Benutzeranleitung / Produktwartung VPL-FX51 des Produzenten Sony
Zur Seite of 34
DATA PROJECTOR VPL-PX35 DATA PROJECTOR VPL-PX40 DATA PROJECTOR VPL-FX51 PROTOCOL MANUAL 1st Edition (Revised 3).
VPL-PX35/PX40/FX51 ! W ARNING This manual is intended f or qualified ser vice personnel only . T o reduce the risk of electr ic shock, fire or injury , do not perf or m any ser vicing other than that contained in the operating instructions unless you are qualified to do so.
1 VPL-PX35/PX40/FX51 Table of Contents 1. Introduction .............................................................................................. 1 2. RS-232C 2-1. Communication Specifications ......................................................
2 VPL-PX35/PX40/FX51 Appendix A. Setup Method For VPL-PX35 and PX40 A-1. Command ..................................................................................................... 18 A-1-1. Setting ..................................................
1 VPL-PX35/PX40/FX51 EVEN Parity.....Total number of “1”s from D0 to D7 is an even number. D4 D5 D6 D7 (MSB) (LSB) (EVEN) BIT PARITY STOP BIT START D3 D2 D1 D0 1. Introduction This protocol manual describes the basic configuration and basic operations of various commands used for projector.
2 VPL-PX35/PX40/FX51 2-2. Command Block Format The code from B0 to B7 as described below are transmitted. START CODE : 0 x A9 B0 B1 B2 B4 B3 DATA ITEM NUMBER ACK / NAK ITEM NUMBER SET / GET ACK DUMMY .
3 VPL-PX35/PX40/FX51 2-3. Block Format START CODE B0 B1 B2 B4 B3 DATA ITEM NUMBER SET / GET CHECK SUM END CODE B5 B6 B7 START CODE B0 B1 B2 B4 B3 DUMMY DATA ACK / NAK ACK CHECK SUM END CODE B5 B6 B7 S.
4 VPL-PX35/PX40/FX51 2-5. Communication Procedure 2-5-1. Outline of Communication All communication between CONTROLLER (PC, etc.) and DEVICE (PROJECTOR) is performed by the command block format. Communication is started by the issue of a command at CONTROLLER and ended when the return Data is sent to CONTROLLER after DEVICE receives the command.
5 VPL-PX35/PX40/FX51 2-6. Communication Rules . When sending a command from CONTROLLER, the return Data from PROJECTOR should be received first before sending the next command. Even if the next command is sent before receiving the return Data, since PROJECTOR will not be able to receive that command, it does not return a response to CONTROLLER.
6 VPL-PX35/PX40/FX51 3. NETWORK 3-1. Introduction This section describes the specifications, performance and operations of the network service that is going to be installed in the target projector.
7 VPL-PX35/PX40/FX51 3-1-2. Remote Control The remote control service is provided that can control the target equipment from remote location via network. The SDCP protocol that serves to acquire the basic information such as equipment name and serial numbers is installed in this projector.
8 VPL-PX35/PX40/FX51 3-2. SDAP Protocol This section describes the SDAP packet structure. Fig.1 Packet structure 1) Header The header consists of ID (16 bit), version (8 bit) and category (8 bits). Fig. 2 Header ID It is fixed to “ DA ” . Version This indicates the version number of protocol.
9 VPL-PX35/PX40/FX51 3-3. SDCP Protocol This section describes the packet structure of version 2. Fig. 1 Packet structure 3-3-1. Format 3-3-1-1. Header The header consists of Version (8 bits) and Category (8 bits). Fig. 2 Header structure Version This indicates the version number of protocol.
10 VPL-PX35/PX40/FX51 3-3-1-3. Command This section describes the format of the request command and the response command. (1) Request This section describes the format of the request command that is issued from the host PC to the projector.
11 VPL-PX35/PX40/FX51 00h Item No. n Set Data (n byte) Request Item No. Data Length Data OK (01h) Item No. 0 3-3-1-4. SET Request The SET request is used to set a new value in the specified item. Details of the request and the response are described below.
12 VPL-PX35/PX40/FX51 3-3-2. Items Category Contents SET GET 00**h Used to control and to change the various setups. OO 01**h Used to acquire the status. O 03**h Used to reset memory. O 17**h Sircs (15 bit category) O 19**h Sircs (20 bit category) O 80**h Used to acquire equipment information.
13 VPL-PX35/PX40/FX51 3-3-2-3. Network Information Acquisition (90**h) Used to acquire the network setup information. Lower bytes Contents SET GET 00h MAC Address O 01h IP Address O 02h Subnet Mask O .
14 VPL-PX35/PX40/FX51 3-3-3. Error Code The error code list is shown below with a detailed description of each. Category Error Error Code Item Error (01**h) Invalid Item 01h Invalid Item Request 02h I.
