Document No. 49-0002-001 Rev.A Installation, Operation & Diagnostics for the MIU2.4 MIU9.6 MIU14.4 MIU28.8 Industrial Grade Dial Modems Book 1 of 2 (See Book 2 for AT Commands).
Document No. 49-0002-001 Rev.A Telenetics Corporation 26772 Vista Terrace Drive Lake Forest, California 92630 (949)455-4000 Fax (949)455-4010.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 1 TABLE of CO NTENTS 1. STANDARDS ............... ........................................................... .......... Page 2 2. PRODUCT OVERVIEW ......... .................
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 2 1. STANDARDS All Telenetics dial-up modems are design ed to m eet the following Standards: USA: FCC Part 15, Cl ass A and .
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 3 2. PR ODUCT OV ERVIEW The MIU2.4, MIU9.6, MIU14.4 & MIU28.8 are industri al grade dial modem s for connection to the Publ ic Switche d Telephone Network.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 4 Industrial: The MIU is packaged in a rugged, c ompact, non- metal lic (ABS) enclosure. Designed for unm anned locations, the MIUs do no t include the array of pushbuttons and LEDs norm ally associated with consumer-ty pe modems .
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 5 3. GENERAL PR ODUCT SPECIFICATIONS Dimensions: 5.3 x 4.0 x 1.375 inches Weight: 1 lb Voltage Supply : Standard Model : 40 to 270VDC 40 to 270VAC, 50/60Hz LV Model (Suffix “-LV” ): 9 to 36VDC Current Requirements: (See S ection 4 for Power Down Modes) MIU2.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 6 4. POWER MODES Mode Description Power Consumption Power On Factory Setting : Full power is always available to the m odem. See Section 3 Sleep If the modem is on hook for a predetermined peri od (PE2400 = 5 seconds; PE 2496, PE 14.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 7 5. MODEM SPECIFICATIONS MIU2.4 MIU9.6 MIU14.4 MIU28.8 Standards V.22bi s V.22 Bel l212A Bell 103 V.22bis V.22 Bell212A Bell 103 V.32bis V.32 V.22bis V.22 Bell212A Bell 103 V.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 8 6. POWER CONNECTIONS.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 9 7. SERIAL DATA PORT PIN-OUTS.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 10 8. DIP SWITCH SETTINGS Not Applic able.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 11 9. LED INDICATOR The MIU has a single LED that will i ndicate the foll owing conditions.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 12 12. OUTLINE DRAWING & MOUNTING.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 13 13. MODE M CONFIGURATION Telenetics dial and l eased line modem s are based upon Rockwell chipsets. These chipsets cont ai n Rockwell’s “AT” com mand set. A summ ary of the Rockwell comm and set for your MIU m odem is provided in Book 2.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 14 14. FACTORY CO NFIGURATION ~ MIU2.4 ACTIVE PROFILE: B1 E1 L2 M1 Q0 V1 X4 Y0 &C1 &D0 &G0 &J0 &L0 &.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 15 14. FACTORY CO NFIGURATION ~ MIU9.6 ACTIVE PROFILE: B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C 1 &D2 &G0 &J0 &.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 16 14. FACTORY CO NFIGURATION ~ MIU14.4 ACTIVE PROFILE: B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C1 &D2 &G0 &J0 &.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 17 14. FACTORY CO NFIGURATION ~ MIU28.8 ACTIVE PROFILE: B0 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C1 &D0 &G2 &J0 &.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 18 15. DIAGNOSTICS The following pages provi de softwa re and hardware techniques for diagnosing comm unicat ion problems and thereby is olating the problem at either the local m odem, the rem ote modem or the int erconnecti ng line.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 19 &T0 TERMINATE TEST IN PROGRESS If a V.54 loopback test is in progre ss as a result of executing an &Tn comm and, then the &T0 comm and will cau se that test to be terminated, provided that t he modem is in the command state or a V.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 20 &T2 NO FUNCTION &T3 PERFORM LOCAL DIGI TAL LOOPBACK (See Figure 3) Th e mo dem mu s t be in th e c omma n d state with connection establ ished when this comm and is i ssued, otherwise an ER RO R result code occurs.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 21 &T5 DENY RDL REQUES TS The m odem wil l not respond to a rem o te digital loopback request from a distant modem. Th is will result in an error if the command is given while any V.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 22 &T7 INITIATE RDL WITH LOCAL SELF TEST (See Figure 5) This is a system test, end to end . The comm and is valid only if the modems are i n the command st ate with a connection established.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 23 &T8 LO CAL LOOPBACK WITH SEL F TEST (See Figure 6) The m odem shoul d be on hook. Enter AT&T8 to configure t he modem for analog loopback and sel f test. Th e test tim er is started at the time indicated by S18, DS R is turned off (i f &S1 is in effect ).
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 24.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 25.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 26.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 27 ADDITIONAL TEST / DI AGNOSTICS COMMANDS... %L RECEIVED SIGNAL LEVEL Returns a value (-dBm) wh ich in dicates the received signal level at modem DATA PUMP in terface.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 28 0 Normal hang up; no error occ urred. 4 Physical carrier loss. (Loss of Carri er) 5 F eature negotiation failed to de te ct presence of another V.42 error-control m odem a t other end.
MIU Installation, Operation & Diagnostics Edit ion: March 30, 1998 Page 29 NOTES:.
Ein wichtiger Punkt beim Kauf des Geräts Telenetics MIU14.4 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Telenetics MIU14.4 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Telenetics MIU14.4 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Telenetics MIU14.4 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Telenetics MIU14.4 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Telenetics MIU14.4 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Telenetics MIU14.4 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Telenetics MIU14.4. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Telenetics MIU14.4 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.