Benutzeranleitung / Produktwartung I-7011 des Produzenten B&B Electronics
Zur Seite of 64
1 I-701 1, I-7018 User M a nual Rev:B1.0 W arra nty All products ma nufa ctured by ICP DAS are warra nted against defective materi als for a period of one year from the date of delivery to the original purcha ser . W arning ICP DAS a ssume no li a bility for da mage s consequent to the use of this product.
2 I-701 1, I-7018 User M a nual Rev:B1.0 T a ble of Contents 1. Intr oduction ..................................................... 5 1.1 More Inf ormation ....................................... 5 1.2 Pin Assignment ..................................
3 I-701 1, I-7018 User M a nual Rev:B1.0 2.1 1 $AA6 ..................................................... 3 2 2.12 $AA8 ..................................................... 3 3 2.13 $AA8V .................................................. 3 4 2.14 $AA9(Data) .
4 I-701 1, I-7018 User M a nual Rev:B1.0 2.35 ~AA2 ..................................................... 5 7 2.36 ~AA3EVV ............................................. 5 8 2.37 ~AA4 ..................................................... 5 9 2.38 ~AA5PPSS .
5 I-701 1, I-7018 User M a nual Rev:B1.0 1. Intr oduction I-7000 is a fa mily of network data a cquisition a nd control modules. They provide a nalog-to-digital, digital-to-a nalog, digital input/output, ti mer/counter a nd other functions. These module s ca n be re mote controlled by a set of comma nds.
6 I-701 1, I-7018 User M a nual Rev:B1.0 1.2 Pin Assignment.
7 I-701 1, I-7018 User M a nual Rev:B1.0.
8 I-701 1, I-7018 User M a nual Rev:B1.0 1.3 Spe cifications I-701 1/I-701 1D Analog Input Input Cha nnel : 1 Input T ype : mV , V , mA(with external 125 ohms resistor) Thermocouple : T ype J, K, T , E, R, S, B, N, C Sa mpling Rate : 10 Sa mples/Second Ba ndwidth : 5.
9 I-701 1, I-7018 User M a nual Rev:B1.0 I-701 1P/I-701 1PD Analog Input Input Cha nnel : 1 Input T ype : mV , V , mA(with external 125 ohms resistor) Thermocouple : T ype J, K, T , E, R, S, B, N, C, L, M Sa mpling Rate : 10 Sa mples/Second Ba ndwidth : 5.
10 I-701 1, I-7018 User M a nual Rev:B1.0 I-7018 Analog Input Input Cha nnel : 8 diff erenti al or 6 diff eren- ti al a nd 2 single-ended. Jumper select. Input T ype : mV , V , mA(with external 125 ohms resistor) Thermocouple : T ype J, K, T , E, R, S, B, N, C Sa mpling Rate : 10 Sa mples/Second Ba ndwidth : 15.
11 I-701 1, I-7018 User M a nual Rev:B1.0 1.4 Block Di agra m.
12 I-701 1, I-7018 User M a nual Rev:B1.0 I-7018/18P Analog Input Cha n- nel 0 to 5 W ire Connection 1.5 W ir e Connection I-701 1/1 1D/1 1P/1 1PD Analog Input W ire Connection I-701 1/1 1D/1 1P/1 1PD.
13 I-701 1, I-7018 User M a nual Rev:B1.0 I-7018/18P Analog Input Cha n- nel 6 a nd 7 W ire Connection, while the jumper JP1 setting is 8 diff erenti al mode. I-7018/18P Analog Input Cha n- nel 6 a nd 7 W ire Connection, while the jumper JP1 setting is INIT* mode.
14 I-701 1, I-7018 User M a nual Rev:B1.0 1.6 Quick Start Re f er to “ I-7000 Bus Converter User M a nual ” a nd “ Get- ting Start ” for more detail. 1.7 Default Setting Default setting f or I-701 1/1 1D/1 1P/1 1PD/18/18P : z Address : 01 z Analog Input T ype : T ype 05, -2.
