Benutzeranleitung / Produktwartung 99101100 des Produzenten System Works
Zur Seite of 15
REV. F 5-1-01 1 P/N 99101100 T able of Contents SECTION I. PUMP SAFETY INSTRUCTIONS ------------------------------------------------------- 2 SECTION II. HOW YOUR FIL TER WORKS ----------------------------------------------------------- 2 SECTION III.
P/N 99101100 2 REV. F 5-1-01 SECTION I. PUMP SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: 1 .
REV. F 5-1-01 3 P/N 99101100 SECTION III. CHECK VALVE INSTALLATION INSTRUCTIONS A . INSTALLATION 1 . Turn the pump off, shut off any automatic controls to assure that the system is not inadvertently started during servicing. 2 . Open the High Flow™ manual air relief valve.
P/N 99101100 4 REV. F 5-1-01 6 . Insert the Check Valve into the outlet port approximately 3/4" to 1" deep making sure the rubber diaphragm facing outward (towards you), see Diagram 1. 7 . Reconnect the return hose to the outlet port and tighten the union fitting.
REV. F 5-1-01 5 P/N 99101100 5 . Do not mount electrical controls (on/off switches, timer, etc.) over the filter. You need to be able to stand clear of the filter when starting the pump. 6 . Attach the hair and lint pot to the front of the pump. This is an O-ring seal fitting that requires hand tightening only.
P/N 99101100 6 REV. F 5-1-01 SECTION V. INITIAL START-UP AND RESTART INSTRUCTIONS. 1 . Be sure all connections have been made and are secure. 2 . Make sure the hair and lint pot of the pump is filled with water. (FAILURE TO FILL THE HAIR AND LINT POT WITH WATER WILL RESULT IN DAMAGE TO THE PUMP AND PUMP SEAL).
REV. F 5-1-01 7 P/N 99101100 8 . Remove the CARTRIDGE ELEMENT assembly from the filter body by using the lifting handles and pulling straight up. 9 . Remove the CARTRIDGE ELEMENT from the core assembl.
P/N 99101100 8 REV. F 5-1-01 SECTION VII. WINTERIZING THE FILTER 1 . In areas that have freezing winter temperatures, the pool equipment must be winterized to protect it from damage. 2 . With the pump turned off, open the High Flow™ manual air relief valve.
REV. F 5-1-01 9 P/N 99101100 SECTION IX. TROUBLE SHOOTING Problem Cause Remedy Pool water not 1. Pool chemistry not adequate to inhibit algae growth. Maintain pool chemistry or consult pool service technician . sufficiently clean. 2. Inadequate turnover rate.
P/N 99101100 10 REV. F 5-1-01 3 . SHAFT SEAL - (rotary seal). The shaft seal consists of two parts: a. Rotating ceramic seal, press fitted into the impeller. b. A stationary spring loaded seal, press fitted into the rear of the volute. 4 . THE ELECTRIC MOTOR.
REV. F 5-1-01 11 P/N 99101100 Replacement Parts Find Part Description No. No. 1 98209800 High Flow Manual Air Relief Valve 2 53003201 Pressure Gauge 3 178553 Lid, 50/100 Sq./Ft. 3 178561 Lid, 75 Sq./Ft. 4 59052900 Locking Ring Assy. 5 87300400 Body O-ring 6 59016200 Air Bleed Sock Kit 7 59053500 Center Core, 50 Sq.
P/N 99101100 12 REV. F 5-1-01 SECTION XI. TECHNICAL DATA (continued) B. MAXIM PUMP Find Part Description No. No. 1 98206400 Plug, ¼ in. with O-ring 2 57006500 O-ring 3 39102503 Volute, S Series, vert.
REV. F 5-1-01 13 P/N 99101100 SECTION XI. TECHNICAL DATA, (continued) C. DYNAMO PUMP D Y N A M O C OO SNAP TAB SNAP TAB MOTOR - SEE NOTE 1 SNAP TAB SLOT 18 26 25 24, 24A 20 21 27 19 23 22 12 17 13 14 15 11 10 16 9 9 7 8 6 5 4 3 2 1 * * * Motors 1 35-6471 ¾ A std.
P/N 99101100 14 REV. F 5-1-01 15-5118 2 5 ft. cord and plug 15-5370 2 5 ft. cord and plug, CSA approved 15-5234 3 ft. cord with twist lock plug 35-2245 Strain relief bushing for cords 15-5297 P hoto sensor add-on 2 3 35-4650 B ody - motor enclosure 2 4 35-4656 C a p - motor enclosure 2 5 15-4716 S crew - #10 self-tapping 2 6 15-5371 C ord - 25 ft.
REV. F 5-1-01 15 P/N 99101100.
Ein wichtiger Punkt beim Kauf des Geräts System Works 99101100 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie System Works 99101100 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für System Works 99101100 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von System Works 99101100 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über System Works 99101100 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon System Works 99101100 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von System Works 99101100 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit System Works 99101100. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei System Works 99101100 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.