Benutzeranleitung / Produktwartung 8545LUC, P8545LUC des Produzenten Stovax
Zur Seite of 27
C l a r e n d o n & A s h d o n L o g E f f e c t S t o v e R a n g e B al a nc e d F lu e With upgradeable control valve I ns t r uc t io n s f or Us e , I ns t a ll a ti o n a nd Se r v ic i ng Fo r use in GB , IE (G rea t Bri ta in and Ei re ) PR0847 Issue 2 (February 2007) I M P O R T A N T Do not attempt to burn rubbish in this fire.
2 CONTENTS COVERING THE FOLLOWING MODELS ASHDON - 8546LUC - P8546LUC / 8544LUC - P8544LUC CLARENDON 8545LUC - P8545LUC / 8547LUC - P8547LUC PAGE APPLIANCE COMMISIONING CHECKLIST 3 USER INSTRUCTIONS 4 .
3 FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test N/A 3. Spillage test N/A GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full MTM fires only.
4 USER INSTRUCTIONS 1. GENERAL 1.1 Installation and servicing must be carried out by a competent person. 1.2 In all correspondence, please quote the appliance type and serial number which can be found on the data badge located at the rear of the stove.
7.2 Place log B on the left hand side of the burner with the location bar on the underside of the log fully located in the long slot of the burner. Make sure the log is as far to the left as possible.
6 7.4 Place log D across from the rear log A to log B on the left- hand side. There are cut-outs in both logs for location. See diagram 5. 7.5 There are two ash panels which lay across the front of the burner skin. Place the panel with the flat edge facing the left side of the firebox.
8. THE FLAME FAILURE DEVICE 8.1 This is a safety feature incorporated in all GAZCO fires which automatically switches off the gas supply if the pilot light goes out and fails to heat the thermocouple.
8 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION COVERING THE FOLLOWING MODELS: ASHDON - 8546LUC - P8546LUC / 8544LUC - P8544LUC CLARENDON - 8545LUC - P8545LUC / 8547LUC - P8547LUC Model Gas Gas Working Aeration Injector Gas Rate Input kW (Gross) Country CAT.
9 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1. FLUE AND CHIMNEY REQUIREMENTS NOTE: This appliance can only be installed in conjunction with the flue supplied. 1.1 The flue must be sited in accordance with BS5440: Part 1 (latest editon). See diagram 1.
10 1.2 REAR FLUE 8526 Terminal dimensions: 395 x 200 x 200 mm (H x W x D) Cut to length as required on site. Guard Supplied. 1.3 TOP EXIT Two types of top exit flue terminal are available, horizontal and vertical.
11 1.5 TOP FLUE UP & OUT WITH ADDITIONAL BEND Any additional bend may be used on the horizontal section (either 45° or 90°) but the overall horizontal flue run will be reduced. Refer to diagram 4. 1.6 TOP FLUE VERTICAL KIT (8524/8524AN) - ALL APPLIANCES Vertical from the top of the appliance.
12 2. VENTILATION The appliance requires no additional ventilation. 3. INSTALLATION OF THE GAS SUPPLY 3.1 Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible.
13 IMPORTANT: ENSURE THAT THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF USE. REFER TO DATABADGE AND TECHNICAL SPECIFICATIONS OF THIS BOOKLET. FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SECTION 10, REPLACING PARTS.
14 3.1.5 To set the flue length, measure the total wall thickness, then add 65mm. This total flue length will give the minimum clearance of 50mm between the rear of the stove and the wall. To cut the flue to length using a hacksaw, first insert the square cardboard fitment into the flue.
15 INSTALLATION INSTRUCTIONS INSTALLATION 3.2 TOP EXIT 3.2.1 There are two types of top exit flues available, one with a vertical terminal, the other with a horizontal terminal. Minimum and maximum flue lengths are shown in Diagram 3 under Site Requirements, 1.
3.3 TOP EXIT - VERTICAL FLUE 3.3.1 If a vertical only flue system has been purchased refer to Site Requirements, Diagram 5. The following areas need careful consideration:- a) Terminal positions b) Flue supports c) Weatherproofing d) Fire precautions For all of the above, local and national codes of practice must be adhered to.
17 INSTALLATION INSTRUCTIONS INSTALLATION 5. FUELBED ARRANGEMENTS Remove the cast iron door using the tool provided. The main ceramic components are inside the firebox. NOTE: THE CAST IRON DOOR IS HEAVY, TAKE EXTREME CARE WHEN HANDLING TO AVOID DAMAGING THE OUTER CASING.
5.4 Place the second ash panel to the right of the first, with the pointed end of the panel fitting into the V shape. This panel should locate on the screw holes of the burner skin. Ensure that both logs are horizontal to the burner ports. 5.5 Place log E across from the rear of log A to log C on the right hand side.
1. COMMISSIONING 1.1 Having run the gas supply to the stove, PURGE THE SUPPLY PIPE, this is essential to expel any debris that may block the gas controls. Connect the gas supply to the 8mm compression elbow at the RH rear corner of the stove, see diagram 1.
20 1. SERVICING REQUIREMENTS This appliance must be serviced at least once a year by a competent person. All tests must be serviced by best practice as described by the current CORGI recommendations.
21 SERVICING INSTRUCTIONS SERVICING / FAULT FINDING CHARTS NO SPARK IGNITION FUNCTIONAL CHECK 2 Ensure there is no debris around the pilot assembly, (e.g. coal, soot etc.) which could short the spark, clear the area. From Ignition Fault Finding Chart Part 1.
22 SERVICING INSTRUCTIONS REPLACING PARTS 1. GENERAL 1.1 All principal components can be replaced without removing the stove from its installation, although it is essential that the gas supply to the appliance is turned off at the isolation device before proceeding further.
23 SERVICING INSTRUCTIONS REPLACING PARTS 3.4 To remove the pilot injector, undo the compression nut on the pilot feed pipe and withdraw the injector which will be hooked onto the olive. When replacing an injector always make sure it is hooked onto the olive before inserting it into the pilot burner.
24 SERVICING INSTRUCTIONS REPLACING PARTS 4.3 To release the right hand side of the control cover insert the narrow blade screwdriver into the slot shown in diagram 9.
25 SERVICING INSTRUCTIONS REPLACING PARTS 8.4 Holding the injector with a spanner, undo the feed pipe. NOTE: THE ORIENTATION OF THE INJECTOR. 8.5 Reassemble in reverse order, turn on the gas supply and check for any leaks. 9. PRIMARY AERATION PLATE 9.
26 SERVICE RECORDS 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:................................
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Tel: (01392) 261999 Fax: (01392) 444148 E-mail: info@gazco.com A member of the Stovax Group.
Ein wichtiger Punkt beim Kauf des Geräts Stovax 8545LUC, P8545LUC (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Stovax 8545LUC, P8545LUC noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Stovax 8545LUC, P8545LUC - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Stovax 8545LUC, P8545LUC reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Stovax 8545LUC, P8545LUC erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Stovax 8545LUC, P8545LUC besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Stovax 8545LUC, P8545LUC verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Stovax 8545LUC, P8545LUC. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Stovax 8545LUC, P8545LUC gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.