Benutzeranleitung / Produktwartung SLDVT-40PM des Produzenten Superior
Zur Seite of 32
SLDVT Direct - Vent Gas Fireplaces INST ALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. INST ALLA TEUR : Laissez cette notice avec l'appareil. CONSOMMA TEUR : Conservez cette notice pour consultation ultérieure.
2 S af et y an d Y o u r F i r e p l a c e T o prevent severe burns and injuries, install a screen or physical barrier to prevent direct contact with the glass.
3 Afin d'éviter de vous brûler gravement ou de vous blesser , installez une grille ou une barrière physique pour empêcher tout contact direct avec la vitre. P ou r co mm a n de r un P AN N E AU D E PR O T E C TI ON L en no x ® G R A T UI T po ur v ot re fo ye r , c o ns ul t e z l es d é t ai ls d an s l a p ar t ie g a u ch e.
4 Important Safety Information 1. WARNING: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person . 2. Do not use this appliance if any part has been under water .
5 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. A PP OS IT I ON D ES MI SE S E N GA RD E R EL A TI VE S À L A SÉ C UR IT É D ’U TI LI S A TI O N V ot re fo ye r a ét é l iv ré av ec d es ét iq ue tt es d e sé c ur it é qu i d oi ve nt êt re co ll ée s à cô té de s d is po si t if s de co nt rô le d u fo ye r .
6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Appliance Installation, Service, and Maintenance Notices IMPORT ANT : Improper installation, adjustment, alteration, service, or main- tenance can cause injury or property damage. Refer to this manual.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. GENERAL INFORMA TION The fireplace models covered in this manual are direct-vent sealed combustion gas fireplace heaters designed for residential application. These direct-vent appliances operate with the combustion chamber completely isolated from the indoor environment.
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS Gas Controls/Control Compartment Access The gas con trols can be fou nd behind the control compartment access door .
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS Figure 3 - SIT.
10 SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS MAINTENANCE (See Maintenance Schedule, Page 26 ) R ef er to t he m a in te na nc e s c he du le fo r ma in te na nc e ta sk s, pr oc ed ure s, p er io di ci ty an d b y w ho m th ey sh ou ld be pe rfo rm ed .
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS Figure 6 Fron.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS Figure 7 4. Placement of Glowing Embers - Separate the Embers (rockwool) into pieces about the size of a quarter (see Figure 8 ) .
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS SLDVT -30 AND.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS SLDVT -40 LOG.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS SLDVT -45 LOG.
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS BURNER ADJUST.
17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. W ARNINGS • Air shutter adjustment should only be performed by a quali- fied professional ser vice technician. • Ensure front glass panel are in place and sealed during adjustment. CAUTIONS • Carbon will be produced if the air shutter is closed too much.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS TP-TH TP TH O.
19 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. ACCESSORY COMPONENTS Remote Control Kit, Standard Cat. No. Model No. Description H0249 RCL Remote Control System (Standard) Remote Control Kit, Deluxe Cat.
20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Barrier Screen Panel Kit This easy to install optional screen panel installs over the standard glass enclosure panel and provides a barrier to prevent direct contact with the hot glass surface. These screen panels cannot be used in conjunction with the arch door kits or door frame kits.
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Bag of Glowing Embers Bag of Volcanic Stone Replacement ember materials or volcanic stone are available for use with these appliances. Order kits as part of the periodic maintenance of the appliance.
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS LIGHTING INSTRUCTIONS – MILLIVOL T GAS V AL VE FOR YOUR SAFETY READ BEFORE LIGHTING A.
23 SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS REMARQUE : LES SCHÉMAS ET LES ILLUSTRA TIONS NE SONT PAS À L ’.
24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS A. When lighting the appliance, follow these instructions exactly .
25 REMARQUE : LES SCHÉMAS ET LES ILLUSTRA TIONS NE SONT PAS À L ’ÉCHELLE INSTRUCTIONS D’ALLUMAGE — ELECTRONIC INSTRUCTIONS D’ALLUMAGE PO UR V OT RE SÉ CU RI TÉ , LI SE Z CE S IN ST RU CT IO NS A VA NT L ’A LL UM AG E A. Lorsque vous allumez l’appareil, suivez exactement ces instruc- tions.
26 SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS MAINTENANCE T ASK ACCOMPLISHING PERSON PROCEDURE Inspecting/Cleaning Burner , Logs and Controls Qualified Service T echnician Inspect valve and ensure it is properly operating.
27 SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark igniter will not light pilot after repeated triggering of igniter button.
28 SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Check voltage on AC terminals of module an/or batteries.
29 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. REPLACEMENT P ARTS LIST Gas Controls - SIT Millivolt Item No. Description Natural Gas Propane Gas Part No.
30 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS REPLACEMENT P ARTS Dexen Gas Controls SIT Gas Controls 6 10 29 9 7 28 16 17 18 19 15 7 10 (Ref.
31 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Notes SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS.
32 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SU PER IOR ® D IRE CT -V ENT GA S F IRE PLA CES • M ODE LS SLD VT -3 0/3 5/4 0/4 5 • CAR E A ND OPE RA TI ON INS TRU CTI ONS Printed in U.S.A. © 2009/2011 Lennox Hearth Products P/N 506010-01 Rev .
Ein wichtiger Punkt beim Kauf des Geräts Superior SLDVT-40PM (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Superior SLDVT-40PM noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Superior SLDVT-40PM - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Superior SLDVT-40PM reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Superior SLDVT-40PM erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Superior SLDVT-40PM besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Superior SLDVT-40PM verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Superior SLDVT-40PM. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Superior SLDVT-40PM gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.