INSTRUCTION MANUA L Simrad RPU80/160/300 Reversible Pump www.Busse-Yachtshop.de email: info@busse-yachtshop.de.
Note! Simrad AS makes every effort to ensure that the information contained within this document is correct. However, our equipmen t is continuously being improved and updated, so we cannot assume liability for any errors which may occur.
Instruction Manual 20220422N 1 Instruction Manual This manual is intended as a reference guide for correctly installing and maintaining t he RPU80, RPU160 and RPU300 reversible pumps. Please take time to read this manual to get a thorough understanding of the reversible pump and its relationship to a complete autopilot system.
Simrad Reversible Pump RPU80/160/300 2 20220422N Document revisions Documentation department Hardware/Software design Project/Product Management Rev Date Sign Date Sign Date Sign D 24/10-96 N.G. 24/10-96 I.K. 24/10-96 Th.H. E 20/2-97 N.G. 20/2-97 I.K.
Instruction Manual 20220422N 3 Contents 1 INTRODUCTION .................................................................................................. 5 1.1 General....................................................................................
Simrad Reversible Pump RPU80/160/300 4 20220422N 7.8 When on automatic steering, the boat sw ings from side to side without stabilizing after course changes ............................................................................. 27 7.9 Small and sudden heading change s while on automatic steering .
Introduction 20220422N 5 1 INTRODUCTION Note ! This manual does not cover a previous model RPU80 with serial numbers 101-248. The model is covered by the RPU100 Reversible Pump Manual. Minor modifications where made to the RPU100 model and they are described in a separate "Technical Information" no.
Simrad Reversible Pump RPU80/160/300 6 20220422N An automatic "Rudder test" function in these autop ilots will also limit the output equ ivalent to a rudder speed of 8 degrees per second which is optimum for aut opilots with proportional rudder control.
Introduction 20220422N 7 1.2 Hydraulic steering gear suitable for the RPU80/RPU160/RPU300 All cylinders are single and balanced type unless otherw ise specified. If the cylinder type in your boat is not listed, please refer to section 2. Estimated rudder time in seconds hard over to hard over Steering gear Cylinder volume cm 3 (cu.
Simrad Reversible Pump RPU80/160/300 8 20220422N Estimated rudder time in seconds hard over to hard over Steering gear Cylinder volume cm 3 (cu.in.) RPU80 RPU160 RPU300 HYNAUTIC (con tinued) K-18 115 .
Introduction 20220422N 9 Estimated rudder time in seconds hard over to hard over Steering gear Cylinder volume cm 3 (cu.in.) RPU80 RPU160 RPU300 LECOMBLE & SCHMITT – Old models: VHM 32-DT 90 (5,.
Simrad Reversible Pump RPU80/160/300 10 20220422N Estimated rudder time in seconds hard over to hard over Steering gear Cylinder volume cm 3 (cu.in.) RPU80 RPU160 RPU300 SERVI (Norw egian) MA 60 141 (.
Introduction 20220422N 11 Estimated rudder time in seconds hard over to hard over Steering gear Cylinder volume cm 3 (cu.in.) RPU80 RPU160 RPU300 VETUS (continued) MT 225 500 (30, 5) 19 10 MT 340 750 .
Simrad Reversible Pump RPU80/160/300 12 20220422N 2 MEASUREMENTS AND CALCULATIONS FOR APPLYING THE RPU 2.1 Calculation of cylinder volume The RPU80 is recommended for cylinders between 80-250 cm 3 (4,9-15,2 cu. in.), RPU160 for cylinders between 160-550 cm 3 (9,8-33,5 cu.
Measurements and calculat ions for applying the RPU 20220422N 13 Recommended rudder time: 10-15 seconds is normal for a 70° (35°-0-35°) rudder angle. (The ti m e will be shorter for smaller angles and longer for larger angles.) A longer rudder time (20 sec.
Simrad Reversible Pump RPU80/160/300 14 20220422N 3 DESCRIPTION OF RPU80/RPU160/RPU300 3.1 Construction The pump comprises an electric perm anent magnet m otor, valve block with reversible gear pum p, non-return (ch eck) valves on outlet A and B and suction valves from both sides of the gear pump to outlet C.
Description of RPU80/RPU160/RPU300 20220422N 15 3.2 Principle of operation (ref. figure 3-1 and figure 9-1) RPU80/160/300 is reversible: that is the motor changes direction of rotation and the gear pump deliv ers oil to that side of the rudder cylinder dictated by the signal from the autopilot.
Simrad Reversible Pump RPU80/160/300 16 20220422N 3.3 Valve block This is an aluminum block with borings for no n-return valves, suction valves, slide, gear pump, motor coupling and all necessary oil ways. The three out lets A, B and C are positioned on top of the valve block.
Description of RPU80/RPU160/RPU300 20220422N 17 3.8 Pipe connections The 3 outlets have fittings for 3/8" (US model) or 10 mm (EU model) outer diameter pipe. The two outer outlets A and B connect to the main pipes. The middle outlet C connects to the bottom of the expansion tank in the steering wheel pump or a separate expansion tank.
Simrad Reversible Pump RPU80/160/300 18 20220422N O-ring European type fitting US type fitting Pump housi ng 4 INSTALLATION 4.1 Mechanical Installation Siting The pump unit should be sited where it is most practical between rudder cylinder and helm pump, however, it should not be mounted in a wet area.
Installation 20220422N 19 • Use the fingers and turn clockwise until a noticeable increase in torque is required. • Tighten further by 30 degrees (= 1/12 of a turn) using necessary force (25-30 Nm/230-260 In.Ibs). Pumps with new fittings have got new serial no.
