Benutzeranleitung / Produktwartung B-40REP des Produzenten Superior
Zur Seite of 16
1 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INST ALLA TION INSTRUCTIONS ST ANDARD SERIES 36" B-VENTED GAS APPLIANCES P/N 700,003M REV. H 05/2004 Millivolt Models Electronic Models B-40RMN B-40REN B-40RMP B-40REP RET AIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WH Report No.
2 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TABLE OF CONTENTS Introduction ..................................... page 2 General Information ......................... page 2 Location .......................................... page 3 Clearances .
3 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea.
4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Venting Gas Vent Rule – Gas vent caps are not permit- ted within 8 feet (2.4 mm) of a vertical wall or similar obstruction.
5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. A 38 ¹⁄₂ " 978 mm B 33 ³⁄₄ " 857 mm C 28 ³⁄₁₆ " 716 mm D 14" 356 mm E 55" 1397 mm F 27 ¹⁄₂ " 699 .
6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 10 Note: Refer to the vent manufacturers installa- tion instructions for variations of venting tech- niques. If common venting of several units is contemplated, it should be discussed with an architect and the local Building Department.
7 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 13 Figure 14 Figure 12 Figure 15 Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resis- tant compounds are used in propane applica- tions). Turn on gas supply and test for gas leaks using a soapy water solution.
8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. WARNING: DO NOT REMOVE THE AC- TUATOR ARM LOCKING SCREW UNLESS THE COMPLETE OUTSIDE AIR VENT SYS- TEM HAS BEEN INSTALLED IN ACCOR- DANCE WITH THE DETAILED INSTRUC- TIONS PROVIDED WITH THE KIT.
9 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 19 Figure 20 When first lighting the appliance, it will take a few minutes for the line to purge itself of air. Once purging is complete, the pilot and burner will light and operate as indicated in the in- struction manual.
10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. When satisfied that the appliance operates prop- erly, proceed to finish the installation. Leave the control knob/lever in “ ON ” position and turn the remote switch “ OFF. ” Replace the refractory access panel.
11 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTALLATION ACCESSORIES The following accessory items are available for use in the installation of this appliance. Outside Air Kits Models FOAK-4 and FOAK-4LD Outside Air kits are available with duct (FOAK-4) and without duct (FOAK-4LD) for use if outside combustion air is required or desired.
12 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. In Canada THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.1 AND .2 INSTALLATION CODE.
13 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 29 Pilot Orifice Step 6. All Millivolt Systems – Attach ma- nometer to the manifold side pressure test fitting and verify manifold pressure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.
14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE..
15 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE..
16 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Printed in U.S.A. © 2002 by Lennox Hearth Products P/N 700,003M REV. H 05/2004 LHP 1110 West Taft Avenue • Orange, CA 92865 The manufacturer rese.
Ein wichtiger Punkt beim Kauf des Geräts Superior B-40REP (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Superior B-40REP noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Superior B-40REP - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Superior B-40REP reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Superior B-40REP erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Superior B-40REP besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Superior B-40REP verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Superior B-40REP. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Superior B-40REP gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.