Benutzeranleitung / Produktwartung MIU Dial or Leased Line modem with RS-485 des Produzenten Telenetics
Zur Seite of 16
Installation, Operation and Diagnostics for your Communication Interface Unit MIU(Dial or Lease Line modem with) / 485 (RS485) ~ See MIUXXX for modem Technical Data Edition: June 17 , 2003 P / N: 0049.
Installation, Operation & Diagnostics Edition: June 17 , 2003 Install Op and Diags for MIU Modems and RS485 (0049 - 0002 - 010A) TABLE of CONTENTS 1.PRODUCT OVERVIEW ......................................................................... Page 1 2.
Install Op and Diags for MIU Modems and RS485 (0049 - 0002 - 010A) Page 1 of 16 1. PRODUCT OVERVIEW The CIU (MIU XXX485) is an industrial modem with an RS - 232 to RS485 converter module for direct connection to industrial RS485 Interface units.
Install Op and Diags for MIU Modems and RS485 (0049 - 0002 - 010A) Page 2 of 16 3. MIU'S LED, SWITCH & SERIAL CONNECTOR SPECIFICATIONS The CIU/485 communicates with industrial controllers through RS - 485 compatible serial signaling. The RS - 485 signal levels ar e used to interconnect with RS - 485 compatible embedded controllers.
Install Op and Diags for MIU Modems and RS485 (0049 - 0002 - 010A) Page 3 of 16 3.5 MIU/485 B switch (external) SB - 1 Closed (ON) RS485 Received RX & /RX DC terminated with SB - 2 Closed SB - 1 O.
Install Op and Diags for MIU Modems and RS485 (0049 - 0002 - 010A) Page 4 of 16 4. POWER SUPPLY SPECIFICATIONS The MIUXXX/485 contains a low quiescent power regulator. TheMIUXXX/485 also has a "low power" standby mode which minimizes overall power requirements when the MIUXXX/485 is used intermittently.
Install Op and Diags for MIU Modems and RS485 (0049 - 0002 - 010A) Page 5 of 16 5. RS485 SPECIFICATIONS MIUXXXX/485 are low - power Transceiver for RS485 and RS422 communication Features: Point to Poi.
Install Op and Diags for MIU Modems and RS485 (0049 - 0002 - 010A) Page 6 of 16 Operating Temperatures - 40 to 85 o C Storage Temperature - 55 to 100 o C Relative Humidity 0 to 95% is non - condensing. Altitude 20 ,000 ft (operating), 40,000 ft (shipping).
CIU Installation, Operation & Diagnostics Edition: June 17 , 2003 SHEET TWO MIUXXX 485 Power Connection RJ11 Leased Line Port LED 1 Earth/Digital Ground (Jump pins if req’d) DB9 Data Port Power.
CIU Installation, Operation & Diagnostics Edition: June 17 , 2003 SHEET TWO B Point-to-Point, 4-Wire: Set Switches B-3 & B-4 DOWN(OFF) Point-to-Point, 2-Wire: Set Switches B-3 & B-4 UP(ON).
MIUXXX/4 85 Installation, Operation & Diagnostics Edition: June 17 , 2003 Page A - 1 APPENDIX A. CONNECTOR PIN DEFINITIONS CONNECTOR P2 : RS - 232 Configuration Connector (DB9) MIU DCD 1 data carr.
CIU Installation, Operation & Diagnostics Edition: June 17 , 2003 Page C - 1 APPENDIX B. SETUP CONFIGURATION In order to configure the MIUXXX/485 to remote RTU, Meter or Sc ada terminals the follo.
CIU Installation, Operation & Diagnostics Edition: June 17 , 2003 Page C - 1 1:AT Command (MIU2400/485) (Dial) configuration is: AT E0Q1&C1&D0S0=1&W0 E0 Echo Command disables (no ".
CIU Installation, Operation & Diagnostics Edition: June 17 , 2003 Page C - 1 &Z3=XX Password to exit security mode &C1 Carrier Detect is always True (MIU LED will be ON all the time wh en Carrier Detect is ON. &D0 DTR is ignored &K0 No flow control 4: AT Command (MIU9.
CIU Installation, Operation & Diagnostics Edition: June 17 , 2003 Page C - 1 SB - 1 Closed(ON) DC Terminated SB - 2 Closed (ON) Line Termination SB - 3 & - 4 Open (OFF) 4 - wire SA - 1 Open (O.
CIU Installation, Operation & Diagnostics Edition: June 17 , 2003 Page C - 1 To test RS485 module set switch SB - 3 & - 4 Closed (ON) to loopback data to the host modem.
Ein wichtiger Punkt beim Kauf des Geräts Telenetics MIU Dial or Leased Line modem with RS-485 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Telenetics MIU Dial or Leased Line modem with RS-485 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Telenetics MIU Dial or Leased Line modem with RS-485 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Telenetics MIU Dial or Leased Line modem with RS-485 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Telenetics MIU Dial or Leased Line modem with RS-485 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Telenetics MIU Dial or Leased Line modem with RS-485 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Telenetics MIU Dial or Leased Line modem with RS-485 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Telenetics MIU Dial or Leased Line modem with RS-485. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Telenetics MIU Dial or Leased Line modem with RS-485 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.