VF 5 000-C MN -2 V F 6 000-C MN -2 VF 5 000-CM P -2 V F 6 000-CMP-2 US Portland Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHA T T O D O I F Y OU SME LL GAS • Donottrytolightanyappliance.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 2 These heaters are manually controlled. A spark ignition system (piezo) allows the heater pilot gas to be lit without the use of matches or batteries and permits operation of the heater during a power outage.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nau- sea.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 Figure 1 To ensure even heat distribution, it is best to position the heater centrally against the long- est wall of the room. Make sure there is ad- equate ventilation where the heater is installed. The gas appliance will shut off if the oxygen level falls below 18.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 5 PREINSTALLATION Check that all listed parts have been received. Carefully inspect the heater case and contents for shipping damage and immediately inform the dealer from whom you purchased the gas fireplace if any damage is found.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 6 Note: Framing dimensions in Figures 4 - 9 are calculated for a nailing flange depth of ¹⁄₂ " (13 mm). Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 The header may be in direct contact with the top metal spacers, but must not rest on them or be notched to fit around them.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 7 Figure 11 Control Valve Lower Control Compartment Door Step 3. Ensure the hood is properly positioned in the open area above the appliance door. If required insert the tabs, on each end of the hood, into the bracket at each end.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 8 Surround Installations Note: The VF5000/VF6000 series appliances must be installed giving full consideration to the clearance and height requirements identi- fied in this manual.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 9 Figure 17 After setting the logs into position as shown above, ensure they are properly and firmly situated. The heater will not function as in- tended if the logs are not correctly positioned. Periodically check the positioning of the logs.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 10 The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge. The top 3/8" (10 mm) at the pilot generator (thermopile) should be engulfed in the pilot flame (NG only).
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 11 Figure 23 Remote Control Kit The Model RCL adds the convenience of re- mote control for your appliance. The kit in- cludes a wireless, hand held transmitter and a receiver that replaces the wall switch.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 12 ACCESSORIES AND COMPONENTS Forced Air Kit FAB-1100 RCL Remote Control RCL-STAT Rocker Switch Kit FRS Wall Switch Kit FWSK OPERATION AND CARE OF YOUR APPLIANCE 1.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 13 VF5GDK Glass Door Panel VF6GDK Gas Flex Line Kit FFGC VF5RLK Refractory Liner Kit VF6RLK Decorative Volcanic Stone FDVS VF5-PBH Brass Hood Kit VF6-PB.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 14 VF6000 SPECIFICATIONS Figure 25 VF5000 SPECIFICATIONS Figure 24 37" (940 mm) 36" (914 mm) 30" (762 mm) 31-1/2" (800 mm) 15" .
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 15 1. When igniter button is pressed, there is no spark at ODS/pilot. 2. Heater produces unwanted odors. 3. Heater shuts off in use (ODS operates). 4. Gas odor even when control knob is in “OFF” position.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 16 LIGHTING INSTRUCTIONS – MILLIVOLT FOR YOUR SAFETY READ BEFORE LIGHTING • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. • If your gas supplier cannot be reached, call the fire department.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 17 NOTES:.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 18 REPLACEMENT PARTS LIST VF5000-CMN VF6000-CMN VF5000-CMP VF6000-CMP No. Description Part No. Qty. Part No.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 19 REPLACEMENT PARTS 9 10 3 15 14 4 7 6 5 16 13 1 12 (SIT Valve Shown) 14 2 8 11.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 20 Printed in U.S.A. © 1997 by Lennox Hearth Products P/N 903302 REV. N 04 /20 1 0 LHP reserves the right to make changes at any time, without notice, in design, materials, specifications, and prices, and also to discontinue colors, styles and products.
Ein wichtiger Punkt beim Kauf des Geräts Superior VF5000-CMP-2 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Superior VF5000-CMP-2 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Superior VF5000-CMP-2 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Superior VF5000-CMP-2 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Superior VF5000-CMP-2 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Superior VF5000-CMP-2 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Superior VF5000-CMP-2 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Superior VF5000-CMP-2. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Superior VF5000-CMP-2 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.