Operating and installation instructions LB 23… LB 54… LB 75… 9000.018 538_Umschlag.qxd 26.08.2004 17:02 Uhr Seite 1.
Operating modes 2 Safe operation is possible provided that the underpressur e in the room wher e the burner is installed does not exceed 4 Pa (0.04 mbar).
3 Important notes: ❑ The Instructions for Use apply to several versions of this appliance. Accordingly , you may find descriptions of individual features that do not apply to your specific appliance. ❑ This extractor hood complies with all relevant safety r egulations.
4 The most effective method of r emo- ving vapours produced during cooking is to: ❑ Switch the ventilator ON as soon as you begin cooking. ❑ Switch the ventilator OFF a few minutes after you have finished cooking.
5 Filters and maintenance 2. Press the r etaining spring and remove the filter frame. 3. Remove the wire grille and r eplace the filter mat. 4. Install the filter frame in reverse sequence.
6 Filters and maintenance Extractor hoods with two filter cartridges: W arning: The halogen bulbs must be swit- ched off and cool. 1. Depress the detent on the gr ease filters in the direction of the arr ow and fold down the grease filter slightly . Detach the grease filter by pulling it towar ds yourself.
7 Activated carbon filter 5. Insert the activated carbon filter at the rear , fold up and lock in the middle with the wing nut. If the spacer rail has been removed, it must be r e-installed. 6. Re-insert the two filter cartridges. Removing the activated carbon filter: ❑ The activated carbon filter is removed in reverse sequence.
8 Cleaning and care Switch off the extractor hood and isola- te by pulling out the mains plug or swit- ching off the disconnector on the instal- lation side. ❑ At the same time as you renew the grease filter (see Filters and maintenance), clean off any gr ease from all accessible parts of the housing.
9 Halogen bulbs: 1. Switch off the extractor hood and isolate by pulling out the mains plug or swit- ching off the disconnector on the instal- lation side. When switched on, the halogen bulbs become very hot. Even for some time after the bulbs have been switched off ther e is still a risk of burns.
10 Old appliances are not worthless rubbish. V aluable raw materials can be reclaimed by r ecycling old appliances. Before disposing of your old appliance, render it unusable. Y ou received your new appliance in a protective shipping carton. All packaging materials are envir onmentally friendly and recyclable.
11 Exhaust-air mode The exhaust air is discharged upwards through a ventilation shaft or dir ectly through the outside wall into the open. D Exhaust air should neither be directed into a smoke or exha.
12 Optimum performance of the extractor hood: ❑ Short, smooth extraction pipe. ❑ As few pipe bends as possible. ❑ Largest possible pipe diameter (prefera- bly 150 mm ø) and large pipe bends. ❑ Round pipes: We r ecommend for single-motor model, inner diameter of at least 120 mm for double-motor model.
13 The extractor hood must be connected to a correctly installed earthed socket only . Attach the earthed socket as close to the appliance as possible and in an accessible position. If the earthed socket is no longer accessible following installation of the extractor hood, a disconnector must be provided on the installation side.
14 Extractor hood with slide control, 53 cm wide, 1 and 2-motor: 9 346 380 530 160 55 95 150 120 248 248 100 35 225 min 15 min 15 500 -3 16 35 2 -3 Extractor hood with slide control, 73 cm wide, 1 and.
15 1. Remove the filter grille (see operating instructions). 2. Connect the power . 3. Press the extractor hood up into the installation opening until the installation aid locks into position at the front and rear . 4. Screw in the extractor hood. 5. Insert and secure the filter grille (see operating instructions).
9000 018538 Printed in Germany 0904 Hi. Siemens Elektrogeräte GmbH 280 530 280 530 280 530 380 530/730 380 530/730 LZ 72040 LZ 23000 LZ 73040 LZ 73050 461423 481051 095660 280 530 380 530/730 380 530/730 380 530/730 380 530/730 280 530 380 530/730 380 530/730 9000.
Ein wichtiger Punkt beim Kauf des Geräts Siemens LB54564 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Siemens LB54564 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Siemens LB54564 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Siemens LB54564 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Siemens LB54564 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Siemens LB54564 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Siemens LB54564 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Siemens LB54564. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Siemens LB54564 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.