15 I-701 1, I-7018 User M a nual Rev:B1.0 1.9 Cali bration Don’t Perf orm Calibrate U ntil Y ou Re ally U ndersta nd. Calibration Require ment for I-701 1/1 1D/1 1P/1 1PD/18/18P Notification : 1 While calibrate type 06, need connect external shunt resistor , 125 ohms, 0.
16 I-701 1, I-7018 User M a nual Rev:B1.0 1.10 Configuration T a ble s Configuration T a ble of I-701 1/1 1D/1 1P/1 1PD/18/18P : Baudrate Setting (CC) Analog Input T ype Setting (TT) T .
17 I-701 1, I-7018 User M a nual Rev:B1.0 Ty p e Co d e I nput R a ng e D a t a Fo rm a t + F . S . Z e ro - F . S . 00 - 15 t o +15 mV E n g i n eer U n i t +15.000 +00.000 - 15.000 % of FSR +100.00 +000.00 - 100.00 2's com pl em en t H E X 7FF F 0000 8000 01 - 50 t o +50 mV E n g i n eer U n i t +50.
18 I-701 1, I-7018 User M a nual Rev:B1.0.
19 I-701 1, I-7018 User M a nual Rev:B1.0 Ty p e Co d e I nput R a ng e D a t a Fo rm a t + F . S . Z e ro - F . S . 16 C T y pe 0 t o 2320 deg ree C el si u s E n g i n eer U n i t +2320.
20 I-701 1, I-7018 User M a nual Rev:B1.0 2. Comma nd Comma nd Format : (Lea ding)(Addr e ss)(Comma nd)[CHK](cr) Response Format : (Lea ding)(Addre ss)(Data)[CHK](cr) [CHK] 2-chara cter checksum (cr) .
21 I-701 1, I-7018 User M a nual Rev:B1.0 Ge n e r a l C o m m an d S e ts (Con tin u e d ) ~ A AO (Data) !AA S et Mod u l e N am e Sec .2.19 ~ A A E V ! A A E n a b le / D is a b le C a lib r a t io n Sec .
22 I-701 1, I-7018 User M a nual Rev:B1.0 2.1 %AANNTTCCFF De scri ption : Set module Configuration Syntax : %AANNTTCCFF[CHK](cr) % a deli miter chara cter A A a ddress of setting module(00 to FF) N N new a ddress for setting module(00 to FF) T T new type for setting module (Ref Sec.
23 I-701 1, I-7018 User M a nual Rev:B1.0 2.2 #** De scri ption : Synchronized Sa mpling Syntax : #**[CHK](cr) # a deli miter chara cter ** synchronized sa mpling comma nd Re sponse : No response Exa mple : Comma nd : $014 Rece ive : ?01 Rea d synchronized sa mpling data, return no data valid.
24 I-701 1, I-7018 User M a nual Rev:B1.0 2.3 #AA De scri ption : Rea d Analog Input Syntax : #AA[CHK](cr) # deli miter chara cter A A a ddress of rea ding module(00 to FF) Re sponse : V alid Comma nd : >(Data)[CHK](cr) Syntax error or communication error may get no re- sponse.
25 I-701 1, I-7018 User M a nual Rev:B1.0 2.4 #AAN De scri ption : Rea d Analog Input from cha nnel N Syntax : #AAN[CHK](cr) # deli miter chara cter A A a ddress of rea ding module (00 to FF) N cha nn.
26 I-701 1, I-7018 User M a nual Rev:B1.0 2.5 $AA0 De scri ption : Perf orm Spa n Calibration Syntax : $AA0[CHK](cr) $ deli miter chara cter A A a ddress of setting module (00 to FF) 0 comma nd for pe.
27 I-701 1, I-7018 User M a nual Rev:B1.0 2.6 $AA1 De scri ption : Perf orm Zero Calibration Syntax : $AA1[CHK](cr) $ deli miter chara cter A A a ddress of setting module (00 to FF) 1 comma nd f or pe.
