AXIS T90B Series AXIS T90B15 W-LED AXIS T90B25 W-LED AXIS T90B35 W-LED AXIS T90B20 IR-LED AXIS T90B30 IR-LED AXIS T90B40 IR-LED E N G L I S H Installation Guide.
Legal Considerations Video and audio surveillance can be regulated by laws that vary from country to country . Check the laws in your local region before using this product for surveillance purposes. Liability Every care has been taken in the preparation of this document.
Australia/New Zealand This digital equipment fullls the requirements for RF emission according to the Class B limit of AS/NZS CISPR 22. The product shall be connected using a shielded network cable (STP) that is properly grounded.
.
AXIS T90B Series Safety Infor mation Read through this Installation Guide carefully before installing the product. Keep the Installation Guide for future reference. Hazard Levels DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury .
AXIS T90B Series Safety Instructions WARNING • The Axis product shall be installed by a trained professional. NO NO NO TICE TICE TICE • The Axis product shall be used in compliance with local laws and regulations. • Store the Axis product in a dry and ventilated environment.
AXIS T90B Series Installation Guide This Installation Guide provides instructions for installing AXIS T90B Series. Installation Steps 1. Make sure the package contents, tools and other materials necessary for the installation are in order . See page 7 .
AXIS T90B Series Hardware Overview Illuminator 1 2 3 1 Photocell 2 Cable 3 Breather gland 8.
AXIS T90B Series 1 2 3 4 5 6 1 P ower cable (red) 2 P ower cable (black) 3 Photocell cable (white) 4 Photocell cable (yellow) 5 Telemetry cable (purple) 6 Telemetry cable (orange) 9 E N G L I S H.
AXIS T90B Series 1 2 3 4 5 1 Red LED indicator 2 Amber LED indicator 3 Green LED indicator 4 Remote control receiver 5 Mounting bracket (pre-mounted) 1 0.
AXIS T90B Series AXIS T90B40 IR-LED 1 2 3 1 Cables 2 Mounting bracket (pre-mounted) 3 Bolt Optional Accessories Remote Control For information how to use the remote control, see Access the Product .
AXIS T90B Series 1 2 3 4 5 6 7 8 9 1 POWER ADJUST buttons 2 PHOT OCELL ADJUST buttons 3 TIMER buttons 4 Photocell disable button 5 DIM button 6 RESET button 7 STA TUS button 8 Disable remote control s.
AXIS T90B Series LED Indicators There are three colored LED indicators on the base of the illuminator which provide operating and status information. The color status depends on the current operating .
AXIS T90B Series Normal Operating Mode (Continued) Solid Amber Input voltage level error* Solid Red Internal LED error *Once the voltage error has been corrected, disable the remote control setup or restart the illuminator to turn the status LED off. Connectors and Buttons For specications and operating conditions, see page 14 .
AXIS T90B Series AXIS T90B25 W-LED 12–24 V AC/DC, max 24 W AXIS T90B30 IR-LED 12–24 V AC/DC, max 48 W AXIS T90B35 W-LED 12–24 V AC/DC, max 48 W AXIS T90B40 IR-LED 12–24 V AC/DC, max 96 W For m.
AXIS T90B Series CAUTION IR emitted from this product. Avoid prolonged eye exposure or use appropriate shielding or eye protection at distances of less than 1.5 m. Follow these installation procedures: 1. If required, remove the screws and move the standard bracket to the top of the illuminator .
AXIS T90B Series 3. If required, loosen the screws and change to a diverging lens with the desired angle of illumination. The angle of illumination should be adjusted according to the camera eld of view to light the whole scene adequately . See Technical Specications .
AXIS T90B Series 2 1 1 Screws 2 Diverging lens Note Adjust the vertical position of the illuminator to ensure that the eld of view of the camera is illuminated.
AXIS T90B Series 4. P osition the illuminator adjacent to the camera and point the illuminator towards the scene. CAUTION Red cable = +ve, Black cable = - ve (polarity sensitive) 5. Mount the power supply . 6. Connect the illuminator to the power supply .
AXIS T90B Series 2 3 1 1 Illuminator 2 P ower cable 3 P ower supply 7. Set photocell following output (White & Y ellow) V olt free output — normally open (day) to normally closed (night). Connect direct to camera if required to control switchover of day/night cameras.
