Document No. 49-0002-017 Rev. A Installation, Operation & Diagnostics for the MIU202T-S Industrial Grade, Bell 202T-S Standalone Modem.
Document No. 49-0002-017 Rev. A Telenetics Corporation 26772 Vista Terrace Drive Lake Forest, California 92630 (949)455-4000 Fax (949)455-4010.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 1 TABLE OF CONTENTS 1. STANDARDS .... ............................................................................ .............. 2 2. PRODUCT OVERVIEW .. ...............
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 2 Meets FCC Rules Part J, Subpart 15 , Class A for radi at ed emissions.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 3 2. PR ODUCT OV ERVIEW The MIU202T is an industrial grade Bell202T m odem for connecti on to unconditioned and conditioned, voi ce grade, type 3002 two or four-wire leased lines and m eta llic lines (eg; pi lot wires).
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 4 3. GENERAL PR ODUCT SPECIFICATIONS Dimensions: 5.3 x 4.0 x 1.375 inches Weight: 1 l b Voltage Supply : Standard Model : 40 to 270VDC 40 to 270VAC, 50/60Hz LV Model (Suffix “-LV” ): 9 to 36VDC Current Requirements : 12VDC 24VDC 125VD C 120VAC 220VAC 65mA 27m A 7.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 5 4. MODEM SPECIFICATIONS Modulation: Bell202T Modulation Type: FSK Synch/Async: Synchronous or Asynchronous Data Rate:.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 6 Other Features Receiver Equalizati on: Comprom ise Equali zation Self Test Diagnostics: None Local Analog Loopback: S.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 7 5. ANALOG LI NE SPECIFICATIONS The MIU202T contains analog circ uitry for connectio n to the publi c conditione d or unconditioned, Bell type 3002, 2 or 4-wire, full duplex voice grade lea sed lines or meta llic lines (eg; pilot wires).
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 8 6. ANALOG MI CROWAVE INTERFACE The MIU202Tis designed to interfac e to a Microwave radio voice channel network with the following speci fications: Phase Jitter (10 to 300Hz) 1 degree peak-to-pea k, max.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 9 Crosstalk (unint elligible): Adjacent channel 28dBrnc0 maximu m (2 4 4 55 B w ei gh ted noise a t 0 dBm O dBrnc0 t ypical).
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 10 7. POWER CONNECTIONS.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 11 8. SERIAL DATA PORT PIN-OUTS For Synchr onous Mode 6 TxDClk (was DSR) 15 TxDClk 9 RxDClk (was RI) 17 RxDClkl.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 12 9. DIP SWITCH FUNCTIONS IMPORTANT NOTE: Invert m odem t o vi ew dip switches as shown above Table 1 Switch Function .
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 13 Table 2: RTS/CTS Delay T ime 2 Wire 4 Wire Swit ched Carrier Constant Carrier Switch 4 Swit ch 5 Swit ch 9 Soft Carr.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 14 10. MODEM CONFIGURATION The following table provides the Dip Swit ch settings requi red for m ost modem a pplicati o.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 15 11. LED INDICATOR.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 16 12. OUTLINE DRAWING & MOUNTING.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 17 13. DIAGNOSTICS The following pages provide har dware techni ques for diagnosing comm unicati on problems and there by is olating the problem at the local mod e m, th e r e mo te mo de m o r the interconnecting line.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 18 Set Dip Switch 1 OFF (TxA = -10dBm ) and Dip Switch 3 OFF (RxA = -43dB m). CD will be ON. Run a test m essage a t TxD and verify that the sam e message is receive d at RxD with no data errors.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 19 (c) REMOTE DIGITAL LOOPBACK – 4/Wire Network (Figure 5) Configure both the l ocal and remo te modem s as follows: .
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 20 (d) LINE DIAGNOSTICS (i) Typical m odem configuration for 4-wi re Point-to-Point system… Switch 1 = ON (TxA = 0dBm ) Switch 3 = ON (RxA = -33dBm ) Switch 4 = OFF (RTS/CTS = 1ms) Switch 5 = OFF (RTS/CTS = 1m s) Switch 6 = ON (Const ant Carrier m ode).
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 21.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 22.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 23.
MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 24 NOTES:.
Ein wichtiger Punkt beim Kauf des Geräts Telenetics MIU202T-S (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Telenetics MIU202T-S noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Telenetics MIU202T-S - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Telenetics MIU202T-S reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Telenetics MIU202T-S erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Telenetics MIU202T-S besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Telenetics MIU202T-S verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Telenetics MIU202T-S. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Telenetics MIU202T-S gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.