Document No. 49-0002-011 Rev. B Installation, Operation & Diagnostics for the MIU202T Industrial Grade, Bell 202T Standalone Modem.
Document No. 49-0002-011 Rev. B Telenetics Corporation 25111 Arctic Ocean Lake Forest, California 92630 (949)455-4000 Fax (949)455-4010.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 1 TABLE OF CONTENTS 1. STANDARDS .............................................................................................. 2 2. PRODUCT OVERVIEW ..................
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 2 1. STANDARDS Meets FCC Rules Part J, Subpart 15, Class A for radiated em issions.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 3 3. GENERAL PRODUCT SPECIFICATIONS Dimensions: 5.3 x 4.0 x 1.375 inches Weight: 1 l b Voltage Supply : Standard Model: 40 to 270VDC 40 to 270VAC, 50/60Hz LV Model (Suffix “-LV”): 9 to 36VDC Current Requirements : 12VDC 24VDC 125VDC 120VAC 220VAC 65mA 27m A 7.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 4 4. MODEM SPECIFICATIONS Modulation: Bell202T Modulation Type: FSK Synch/Async: Asynchronous Only Data Rate: 0 – 1.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 5 Other Features Receiver Equalization: Compromise Equalization Self Test Diagnostics: None Local Analog Loopback: Se.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 6 5. ANALOG LINE SPECIFICATIONS The MIU202T contains analog circuit ry for connection to the public conditioned or unconditi oned, Bell type 3002, 2 or 4-wi re, full duplex voice grade leased lines or metallic lines (eg; pilot wires).
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 7 6. ANALOG MICROWAVE INTERFACE The MIU202Tis designed to interface to a Microwave radio voice channel network with the fo llowing specifications: Phase Jitter (10 to 300Hz)1 degree peak-to-peak, max.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 8 Crosstalk (unintelligib le): Adjacent channel 28dBrnc0 ma ximum (24 455B weighted noise at 0 dBmO dB rnc0 typical).
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 9 7. POWER CONNECTIONS.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 10 8. SERIAL DATA PORT PIN-OUTS.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 11 9. DIP SWITCH FUNCTIONS IMPORTANT NOTE: Invert m odem to view di p switches as shown above Table 1 Switch Function.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 12 Table 2: RTS/CTS Delay Time 2 Wire 4 Wire Switched Carrier Constant Carrier Switch 4 Switch 5 Switch 9 Soft Carrie.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 13 10. MODEM CONFIGURATION The following table provi des the Dip Switch setti ngs required for most modem application.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 14 11. LED INDICATOR.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 15 12. OUTLINE DRAWING & MOUNTING.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 16 13. DIAGNOSTICS The following pages provide hard ware techniques for diagnosing comm unication problems and t hereby isolating the problem at the local modem, the remote modem or the interconn ecting line.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 17 Set Dip Switch 1 OFF (TxA = -10dBm) and Di p Switch 3 OFF (RxA = -43dBm). CD will be ON. Run a test message at TxD and verify that the sam e message is received at RxD with no data errors.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 18 (c) REMOTE DIGITAL LOOPBACK – 4/Wire Network (Figure 5) Configure both the local and rem ote modem s as follows:.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 19 (d) LINE DIAGNOSTICS (i) Typical m odem configurati on for 4-wire Point-to-Point system… Switch 1 = ON (TxA = 0dBm ) Switch 3 = ON (RxA = -33dBm ) Switch 4 = OFF (RTS/CTS = 1m s) Switch 5 = OFF (RTS/CTS = 1m s) Switch 6 = ON (Constant Carrier mode).
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 20.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 21.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 22.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 23 Addendum: 202T built on 1224 printed circuit board. Test Functions: A mom entary push button swit ch and two yellow LED’s are provi ded to perform the test funct ions.
Ein wichtiger Punkt beim Kauf des Geräts Telenetics MIU202T Modem (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Telenetics MIU202T Modem noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Telenetics MIU202T Modem - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Telenetics MIU202T Modem reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Telenetics MIU202T Modem erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Telenetics MIU202T Modem besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Telenetics MIU202T Modem verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Telenetics MIU202T Modem. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Telenetics MIU202T Modem gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.