Series 240/241 Instruction Manual Table of Contents Sierra Series 900 Single & Dual Channel System Instruction Manual Part Number IM- 90- 1 0 7 /0 5 Revision D.1 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 ht tp :/ / www.
Series 900 Single & Dual Instruction Manual Page 16 © COPYRIGHT SIERRA INSTRUMENTS 1994 No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval s.
Series 900 Single & Dual Instruction Manual Page 15 1 . Introduction ............................................................................. 1 2. Locating System Electronics .................................................. 2 3. Front Panel Functions .
Series 900 Single & Dual Instruction Manual Page 1 The Sierra Instruments, Inc. Single and Dual Channel System Electronics is a highly integrated systems solution to flow mea- surement and control. One or two independent flow meters or controllers can be operated simultaneously.
Series 900 Single & Dual Instruction Manual Page 2 The System Electronics should be located in a room-temperature location which is dry and dust-free. Use cable lengths in accor- dance with the guidelines given with your transducer. Excessive cable lengths will impair operation of both the System Electronics and the transducer.
Series 900 Single & Dual Instruction Manual Page 3 System Electronics’s front panel controls provide ease of opera- tion. To get the most benefit from a Sierra Instruments, Inc. System Electronics, read these instructions before attempting operation.
Series 900 Single & Dual Instruction Manual Page 4 As the potentiometer is rotated the appropriate alarm setpoint is varied from zero to the full scale flow value and displayed in the front LCD display. The totalize option records the total mass flow.
Series 900 Single & Dual Instruction Manual Page 5 The AC power line connector (or power entry module) is located on the back panel. A cordset is supplied with the System Electronics and is compatible with wall outlets in the USA.
Series 900 Single & Dual Instruction Manual Page 6 The VALVE PURGE function is activated by the VALVE TP (test point) pin. When this pin is connected to common, the valve is fully open regardless of setpoint. This pin must source 150 mA of current when driven to common.
Series 900 Single & Dual Instruction Manual Page 7 Normally each System Electronics is carefully set-up at Sierra Instruments and needs no maintenance. Individual transducers may need periodic maintenance. Refer to transducer manuals for the proper procedure.
Series 900 Single & Dual Instruction Manual Page 8 GENERAL System Electronics Powers/Reads up to two transducers. Flow, Setpoint, High Alarm, and Low Alarm directly displayed in engineering units. (Linear models). Outputs 0-5 volts and 4-20 mA for each channel.
Series 900 Single & Dual Instruction Manual Page 9 APPENDIX B Back Panel Connector Pin Assignments; 20-Pin Transducer Connector KEY ▼ (View of connector from back of enclosure) PIN NO.
Series 900 Single & Dual Instruction Manual Page 10 KEY ▼ APPENDIX C Back Panel Connector Pin Assignments; 26-Pin I/O Connector (View of connector from back of enclosure) PIN NO.
Series 900 Single & Dual Instruction Manual Page 11 The alarms are a normally, open collector transistor outputs; that is, a transistor is used as a switch to ground. A “High” alarm means that if the flow signal is higher than the alarm trip setting, the transistor will be turned on.
Series 900 Single & Dual Instruction Manual Page 12 APPENDIX E Wiring Guide.
Ra ti o C o n t ro l O p ti o n Appendix F T he con st ant ra t io -c ont r ol op t ion (“- RC” in th e m od el co de ), pr ov i de s th e use r wi t h t he ab i lit y to set an d m ai nt ai n an exa ct rat i o of ga s f lo w be t we en t wo (or mo re ) m ass fl ow con tr ol l er s (M F Cs) .
d. T urn of f t h e po we r swi t ch on th e f ro nt o f th e box, att a ch the cab l es and t he co ntr ol l er s (i f yo u h av en ’t alr ea dy do ne so ), an d t ur n t h e po we r o n. e. A pp l y gas pr es sur e to t he in let of t he con t ro l ler s per th e op er at i ng pre ss ur e li st e d on th e l ab el s.
Ein wichtiger Punkt beim Kauf des Geräts Sierra Not available (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Sierra Not available noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Sierra Not available - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Sierra Not available reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Sierra Not available erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Sierra Not available besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Sierra Not available verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Sierra Not available. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Sierra Not available gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.