Benutzeranleitung / Produktwartung DP90 des Produzenten Barco
Zur Seite of 22
Co oling liquid r efur bishme nt Installation manual For XLM, DP90 and DP100 R59770032/01 07/12/2006.
Barco nv Eve nts Noordl aan 5, B-8520 Kuurne Phone: +32 56.36.89.70 Fax: +32 56.36.88.24 E-mail: sales.events@barco.com Visit us at the web: www.barco.
1. Liquid C ooling Circ uit 1. LIQUID COOLING CIRCUIT Overview • Safety • Introduction • Diagnostics 1.1 Safety W ARNING : Hazardous pr oduct: Blue a ntifree ze dilu ted 1,2 et hanedio l (1/3 eth anediol – 2/3 Demi water). Not for household use.
1. Liqui d Cooling Ci rcuit Parts of the liquid cooling circui t A B C H G F I K J D E Image 1-1 A DMD - Peltier cooling block. B Manometer . C Pressure vessel. D Outlet cooling circuit E Inlet cooling circuit F V ane GP u m p . H Cooling block light pipe entrance.
1. Liquid C ooling Circ uit Block d iagram o f the coo ling circu it Engine Pump Vane Outlet Inlet Expansion Vat Manometer Heat Exchanger Light Pipe entry Pressure relief valve (3 Bar) Vane Outlet Inl.
1. Liqui d Cooling Ci rcuit T o oh i g ha m b i e n tt e m p e r a t u r e An Error or warning message “Ambient temp high” is displayed on the local LCD pa nel or touch panel. See manual of the projector for accessing error messages. Possible cause Solution Ambient temperature of the projector is too high.
1. Liquid C ooling Circ uit Possible cause Solution Defect pump. When the projector is running, you don’t feel any vibrations when touching the pump Drain the liquid cooling circuit, replace the pump, fill and pressurize the liquid cooling circuit. T i p: It’ s not ne cessary to drain the cooling circuit of the light processor .
1. Liqui d Cooling Ci rcuit 6 R59770032 COOLING LIQU ID REFURBISHMENT 07/12/2006.
2. Servicing the liquid cooling circ uit 2. SER VICING T HE LIQUID COOLING CIRCUIT W ARNING : All procedures in this chapter may on ly be performed by “qualifie d service technicians” .
2. Servicing the liquid coo ling circuit 2.1 Preparation for cooling liquid replacement What has to be done 1. Switch off the projector . 2. Remove the lamp unit to access the cooling liquid in- and outlet. 3. If excluding the light processor is required w hile handling the co oling circuit procedures, disconnect the circuit at the flow switch (a).
2. Servicing t he liquid coolin g circuit OUT Image 2-3 Drain complete circui t 2. Close the valve. 3. Fill the syringe with air . Press in the valve of the male fitting when extracting air . Image 2-4 4. Couple the air filled syringe to the inlet of the cooling circuit and force air into the circuit via the syringe.
2. Servicing the liquid coo ling circuit 2.3 Filling the liq uid cooling circu it This procedure can only be used to fill an e mpty (drained) coo ling circuit. Necessary t ools • 60 cm of plastic tube with male valved fitting. • 60 cm of plastic tube with fe male valved fitting.
2. Servicing t he liquid coolin g circuit ab c d e f M F Image 2-7 4. Couple the filled syringe to the inlet of the cooling circuit and press the cooling liquid inside the circuit. Caution: Position the empty bottle above the liquid circuit (on top of projector).
2. Servicing the liquid coo ling circuit 2.4 Refreshing the liquid cooling circuit Over time the cool ing liquid may show d eterioration and hen ce less effective cooling ch aracteristics. T o m ain- tain sound cooling properties, we advise ANNUAL replac ement of the cooling liquid.
2. Servicing t he liquid coolin g circuit OUT IN Image 2- 10 Refresh cooling circ uit 5. Switch on the projector . After projector boot-up procedure, the in ternal pump will automatically start sucking-up the fresh liquid Note: Make sure that the end of the plastic tube remains immersed in the bottle with fresh cooling liquid.
2. Servicing the liquid coo ling circuit b ac d M F F M Image 2-1 1 Caution: It’s important that there is no air i nside the tube. The pump is not self priming and hence i s only capable of sucking through small volumes of air. 3. Push the male valved fitting of the filled tube into the inlet of the cooling circuit.
2. Servicing t he liquid coolin g circuit 7. Uncouple the two plastic tubes. Note: Make sure that both ends of the plastic tubes in the bottle remains immersed until the plastic tubes are uncouple from the li quid c ooli ng cir cuit . Tip : Sometimes a little cooling liquid will be spilled.
2. Servicing the liquid coo ling circuit ab c d e f M F Image 2- 13 2. Couple the syringe to the inlet of the cooling circuit and press t he cooling liquid inside the circuit until the manom eter indicates 1 bar pressure. Ensure that no air bubbles are injected into the circuit.
2. Servicing t he liquid coolin g circuit Check within 24 hours whether th e pressure has stabilized close to 1 bar . If not, search for leak age. 2.7 Calibrating the liquid cooling circuit T o check .
2. Servicing the liquid coo ling circuit ab c d e f M F Image 2- 16 3. Fill the pressure vessel with liquid as follows: a) Couple the syringe with the inlet of the cooling circuit. b) Increase the pressure by pushing in the piston of the syringe (maximum 1 bar indi cated on the m anometer).
2. Servicing t he liquid coolin g circuit 4. Now that the pressure vessel is liquid filled you have to increase the pressure to 1 bar by pushing in the piston of the syringe. Then immediately extract 75 ml back into the syringe by doing the following: a) T aking note of the liquid level already in the syringe, release the plunger .
2. Servicing the liquid coo ling circuit The air hose fitting of the air pump mu st be of the Shrader valve type (A) to match with the pressure vessel, so the Presta valve type (B) has to be removed. Futhermore, the pin (C) inside the Shrader valve has to be removed as well.
Ein wichtiger Punkt beim Kauf des Geräts Barco DP90 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Barco DP90 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Barco DP90 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Barco DP90 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Barco DP90 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Barco DP90 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Barco DP90 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Barco DP90. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Barco DP90 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.