Benutzeranleitung / Produktwartung PGF75-3 des Produzenten Smeg
Zur Seite of 16
Summary 1 INSTRUCTIONS FOR SAFE AND PROPER USE _______________ 20 2 POSITIONING OF THE HOB _______________________________ 22 3 ADJUSTMENT TO DIFFERENT TYPES OF GAS _______________ 28 4 FINAL OPERATIO.
Introduction 1 INSTR UCTIONS FOR SAFE AND PR OPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS EN TIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE HOB. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE HOB.
Introduction THE APPLIANCE DATA PLATE, WITH TECHNICAL DATA, REGISTRATION NUMBER AND BRAND NAME, IS POSITIONED AT A VISIBLE POINT UNDER THE SAFETY COVER. THE DATA PLATE ON THE PROTECTIVE COVER MUST NEVER BE REMOVED . DO NOT PUT PANS WITHOUT PERFECTLY PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE HOB PANSTAND GRIDS.
Instructions for the installer 22 2 POSITIONING OF THE HOB The following operation requires buildi ng and/or carpentry work so must be carried out by a competent tradesman. Installation can be carried out on various materials such as masonry, metal, solid wood or plastic laminat ed wood, as long as they are heat- resistant (T 90°C).
Instructions for the installer 2.2 Attachment to support structure, flush-mounting model Create an opening with the dimensions shown in the figure in the work surface, observing a minimum distance of 50 mm from the rear edge. 1) The lower part of the protective cover must be fully accessible when the appliance is installed.
Instructions for the installer 24 Important: Other types of installation will only be possible under th e manufacturer's supervision. Overall dimensions: location of gas and electrical connection points (all measures in mm). Caution: surface temperature underneath may exceed 125 degrees C.
Instructions for the installer 2.3 Electrical connection Make sure that the voltage and capacit y of the power supply cable conform to the data shown on the plate loca ted under the protective cover.
Instructions for the installer 26 2.4 Ventilation requirements The appliance may be installed only in rooms with permanent ventilation, as required by standards regolations in force.
Instructions for the installer 2.6 Gas connection Connection to the gas mains may be made with a rigid copper pipe or with a flexible pipe conforming to the prov isions defined by standard regolations in force. After connection operations, check for leaks using a soapy solution.
Instructions for the installer 28 3 ADJUSTMENT T O DIFFERENT TYPES OF GAS Before performing any cleaning or maintenance work, unplug th e appliance from the mains.
Instructions for the installer 3.2 Burner and nozzle characteristics table Burner Rated heating capacity (kW) LPG – G30/G31 30/37 mbar Nozzle diameter 1/100 mm By-pass mm 1/100 Reduced flow rate (W) Flow rate g/h G30 Flow rate g/h G31 Auxiliary (1) 1.
Instructions for the installer 30 4 FINAL OPERA TIONS After carrying out the above adjustments, remount in reverse order to the instructions given in paragraph “3.
Instructions for the user 5 USING THE HOB 5.1 Ignition of the burners Before turning on the burners, make su re that the flame-spreader crowns and respective caps are properly fi tted in their housings. Ensure the flame-spreader holes A are aligned with the ignition plugs and the thermocouples.
Instructions for the user 32 5.2 Practical advice for using the burners For better use of the burners and lowe r gas consumption, use covered cooking receptacles that have a flat, smooth bottom and are proportional in size to the burner to prevent the flame from licking the sides (see paragraph “ 5.
Instructions for the user 6 CLEANING AND MAINTENANCE Before any intervention, disconnect the appliance from the mains. Never use a steam jet to clean the appliance. 6.1 Cleaning the stainless steel To keep stainless steel in good c ondition it should be cleaned regularly after use.
Instructions for the user 34 In models with central pan stand, fit this piece, taking care that its centre is perfectly aligned with the centre of the burner.
Ein wichtiger Punkt beim Kauf des Geräts Smeg PGF75-3 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Smeg PGF75-3 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Smeg PGF75-3 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Smeg PGF75-3 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Smeg PGF75-3 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Smeg PGF75-3 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Smeg PGF75-3 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Smeg PGF75-3. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Smeg PGF75-3 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.