NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 1 Unvented Decorative Gas Fireplaces P/N 904538 REV. E 02/2004 CF5500-CMN CF6500-CMN CF5500-CMP CF6500-CMP MODELS ST ANDARD SERIES INST ALLA TION INSTRUCTIONS FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM HEATERS.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 2 Check the inventory list to be sure that you have all the necessary parts in usable condition. Also check for concealed damage. IMPORTANT SAFETY INFORMATION INSTALLER: PLEASE LEAVE THESE INSTRUC- TIONS WITH THE OWNER.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 The National Fuel Gas Code defines a con- fined space as a space whose volume is less than 50 ft 3 per 1,000 BTU/Hr (4.8 m 3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 ft 3 per 1,000 BTU/Hr (4.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 3. Add the BTU/hr of all the fuel burning appli- ances in the space. Vent-Free heater (Max.) ______ BTU/hr Gas appliance #1* ______ BTU/hr Gas applian.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 5 WARNING: DO NOT INSTALL THESE APPLIANCES: • WHERE CURTAINS, FURNITURE, CLOTHING OR OTHER FLAMMABLE OBJECTS ARE LESS THAN 42" FROM THE FRONT OF THE UNVENTED ROOM HEATER. • IN HIGH TRAFFIC AREAS.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 6 Note: Framing dimensions in Figures 4 - 9 are calculated for a nailing flange depth of ¹⁄₂ " (13 mm). Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Step 3 . Remove the nailing flanges from the lower control compartment and install in place with three (3) screws each.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 7 The gas control valve is located in the lower control compartment. To access the valve open the lower control compartment door ( Figure 13 ). The control valve has a ³⁄₈ " NPT thread inlet port and is fitted with a 3" (76 mm) long nipple, ³⁄₈ " NPT on both ends.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 8 Figure 16 Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be ganged wired to the same terminal that the pre-wired black wire is attached to and the white supply wire must be connected to the opposite side of the outlet.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 9 Figure 18 Step 10. Checking the System – After the gas line is installed, logs are in place and the system is leak checked, run initial system checkout before closing up the front of the unit. Follow the pilot lighting instructions on pages 16 and 17.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 10 Rear Burner Flames – The rear flames rising in front of center and rear logs should be yellow and extend about 2 ¹⁄₂ – 3" above the large logs for natural gas and 1 ¹⁄₂ – 2 ¹⁄₂ ” above for propane gas.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 11 The appliances covered in this manual are heater rated and produce a great deal of heat. Decorative brass trim pieces and hoods may tarnish because of their proximity to the heater opening and front face.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 12 8. CAUTION: DO NOT OPERATE THIS APPLI- ANCE WITH A BROKEN GLASS PANEL. Where broken glass exists, the complete glass enclo- sure panel must be replaced. See the Replace- ment Parts List on page 18 for correct replace- ment part numbers.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 13 Cleaning and Servicing WARNING: TURN OFF THE APPLIANCE AND ALLOW TO COOL BEFORE CLEAN- ING. WARNING: ALWAYS TURN OFF THE GAS SUPPLY TO THE PILOT BEFORE CLEAN- ING. BEFORE RE-LIGHTING, REFER TO THE LIGHTING INSTRUCTIONS IN THIS MANUAL.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 14 ACCESSORIES AND COMPONENTS Forced Air Kit FAB-1100 Remote Control Kit RCK Rocker Switch Kit RS VF5-BRLK Brass Louver Kits VF6-BRLK 1-Piece Decorative.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 15 CF5500 SPECIFICATIONS Figure 28 CF6500 SPECIFICATIONS Figure 29 37" (940 mm) 36" (914 mm) 30" (762 mm) 31 ¹⁄₂ " (800 mm) 15&.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 16 TROUBLESHOOTING THE CF MILLIVOL T GAS CONTROL SYSTEM 1. Spark ignitor will not light pilot after repeated triggering of black button. 2. Pilot will not stay lit after carefully following the lighting instructions.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 17 LIGHTING INSTRUCTIONS – MILLIVOLT WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY READ BEFORE LIGHTING • Do not use any phone in your building.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 18 REPLACEMENT PARTS LIST — MILLIVOLT GAS CONTROLS — MILLIVOLT CF5500-CMN CF5500-CMP CF6500-CMN CF6500-CMP CF5500-CMN CF5500-CMP CF6500-CMN CF6500-CMP No. DESCRIPTION Part No. Qty. Part No. Qty. Part No.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 19 REPLACEMENT PARTS 12 5 2 4 2 1 6 7 21 3 20 13 7 22 24 23 8 11 10 9 b. a. c. d. (SIT Valve Shown).
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 20 Printed in U.S.A. © 1999 by SFC P/N 904538 REV. E 02/2004 Catalytic Gas Fireplace Manufacturer's Limited Warranty 10 Y ears THE WARRANTY The manufacturer warrants the components of this Catalytic Gas Fireplace manufactured by SFC, INC.
Ein wichtiger Punkt beim Kauf des Geräts Superior CF6500-CMP (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Superior CF6500-CMP noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Superior CF6500-CMP - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Superior CF6500-CMP reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Superior CF6500-CMP erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Superior CF6500-CMP besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Superior CF6500-CMP verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Superior CF6500-CMP. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Superior CF6500-CMP gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.