28 I-701 1, I-7018 User M a nual Rev:B1.0 2.7 $AA2 De scri ption : Rea d Configuration Syntax : $AA2[CHK](cr) $ deli miter chara cter A A a ddress of rea ding module (00 to FF) 2 comma nd for rea ding.
29 I-701 1, I-7018 User M a nual Rev:B1.0 2.8 $AA3 De scri ption : Rea d CJC T e mperature Syntax : $AA3[CHK](cr) $ deli miter chara cter A A a ddress of rea ding module (00 to FF) 3 comma nd f or rea.
30 I-701 1, I-7018 User M a nual Rev:B1.0 2.9 $AA4 De scri ption : Rea d Synchronized Data Syntax : $AA4[CHK](cr) $ deli miter chara cter A A a ddress of rea ding module (00 to FF) 4 comma nd for rea .
31 I-701 1, I-7018 User M a nual Rev:B1.0 2.10 $AA5VV De scri ption : Set Cha nnel Ena ble Syntax : $AA5VV[CHK](cr) $ deli miter chara cter A A a ddress of setting module (00 to FF) 5 comma nd f or settting cha nnel ena ble V V cha nnel ena ble/disa ble, 00 is all disa bled, a nd FF is all ena bled.
32 I-701 1, I-7018 User M a nual Rev:B1.0 2.1 1 $AA6 De scri ption : Rea d Cha nnel Status Syntax : $AA6[CHK](cr) $ deli miter chara cter A A a ddress of rea ding module (00 to FF) 6 comma nd for rea .
33 I-701 1, I-7018 User M a nual Rev:B1.0 2.12 $AA8 De scri ption : Rea d LED Configuration Syntax : $AA8[CHK](cr) $ deli miter chara cter A A a ddress of rea ding module (00 to FF) 8 comma nd f or se.
34 I-701 1, I-7018 User M a nual Rev:B1.0 2.13 $AA8V De scri ption : Set LED Configuration Syntax : $AA8V[CHK](cr) $ deli miter chara cter A A a ddress of setting module (00 to FF) 8 comma nd for sett.
35 I-701 1, I-7018 User M a nual Rev:B1.0 2.14 $AA9(Data) De scri ption : Set CJC Offset V alue Syntax : $AA9(Data)[CHK](cr) $ deli miter chara cter A A a ddress of setting module (00 to FF) 9 comma nd f or setting CJC of fset value (Data) CJC of fset value comprise s a sign a nd 4 hexa deci mal digits, from -1000 to +1000, ea ch count is 0.
36 I-701 1, I-7018 User M a nual Rev:B1.0 2.15 $AAB De scri ption : Thre mocouple Open Detection Syntax : $AAB[CHK](cr) $ deli miter chara cter A A a ddress of rea ding module (00 to FF) B comma nd f .
37 I-701 1, I-7018 User M a nual Rev:B1.0 2.16 $AAF De scri ption : Rea d Firmware V ersion Syntax : $AAF[CHK](cr) $ deli miter chara cter A A a ddress of rea ding module (00 to FF) F comma nd for rea.
38 I-701 1, I-7018 User M a nual Rev:B1.0 2.17 $AAM De scri ption : Rea d Module Na me Syntax : $AAM[CHK](cr) $ deli miter chara cter A A a ddress of rea ding module (00 to FF) M comma nd f or rea din.
39 I-701 1, I-7018 User M a nual Rev:B1.0 2.18 $AAZ(Data) De scri ption : Set LED Data Syntax : $AAZ(Data)[CHK](cr) $ deli miter chara cter A A a ddress of setting module (00 to FF) Z comma nd for setting LED data (Data) data for show on the LED, from -19999.
40 I-701 1, I-7018 User M a nual Rev:B1.0 2.19 ~AAO(Data) De scri ption : Set Module Na m e Syntax : ~AAO(Data)[CHK](cr) ~ deli miter chara cter A A a ddress of setting module (00 to FF) O comma nd f .
