Benutzeranleitung / Produktwartung Huntingdon 30 des Produzenten Stovax
Zur Seite of 23
H u n t i n g d o n 3 0 C o a l E f f e c t S t o v e C on v en t io n al F l ue With upgradeable control valve I ns t r uc t io n s f or U se , I ns t a ll a ti o n a nd S er v i ci n g Fo r use i n G B, IE (G re at Br it ain a nd Ei re ) PR0928 Issue 1 (June 2007) IMPORTANT Do not attempt to burn rubbish in this fire.
2 CONTENTS COVERING THE FOLLOWING MODELS HUNTINGDON 30 8503CFMCUC P8503CFMCUC PAGE APPLIANCE COMMISIONING CHECKLIST 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 8 Technical Specifications 8 Site Re.
3 FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test 3. Spillage test GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full 4.
1.1 A competent person must carry out installation and servicing. 1.2 In all correspondence, please quote the appliance type and serial number, which can be found on the databadge located on a plate under the appliance.
5 4.2 STANDARD REMOTE CONTROL This remote control can control the gas appliance after the pilot has been lit. It can turn the main burner on and regulate it from low through to high and back again. It can turn the main burner off leaving the pilot burning GAZCO PART NUMBER 8455.
6 USER INSTRUCTIONS ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS The fuel effect and side panels in this appliance are made from Refractory Ceramic Fibre (RCF), a material which is commonly used for this application.
7 7.1 Ensure the rope seal fitted to the rear of the glass frame is intact. • Use a ceramic glass product generally sold for cleaning ceramic hobs to clean the glass front • Refit glass frame and .
8 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION Covering the following models 8575MCUC - P8575MCUC Model Gas Gas Working NOX Aeration Injector Gas Rate Input kW (Gross) Country CAT. Type Pressure Class m 3 /h High Low Huntingdon 30 I 2H Natural Gas 20 mbar 5 1 x 7.
9 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1.1 The chimney or flue system must comply with the rules in force, and must be a minimum of 127mm in diameter. (5"). 1.2 The minimum flue height for the appliance must be 3 metres (10ft). Any horizontal flue run from the rear outlet must not exceed 100mm from the back of the appliance.
minimum of 10 minutes must be allowed before trying to relight. If this safety device is continually shuts off the gas it can suggest a serious problem: • Contact Gazco 2.8 Do not alter or tamper with the Flue Sure System. Use only genuine Gazco replacement parts when servicing the system - refer to the Servicing Section, Replacing Parts .
11 INSTALLATION INSTRUCTIONS INSTALLATION 3.5 The flue system can now be connected to the stove: • Ensure all joints are sealed with a suitable fire resident sealant.
12 • Place the front coal between the heat shield and the flame baffle so that its ends sit flat against the burner skin Diagram 9 • Put five of the round coals on the front between the fingers of the flame baffle.
13 • Now replace top, Diagram 15 5.1 Full instructions are given in the User Section . 6. LIGHTING 15 AR1907 14 AR1908 INSTALLATION INSTRUCTIONS INSTALLATION.
14 INSTALLATION INSTRUCTIONS COMMISSIONING • Close all openable doors and windows in the room • Ignite the stove and operate on maximum for 10 minutes • Remove the plastic sight plug from the ri.
15 IGNITION FUNCTIONAL CHECK 1 PILOT WILL NOT LIGHT Ensure there is no debris around the pilot assembly, (e.g. soot, etc.) which could short the spark, clean the area. Operate the valve. Is there a spark? Consult Section 2 and retry. Check alignment of pilot burner head, change the ignition lead, see diagram 1 on page 17.
16 PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE Ensure there is no debris around the pilot assembly, e.g. coal, soot etc. which could short the spark, clean the area. Problem is with the pipework or fittings which lead to the fire. Correct and retry.
17 2.4 Remove the two screws at the back of the firebox and lift the burner unit clear Diagram 3 3.1 • Follow the procedure for removing the main burner When the burner is out: • Remove the aeration cover by undoing the two screws, Diagram 4 • Remove the lint arrester, by folding the tabs back Diagram 5 AR1444 5 AR1443 4 AR1442 3 1.
18 The pilot unit can now be removed by undoing the two screws, Diagram 6 3.2 • Reassemble in reverse order • Do not overtighten. NOTE: TAKE CARE NOT TO DISCONNECTTHE SENSOR WIRES OF THE GAZCO FLUE SURE SYSTEM ON REPLACING THE THERMOCOUPLE 4.
19 6.2 There is a small cylindrical metal spacer inside the cover, this must be kept and replaced on the fixing screw during re-assembly • Disconnect the ignition lead from the gas valve • Undo th.
20 9.1 • Open the door and remove the ceramics, placing them carefully to one side. • Undo the two screws in the back of the firebox and carefully withdraw the bracket, Diagram 14 and 15 9.2 • Disconnect the two sensor wires • Undo the two taptite screws • Remove the sensor and the two plastic spacers, Diagram 16 9.
NG LPG COMPONENT G20 G31 20mb 37mb MAIN INJECTOR IN0001 IN0054 AERATION PLATE ME4066 ME4954 PILOT INJECTOR PI0036 PI0037 BURNER ASSEMBLY B0214 PB0214 THERMOCOUPLE PI0010 MAGNETIC UNIT GC0092 ELECTRODE.
22 SERVICE RECORDS 1ST SERVICE 2ND SERVICE Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Next Service due: . . . . . . . . . . . . . . .
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Tel: (01392) 261999 Fax: (01392) 444148 E-mail: info@gazco.com A member of the Stovax Group.
Ein wichtiger Punkt beim Kauf des Geräts Stovax Huntingdon 30 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Stovax Huntingdon 30 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Stovax Huntingdon 30 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Stovax Huntingdon 30 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Stovax Huntingdon 30 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Stovax Huntingdon 30 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Stovax Huntingdon 30 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Stovax Huntingdon 30. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Stovax Huntingdon 30 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.