions Pause function example: Program 01 has been manually activated. Pause program 01 for 30 minutes.
Pause Function TDC-100/200 Action Pause Program XX Allow the start of other programs, multi-manuals and syringe. If the start time of the paused program occur ’s again while still on Pause, that runtime will be stacked (delayed until the first occurrence is completed).
The diagnostics function allows the user to monitor Radio Link status, check the firmware version, troubleshoot stations using the Sequence Stations options, monitor the system’s water usage, monitor all system’ s sensor status, monitor system’s voltages, check alarm status, clear alarms and execute a self diagnostics to the system.
Power Supply: 1.5A On/Off Switch/Circuit Breaker – Main Power Input 3.15A Fuse (Slow-Blow) – Field Output Mother Board: 3.15A Fuse Line V oltage: 100, 220 or 240 V AC 50/60 Hz, 98 V A Current Draw (no load): 0.21A @ 100-120 V AC, 60 Hz or 0.10A @ 200-240 V AC, 50 Hz Current Draw (maximum load): 0.
Ein wichtiger Punkt beim Kauf des Geräts Toro TDC-100/200 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Toro TDC-100/200 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Toro TDC-100/200 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Toro TDC-100/200 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Toro TDC-100/200 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Toro TDC-100/200 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Toro TDC-100/200 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Toro TDC-100/200. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Toro TDC-100/200 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.