AXIS T90B Series • Telemetry TEL enabled • Telemetry input wires soldered together for automatic photocell operation • Telemetry DIM disabled • LED status indicators enabled • Programming Mode Note Changing the settings requires a remote control (optional accessory).
AXIS T90B Series P ower Adjust The power output of the illuminator can be adjusted between ve pre-set levels. Select the required light intensity by using the buttons below .
AXIS T90B Series There are three pre-dened levels to set the lux level threshold at which the photocell turns the illuminator on or off. Select the required sensitivity level by using the buttons below .
AXIS T90B Series V olt-free input: Non polarity sensitive Short circuit = Light on TTL input: Orange = TTL +ve Purple = TTL - ve (GND) 0 V = Light on 3 V = Light off The telemetry input wires (orange .
AXIS T90B Series 1. Turn the light on (night) and off (day) automatically via the photocell. This is the standard factory setting, no further action is required. 2. Turn the light on and off from a remote switch or input. 3. Used in conjunction with the Timer Function to turn the light on for a pre-dened period of time.
AXIS T90B Series If you wish to cancel the timer period and have the illuminator operate under standard telemetry conditions, press Timer Disabled. 1 2 3 4 5 6 1 Timer disabled 2 1 minute 3 3 minutes .
AXIS T90B Series Factory Default Note To activate this feature the button must be pressed continuously for 4 seconds. This is to avoid the possibility of activating this feature accidentally . Once the illuminator has been programmed, the settings will be stored in a non-volatile (stored) memory .
AXIS T90B Series • Basics - Check the LED status indicator . See LED Indicators . - Check polarity of lamp connection: red = +ve, black = -ve - Ensure power is 12-24 V AC or DC - Ensure telemetry wires are shorted out or closed contact input (zero volt) is applied - Check photocell is working.
AXIS T90B Series • Remote Control (optional accessory) - Press the ST ATUS button to check the status of the remote control, see LED Status Indicators . - Programming may be disabled. Turn the illuminator power off for at least 1 0 seconds and then turn the power on to enter Programming Mode.
AXIS T90B Series P ower Input V oltage: 12-24 V AC/DC AC Frequenzy: 50-60 Hz Cable length 2.5 m (8 ft) P ower Consumption maximum light / 20% of maximum light / Standby mode: AXIS T90B15 W-LED: 12 W / 3 W / 0.15 W AXIS T90B25 W-LED: 24 W / 6 W / 0.15 W AXIS T90B35 W-LED: 48 W / 12 W / 0.
AXIS T90B Series Distance AXIS T90B20 IR-LED 1 0°x10° - 120 m (394 ft)* 35°x1 0° - 65 m (2 13 ft) 60°x25° - 45 m (148 ft) 80°x30° - 30 m (98 ft) 120°x50° - 20 m (66 ft)** AXIS T90B30 IR-LED .
AXIS T90B Series 80°x30° - 30 m (98 ft) 120°x50° - 20 m (66 ft)** *No diverging lens **Optional accessory Casing Material: P olycarbonate IR-LED: Black W-LED: White and silver Display and indicato.
AXIS T90B Series Dimensions (HxWxL) The size of the product shall be maximum (WxHxL): AXIS T90B15 W-LED: 75 x 1 00 x 64 mm (3 x 4 x 2.5 in) AXIS T90B25 W-LED: 1 00 x 135 x 66 mm (4 x 5 x 2.5 in) AXIS T90B35 W-LED: 135 x 180 x 68,2 mm (5 x 7 x3.2 in) AXIS T90B20 IR-LED: 1 00 x 135 x 66 mm (4 x 5 x 2.
AXIS T90B Series Warranty Information For information about Axis’ product warranty and thereto related information, see www .axis.com/warranty/ 34.
35.
Installation Guide V er . M3.2 AXIS T90B Series Date: August 20 14 © Axis Communications AB, 20 14 P art No. 59 159.
Ein wichtiger Punkt beim Kauf des Geräts Axis Communications T90B40 IR-LED (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Axis Communications T90B40 IR-LED noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Axis Communications T90B40 IR-LED - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Axis Communications T90B40 IR-LED reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Axis Communications T90B40 IR-LED erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Axis Communications T90B40 IR-LED besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Axis Communications T90B40 IR-LED verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Axis Communications T90B40 IR-LED. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Axis Communications T90B40 IR-LED gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.