41 I-701 1, I-7018 User M a nual Rev:B1.0 2.20 ~AAEV De scri ption : Ena ble/Disa ble Calibration Syntax : ~AAEV[CHK](cr) ~ deli miter chara cter A A a ddress of setting module (00 to FF) E comma nd f.
42 I-701 1, I-7018 User M a nual Rev:B1.0 2.21 @AADI De scri ption : Rea d Digital I/O a nd Alarm Status Syntax : @AADI[CHK](cr) @ deli miter chara cter A A a ddress of rea ding module (00 to FF) D I .
43 I-701 1, I-7018 User M a nual Rev:B1.0 high. Related Comma nd : Sec.2.22 @AADO(Data), Set.2.23 @AAEA T , Sec.2.26 @AADA Related T opic : Sec.3.4 Digital Input a nd Event Counter , Sec.
44 I-701 1, I-7018 User M a nual Rev:B1.0 2.22 @AADO(Data) De scri ption : Set Digital Output Syntax : @AADI[CHK](cr) @ deli miter chara cter A A a ddress of setting module (00 to FF) D O comma nd f o.
45 I-701 1, I-7018 User M a nual Rev:B1.0 2.23 @AAEA T De scri ption : Ena ble Alarm Syntax : @AAEA T[CHK](cr) @ deli miter chara cter A A a ddress of setting module (00 to FF) EA comma nd f or ena ble alarm. T alarm type, M=momentary alarm, L=latch alarm.
46 I-701 1, I-7018 User M a nual Rev:B1.0 2.24 @AAHI(Data) De scri ption : Set High Alarm Syntax : @AADI[CHK](cr) @ deli miter chara cter A A a ddress of setting module (00 to FF) H I comma nd for setting high alarm value (Data) high alarm values, data format is in engineer unit format.
47 I-701 1, I-7018 User M a nual Rev:B1.0 2.25 @AALO(Data) De scri ption : Set Low Alarm Syntax : @AADI[CHK](cr) @ deli miter chara cter A A a ddress of setting module (00 to FF) LO comma nd f or setting high alarm value (Data) high alarm values, data format is in engineer unit format.
48 I-701 1, I-7018 User M a nual Rev:B1.0 2.26 @AADA De scri ption : Disa ble Alarm Syntax : @AADA[CHK](cr) @ deli miter chara cter A A a ddress of setting module (00 to FF) D A comma nd for disa ble alarm Re sponse : V alid Comma nd : !AA[CHK](cr) Invalid Comma nd : ?AA[CHK](cr) Syntax error or communication error may get no re- sponse.
49 I-701 1, I-7018 User M a nual Rev:B1.0 2.27 @AACA De scri ption : Clear Latch Alarm Syntax : @AACA[CHK](cr) @ deli miter chara cter A A a ddress of setting module (00 to FF) C A comma nd f or clear latch alarm Re sponse : V alid Comma nd : !AA[CHK](cr) Invalid Comma nd : ?AA[CHK](cr) Syntax error or communication error may get no re- sponse.
50 I-701 1, I-7018 User M a nual Rev:B1.0 2.28 @AARH De scri ption : Rea d High Alarm Syntax : @AARH[CHK](cr) @ deli miter chara cter A A a ddress of rea ding module (00 to FF) R H comma nd for rea di.
51 I-701 1, I-7018 User M a nual Rev:B1.0 2.29 @AARL De scri ption : Rea d Low Alarm Syntax : @AARH[CHK](cr) @ deli miter chara cter A A a ddress of rea ding module (00 to FF) R L comma nd f or rea di.
52 I-701 1, I-7018 User M a nual Rev:B1.0 2.30 @AARE De scri ption : Rea d Event Counter Syntax : @AARE[CHK](cr) @ deli miter chara cter A A a ddress of rea ding module (00 to FF) R E comma nd for rea.
53 I-701 1, I-7018 User M a nual Rev:B1.0 2.31 @AACE De scri ption : Clear Event Counter Syntax : @AACE[CHK](cr) @ deli miter chara cter A A a ddress of setting module (00 to FF) C E comma nd for clear event counter Re sponse : V alid Comma nd : !AA[CHK](cr) Invalid Comma nd : ?AA[CHK](cr) Syntax error or communication error may get no re- sponse.