Simrad Reversible Pump RPU80/160/300 20 20220422N A clearly formed lip should be visible on the pipe in front of the cutting ring. If this is not present, the nut should be tightened by an additional ½ - 1 turn. Check once again as above. From the T-couplings run a pipe 10x1 mm (US model: 3/8"), to the pump unit.
Installation 20220422N 21 Figure 4-5 Connection to hand hydraulic steering gear Drw.no. 3-110101 Figure 4-6 Connection to Capilano steering gear Drw.no.
Simrad Reversible Pump RPU80/160/300 22 20220422N 4.2 Electrical installation J3000X, J300X, J300X-40, J50, J50-40, AC10, AC20, AC40 The two leads from the motor are connected to the term inal block marked "MOTOR" in the Junction unit/Autopilot computer.
Installation 20220422N 23 5 PREPARATION AND TESTING 5.1 Oil filling and bleeding When installing a pump unit, it is recommended that the whole system be emptied and refilled. Use a well known oil of a viscosity meeting the specific ation of the steering gear manufacturer.
Simrad Reversible Pump RPU80/160/300 24 20220422N 6 MAINTENANCE 6.1 Dismantling After approximately 1000 operating hours, the pump unit should be removed for examination. Close the stop cocks to the pump unit, remove the nuts on the 3 couplings and all retaining nuts.
Fault tracing 20220422N 25 7 FAULT TRACING If fault develops, the so urce and location must be traced. Close all stop cocks to the pump unit and check whether the steering gear functions normally using only the steering wheel pump. If so, then the fault is most proba bly in the pum p unit or junction unit/autopilot computer.
Simrad Reversible Pump RPU80/160/300 26 20220422N 7.4 The rudder does not stay in off-midship position, but drifts towards midship due to water pressure on the rudder Probable reason (Does not apply for the previous model of RPU80): 1. The non-return valves are leaki ng.
Fault tracing 20220422N 27 7.7 Rudder movement stops as water pressure on the rudder increases. (J1000B, J101A, J45A only) Probable reasons: 1. Overload. Check whether the r.p.m . of the mo tor is too low. Eventually turn potentiome ter RV1 in junction unit clockwise (CW) until rudder m ovement is recovered.
Simrad Reversible Pump RPU80/160/300 28 20220422N 7.10 Rudder moves only in one direction (with pump running) Probable reason: Suction valve not working (pos. 20, 9, 21) on one side. This is most probably caused by metal fragments that have entered into the suction valve(s) through the tu be fitting for the return line (C) during installati on.
Technical Specifications 20220422N 29 8 TECHNICAL SPECIFICATION S 8.1 Specifications Note ! RPU300 measurements at charging voltage RAM CAPACITY MODEL MOTOR VOLTS * JUNCTION UNIT/ AUTOPILOT COMPUTER ** MIN cm 3 (cu. in.) MAX cm 3 (cu. in.) FLOW RATE AT 10 bar cm 3 /min (cu.
Simrad Reversible Pump RPU80/160/300 30 20220422N 8.2 Dimensions Figure 8-1 RPU80 Dimensions Drw.no. N3-111836 Figure 8-2 RPU160 Dimensions Drw.no. N3-111835 www.
Technical Specifications 20220422N 31 Figure 8-3 RPU300 Dimensions Drw.no. N3-111834 8.3 RPU80 performance AMPS 3 6 9 0.5 PRESSURE (BAR) CAPACITY (l/min) 1.0 1.5 0 10 20 30 40 50 60 0 Capacity versus pressure Current versus pressure www.Busse-Yachtshop.
Simrad Reversible Pump RPU80/160/300 32 20220422N 8.4 RPU160 performance AMP S 11 17 23 0.5 PRESSU RE (BAR) CAPAC IT Y (l/ min ) 1.0 1.5 0 10 20 3 0 40 50 60 5 2.0 Capacity versus pressure Current versus pressure 8.5 RPU300 performance* AMPS 10 15 20 PRESSURE (BAR) CAPACITY (l /min) 1.
Spare Parts 20220422N 33 9 SPARE PARTS 9.1 RPU80/RPU160/RPU300 Pos. Qty. Gear pump parts Part no. 1 1 Valve block 21100250 2 3 Fitting complete 7/16-20UNF 44166767 2 3 Fitting US model complete: Nut 3.
Simrad Reversible Pump RPU80/160/300 34 20220422N 13 2 O-r ing 9,25x1,7 8 Nitrile 4414964 9 14 2 Copp er washer Ø10,2x14x1,5 44149706 15 1 Oil seal 8x2 2x7 44149722 16 1 Support rin g 21100185 17 2 Copp er washer Ø10,2x14x1 44148146 18 1 O-ring 9,25x1,78 Silicon, red 44154656 20 2 Steel ball Ø6, 35 44118552 21 2 Grub.
Spare Parts 20220422N 35 9.2 RPU80 – Previous model gear pump RPU80 Reversible Pump with ser. no. 1317 H02 onwards (P/N 21116165) and 1805 H03 onwards (P/N 21116181 – US version) have identical gear pump with the RPU160 (see figure 9-1). Pos. Qty.
Simrad Reversible Pump RPU80/160/300 36 20220422N 10 SALES AND SERVICE WORLDWIDE 010304 EUROPE AUSTRIA Allroundmarin-Alltechnik GesmbH Rheinboldtstrasse 11-13 A-2362 Biedermannsdorf b.Wien Tel.: +43 2236 646 760 Fax: +43 2236 63135 www.allroundmarin.com BENELUX Simrad BV P.
Ein wichtiger Punkt beim Kauf des Geräts Simran RPU80 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Simran RPU80 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Simran RPU80 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Simran RPU80 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Simran RPU80 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Simran RPU80 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Simran RPU80 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Simran RPU80. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Simran RPU80 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.