15 VPL-PX35/PX40/FX51 3-3-3-1. Item Error This error occurs when the Item No. of a request is illegal or its Data is illegal. The conditions for occur- rence of the respective errors are shown below. Invalid Item An unsupported Item No. is specified. Example 1: The unsupported category 0xA ** is specified.
16 VPL-PX35/PX40/FX51 3-3-3-3. Request Error This error occurs when Header or Command is illegal. The conditions of occurrence of the respective errors are shown below. Invalid Version The version of the Header is other than 2. n When another version is supported, an error occurs in all versions other than the supported version.
17 VPL-PX35/PX40/FX51 3-3-3-5. Comm Error This is an error in communication with the main control microprocessor of the display. Timeout Reception Data is not returned after Data is sent. Check Sum Error A check sum error occurred in the main control microprocessor of the display.
18 VPL-PX35/PX40/FX51 Appendix A. Setup Method For VPL-PX35 and PX40 Establishing the network setup such as IP address can be implemented from the PC browser, and the information such as installation location can be viewed on the PC browser. A-1. Command A-1-1.
19 VPL-PX35/PX40/FX51 A-1-2. Display Enter the following command using the format shown below in a browser as URL, and then value of the setting item is displayed. Format http://IP address/Item IP address The IP address that is assigned to the network block Item Name of the setup item Response The following HTML is returned.
20 VPL-PX35/PX40/FX51 A-2. Setting Command Each setting item is described below. Equipment information Item Description Default location Sets location of the equipment installation. (Maximum 24 alphanumeric characters) _ Community Sets the equipment community.
21 VPL-PX35/PX40/FX51 <Table 1> <Table 2> Item Number Data Remarks Item Upper byte Lower byte Data Upper byte Lower byte VIDEO 00h 00h Set/Get S VIDEO 00h 01h INPUT 00h 01h INPUT A 00h 02h.
22 VPL-PX35/PX40/FX51 <Table 1> <Table 2> Item Number Data Remarks Item Upper byte Lower byte Data Upper byte Lower byte STANBY 00h 00h Get only START UP 00h 01h STARTUP LAMP 00h 02h POWER.
23 VPL-PX35/PX40/FX51 (VPL-PX35, PX40) <Table 1> <Table 2> Item Number Data Remarks Item Upper byte Lower byte Data Upper byte Lower byte Input 00h 01h Video 00h 00h Set/Get S-Video 00h 01.
24 VPL-PX35/PX40/FX51 <Table 1> <Table 2> Item Number Data Remarks Item Upper byte Lower byte Data Upper byte Lower byte STATUS ERROR 01h 01h NO ERROR 00h 00h Get only LAMP ERROR 00h 01h F.
25 VPL-PX35/PX40/FX51 List of SIRCS CODE (1) 15BIT Category (VPL-FX51 only) <Table 4> POWER ON/OF HUE + PURPLISH HUE _ GREENISH SHARPNESS + SHARP SHARPNESS _ SOFT ADJ R ADJ G ADJ B W/B GAIN W/B .
26 VPL-PX35/PX40/FX51 (2) 20BIT Category (VPL-FX51 only) <Table 5> x0 0x 1x 2x 3x 4x 5x 6x 7x x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF APA DOT PHASE LENS ZOOM LENS SHIFT LENS FOCUS FREEZE LE.
27 VPL-PX35/PX40/FX51 (3) 15BIT Category (VPL-PX35, PX40) <Table 6> POWER ON/OF AUDIO MUTING VOLUME- DOWN VOLUME+ UP HUE + PURPLISH HUE _ GREENISH SHARPNESS + SHARP ADJ G ADJ R ADJ B W/B GAIN W/.
28 VPL-PX35/PX40/FX51 (4) 20BIT Category (VPL-PX35, PX40) <Table 7> x0 0x 1x 2x 3x 4x 5x 6x 7x x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF APA DOT PHASE FREEZE LENS CONT TOGGLE DIGITAL ZOOM + V.
VPL-PX35/PX40/FX51 The material contained in this manual consists of inf or mation that is the proper ty of Sony Cor poration. Sony Corporation e xpressly prohibits the duplication of any portion of t.
Printed in Japan Son y Cor por ation 2003. 4 16 B&P Company ©2002 VPL-PX35 (SY) VPL-PX40 (SY) VPL-FX51 (SY) E 9-870-346-64.
Ein wichtiger Punkt beim Kauf des Geräts Sony VPL-FX51 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Sony VPL-FX51 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Sony VPL-FX51 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Sony VPL-FX51 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Sony VPL-FX51 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Sony VPL-FX51 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Sony VPL-FX51 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Sony VPL-FX51. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Sony VPL-FX51 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.