54 I-701 1, I-7018 User M a nual Rev:B1.0 2.32 ~** De scri ption : Host OK. Host sends this comma nd to all modules f or broa dca sting the infor - mation “Host OK”. Syntax : ~**[CHK](cr) ~ deli miter chara cter ** comma nd for all modules Re sponse : No response.
55 I-701 1, I-7018 User M a nual Rev:B1.0 2.33 ~AA0 De scri ption : Rea d Module Status Syntax : ~AA0[CHK](cr) ~ deli miter chara cter A A a ddress of rea ding module (00 to FF) 0 comma nd f or rea di.
56 I-701 1, I-7018 User M a nual Rev:B1.0 2.34 ~AA1 De scri ption : Reset Module Status Syntax : ~AA1[CHK](cr) ~ deli miter chara cter A A a ddress of setting module (00 to FF) 1 comma nd f or reset module status Re sponse : V alid Comma nd : !AA[CHK](cr) Invalid Comma nd : ?AA[CHK](cr) Syntax error or communication error may get no re- sponse.
57 I-701 1, I-7018 User M a nual Rev:B1.0 2.35 ~AA2 De scri ption : Rea d Host W atchdog T i meout Interval Syntax : ~AA2[CHK](cr) ~ deli miter chara cter A A a ddress of rea ding module (00 to FF) 2 .
58 I-701 1, I-7018 User M a nual Rev:B1.0 2.36 ~AA3EVV De scri ption : Set Host W atchdog T i meout Interval Syntax : ~AA3EVV[CHK](cr) ~ deli miter chara cter A A a ddress of setting module (00 to FF) 3 comma nd for set host watchdog ti meout interval E 1=Ena ble/0=Disa ble host watchdog V V ti meout value, from 01 to FF , ea ch for 0.
59 I-701 1, I-7018 User M a nual Rev:B1.0 2.37 ~AA4 De scri ption : Rea d PowerOn V alue a nd Safe V alue Syntax : ~AA4[CHK](cr) ~ deli miter chara cter A A a ddress of rea ding module (00 to FF) 4 co.
60 I-701 1, I-7018 User M a nual Rev:B1.0 2.38 ~AA5PPSS De scri ption : Set PowerOn V alue a nd Saf e V alue Syntax : ~AA5PPSS[CHK](cr) ~ deli miter chara cter A A a ddress of setting module (00 to FF.
61 I-701 1, I-7018 User M a nual Rev:B1.0 3. Application Note 3.1 INIT* pin Operation Ea ch I-7000 module ha s a build-in EEPROM to store con- figuration information such a s a ddress, type, baudrate a nd other information. Someti m es, user may for get the configuration of the module.
62 I-701 1, I-7018 User M a nual Rev:B1.0 3.3 Dual W atchdog Operation Dual W atchdog = Module W atchdog + Host W atchdog The Module W atchdog is a hardware reset circuit to moni- tor the module’s operating status. While working in harsh or noisy environment, the module may be down by the external signal.
63 I-701 1, I-7018 User M a nual Rev:B1.0 3.6 High/Low Alarm Some a nalog input modules, like I-701 1, equi p with the high/low alarm function. When the alarm function is ena bled, the digital output .
64 I-701 1, I-7018 User M a nual Rev:B1.0 T o mea sure the Seebeck voltage directly is not availa ble because we must first connect a voltmeter to the thermocouple, a nd the voltmeter lea ds the mselves create a new thermoelectric circuit.
Ein wichtiger Punkt beim Kauf des Geräts B&B Electronics I-7011 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie B&B Electronics I-7011 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für B&B Electronics I-7011 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von B&B Electronics I-7011 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über B&B Electronics I-7011 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon B&B Electronics I-7011 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von B&B Electronics I-7011 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit B&B Electronics I-7011. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei B&B Electronics I-7011 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.