COMPLETE WEATHER STA TION USER’S MANU AL TEXAS ELECTRONICS , INC. 5529 Redfie ld St. Da llas, TX 7523 5 P.O. Box 72 25 Dallas, T X 75209 Phone (214) 631-2490 Fax (214) 6 31-4218 Toll Fre e (800) 42 .
SERIES 525 RAINFALL SENSORS DESCRIPTION The sensor consists of a gold anodized alum inum collector funnel with a k nife-edge that diverts the water to a tipping bucket mechanis m. The models TR-525 I and TR-525USW are calibrated in inches (.01 ” per tip) and model TR-525M is calibrated in mi llimeters (.
ORDERING INFORM ATION Model # Description TR-525I Rain Gauge, 6.06” collecto r, English (Please specif y for calibrati on of 0.2 mm/tip) TR-525USW Rain Gauge, 8.
MODEL 525 TIPPING BUCKET RA IN GAUGE TRANSMITTER INSTALLATION INSTR UCTIONS A clear and unobstructed moun ting location is necessar y to obtain accurate rainfall readings. This transmitter has prov isions for mounting two wa ys, surface mounting and mast mou nting.
FIELD CALIBRATION TR-525I & TR-525M Absolutely accurate calibration can be obt ained onl y with laboratory equipment, but an approx imate field check can be easily made. The tipping bucket mechanis m is a simple and highl y reliable device. The transm itter must be located in a clear area, awa y from trees, buildings, etc.
MODEL TTH-1315 TEMPERATURE HUMIDITY SENS OR DESCRIPTION The Texas Electronics, Inc. Model TTH-1315 S ensor utiliz ed a Rotronics HygroClip S3 Humid ity Temperature Probe with interchangeabl e sensing elements that do no t require calibration.
Sampling Ti me: <0.7 sec Maximum cab le length: 5 m / 15 ft. for direct output Up to 1 00 m / 325 ft. with signal amplifier Connection T ype: Bayonet cap on mountin g connector Prote ction grade: IP65 ( probe to co nnector) Supply voltage: 3.
MODEL TD-4 WIND DIRECTION SENSOR DESCRIPTION The Texas Electronics, Inc. TD-4 Wi nd Direction Sensor is a mechanic al st y le wind meter that mea sures the horizontal wind az imuth. This unit combines sm all physical size with superior bearin gs to meet the EPA's Prevention of Significant Deteriorati on (PSD) starting threshold requi rements.
FEATURES & BENEFIT S • Superior low starting threshold • Long life hybrid dual wi per potentiometer • No plastic parts for ex tremely long life • Precision stainless stee l bearings for st.
MODEL TV-4 WIND SPEED SENSOR DESCRIPTION The Texas Electronics, Inc. TV-4 Wi nd Speed Sensor is a mechanic al style anemometer that measu res the horizontal velocit y of wind. This unit combines sm all physical size with superior bearin gs to meet the EPA's Prevention of Significant Deteriorati on (PSD) starting threshold requi rements.
Physical: Cup Wheel Dia meter: 6.0" (15 .3 cm) Overall Hei ght: 4.75" (12.1 cm) Turning Radiu s: 3.0" (7. 6 cm) Cup Diameter: 2.0" (5. 1 cm) Bearings: APEC 3 or b etter Mounting B ase: Screw attach ment, 10 -32 machine scre w Weight: 0.
MODEL SP-LITE SOLAR RAD IATION SENSOR DESCRIPTION The Texas Electronics, Inc. SP -Lite Solar Radiation Sensor util izes a Kipp & Zonen Silicon p yra nometer mounted in a white baked-enamel finished aluminum bracket that provid es a stable upward-facing in stallation.
Mechanical: Material o f housing: Anod ized aluminum co ntained in whit e baked- enamel finished aluminu m mounting b racket Cable lengt h: 60 ft. Dimensions: He ight fro m surface to top of level P yranometer - - 6.25" (15.87 cm) Width - 2.7 5 " (6 .
Texas Electronics, Inc. Texas Electronics, Inc. Texas Electronics, Inc. Texas Electronics, Inc. Model TB-2012M Barometer Model TB-2012M Barometer Model TB-2012M Barometer Model TB-2012M Barometer Remo.
FEATURES & BENEFIT S • Interfaces to virtuall y all data acquisition systems • Can be used up to 180 0 ft. elevation without factor y modification • Over 1800 ft.
PROPER EXPOSURE OF METEOROLOGIC AL INSTRUMENTS Generally recognized gui delines follow which depict "ideal" sensor mounting locations. Th ese guidelines or "rules of thumb" are onl y suggestive in nature in an attempt to aid the user to selecting optimum repr esentative sampling locations for a particular sensor.
PRECIPITATION GA UGES: Rain gauges should be installed on a level plot of ground, at a distanc e from any object of at least two and preferably four times the height of the obj ect above the top of the gauge.
Step 2: Attach wind vane and counter-weight to the di rection sensor head. Loosen the two set screws on the top of the wind vane (upper unit). Insert the vane and counter-weight into t he holes. Be sure to press both pa rts all the wa y in and make sure the flat areas on each arm face the set-screws.
Two methods of aligning the vane are av ailable. The first method inv olves loosening the large set screw at the bottom of the wind di rection sensor so that it wi ll rotate on the U-arm. Turn the bottom half of the sensor until t he compass readings and the in dication match then retighten the set scr ew.
Warranty Texas Electronics, Inc. ( hereafter TE I) warrants the equi pment manu factured b y it to be free from defects in material and workmansh ip. Upon return, transportation charges prepaid to TE .
Three-Yea r Warranty Equipment List Effective February 1, 1992 all of Texas Ele ctronics, Inc. sensors will carry a Three-Year warranty instead of the previous One-Year. The remainder of term s and conditions of the warranty rem ains unchanged. A specific list of item s follows.
Ein wichtiger Punkt beim Kauf des Geräts Texas Instruments TR-525USW (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Texas Instruments TR-525USW noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Texas Instruments TR-525USW - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Texas Instruments TR-525USW reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Texas Instruments TR-525USW erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Texas Instruments TR-525USW besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Texas Instruments TR-525USW verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Texas Instruments TR-525USW. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Texas Instruments TR-525USW gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.