Benutzeranleitung / Produktwartung CCMX1315-LP des Produzenten Siemens
Zur Seite of 60
Building Technologies Fire Safety & S ecurity Products CCMx1315-LP 1/3” 1.3 Megapixel CCD Col our IP Camera Configuration Manual.
Liefermöglichkeiten und tec hnische Änderungen vorbehalten. Data and design subject to change without not ice. / Supply subject to availability. © 2009 Copyright by Siemens Building Technologies Wir behalten uns alle Rechte an diesem Dokument und an dem in ih m dargestellten Gegenstand vor.
3 Siemens Building Technologies Fire Safety & Security Products 01.2009 Contents 1 Safe ty ....................................................................................................... 6 1.1 Target readers................................
4 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.5 Record ..................................................................................................... 37 7.5.1 FTP recording .......................................
5 Siemens Building Technologies Fire Safety & Security Products 01.2009.
Safety 6 Siemens Building Technologies Fire Safety & Security Products 01.2009 1 Safety 1.1 Target readers The instructions in this document are de signed only for the following target readers: Ta.
Safety 7 Siemens Building Technologies Fire Safety & Security Products 01.2009 Damage due to unsuitable mounting location z The environmental conditions re comme nded by the manufacturer must be observed. See Section 3: Specifications. z Do not operate the device in dusty place s.
EU directives 8 Siemens Building Technologies Fire Safety & Security Products 01.2009 2 EU directives The product complies with the requirements of the following EU directives. The EU declaration of conformity is available from: Siemens Building Technol ogies Fire & Security Products G mbH & Co.
Specifications 9 Siemens Building Technologies Fire Safety & Security Products 01.2009 3 Specifications Image System Description Image sensor 1/3” progressive ExviewHAD CCD, 1.3 Megapixels Effective pixels 1280 (H ) x 960 (V) Image compression method Motion JPEG/ MPEG4 Image frame rate SXGA: 1280 x 960 at 12.
Ordering data 10 Siemens Building Technologies Fire Safety & Security Products 01.2009 4 Ordering data Type Part no. Designation Weight CCMC1315-LP S54561-C80-A1 1/3” 1.3 MP Colour IP Camera 12 V DC / 24 V AC, 50 Hz or PoE 0.55 kg CCMS1315-LP S54561-C80-A2 1/3” 1.
Camera part and connector definition 11 Siemens Building Technologies Fire Safety & Security Products 01.2009 5 Camera part and connector definition 5.
Camera part and connector definition 12 Siemens Building Technologies Fire Safety & Security Products 01.2009 5.2 Connector pin definition 5.2.1 Digital I/O terminal GND AI2 1.
Installing the camera 13 Siemens Building Technologies Fire Safety & Security Products 01.2009 6 Installing the camera 6.1 Precautions SD memory card Please install the SD memory card before switching on the camera as the system cannot detect the insertion of an SD card during operation.
Installing the camera 14 Siemens Building Technologies Fire Safety & Security Products 01.2009 z Temperature increasing o n the surface of the adapter is normal. Before moving the adapter to another location, unplug it from the wall outlet, and wait until its temperature decreases.
Installing the camera 15 Siemens Building Technologies Fire Safety & Security Products 01.2009 6.4 Connecting the camera and pers onal computer via network IP address To connect to the network, the administrat or needs to set the network camera IP address.
Installing the camera 16 Siemens Building Technologies Fire Safety & Security Products 01.2009 Connecting camera and personal co mputer 1. Connect LAN cable and turn the power on. Connect the LAN cable (straight cable) connected to the camera to the hub.
Installing the camera 17 Siemens Building Technologies Fire Safety & Security Products 01.2009 6.5 Using the camera search application "IpFinder" The "IpFinder" is an applicati.
Installing the camera 18 Siemens Building Technologies Fire Safety & Security Products 01.2009 6.6 Using the camera search application "Web cam IP manager" This assumes that: The Web-Cam IP Manager and all the unit s are locat ed in the same network segment.
Installing the camera 19 Siemens Building Technologies Fire Safety & Security Products 01.2009 6.7 Log-in screen 1. Open the Internet Explorer. 2. Enter the default IP address: 192.168.0. 10. You can also use Mozilla Firefox. In that case, you have to download the IE Tab plug-in from the Mozilla Firefox homepage.
Installing the camera 20 Siemens Building Technologies Fire Safety & Security Products 01.2009 4. Click "Level customize". 5. Check the following radio buttons in the displayed list: –.
Installing the camera 21 Siemens Building Technologies Fire Safety & Security Products 01.2009 Camera Image screen When using Windows XP SP2 If the Camera Image screen fails to display, operate as follows. 1. Choose "Pop-up Blocker" on the tool menu.
Configuration 22 Siemens Building Technologies Fire Safety & Security Products 01.2009 7 Configuration 7.1 Compression Image mode z Both functions of JPEG and MPEG4 are effective.
Configuration 23 Siemens Building Technologies Fire Safety & Security Products 01.2009 MPEG4 The following settings are enabl ed when "Compression Mode " is set to "MPEG4". z Resolution: 640 x480 and 320 x240 available. z Bit Rate: 6 modes including 256, 512, 1024, 204 8, 3072 and 4096 kb/s.
Configuration 24 Siemens Building Technologies Fire Safety & Security Products 01.2009 How to operate RTSP NOTE You need to prepare a suitable RTSP player such as Quicktime or VLC media pla yer to receive the data streaming first, then execute the applicati on program.
Configuration 25 Siemens Building Technologies Fire Safety & Security Products 01.2009 z Using Quicktime 1. Select Open URL . 2. Fill in rtsp://<IP address>:<rtsp_port>/livestream 3. Click OK . For example: rtsp://192.168.0.194:554/livestream .
Configuration 26 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.2 Network settings You can set up your camera's basi c se ttings, DDNS, and FTP server by selecting Network Settings in the Configuration menu. 7.2.1 Basic Settings Basic Camera Name Input your camera name here.
Configuration 27 Siemens Building Technologies Fire Safety & Security Products 01.2009 Bandwidth Cont rol OFF: The network camera will stream images at the maximum frame rate allowed by the network. ON: The network camera will stream images up to the set band width; using a lower bandwidth results in lower frame rates.
Configuration 28 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.3 Image parameters 7.3.1 Camera - Basic setting NOTE The Day/Night function is supported by the CCMS1315 network camera only. Day/Night Configure auto black-and-white fu nction.
Configuration 29 Siemens Building Technologies Fire Safety & Security Products 01.2009 Image colour Preset image Four t ypes of specific applic ation conditions such as Indoor, outdoor, tunnel and casino can be selected for a quick and easy setup.
Configuration 30 Siemens Building Technologies Fire Safety & Security Products 01.2009 Fig. 2 Back Light Compensation (The image level of shaded parts i s maintained appropriate) When OFF, rear light correction is not performed. Picture Picture Flip Set image to be upside or down.
Configuration 31 Siemens Building Technologies Fire Safety & Security Products 01.2009 NOTE Max. 8 masks can be set on the screen. The mask function is not supported when the cropping function is on.
Configuration 32 Siemens Building Technologies Fire Safety & Security Products 01.2009 2. Select a type of cropping from VGA, QVGA, 4CIF, 2CIF, CIF, QCIF, and Free Size at the bottom of the screen. Î A red-mesh rectangle will appear on th e screen.
Configuration 33 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.3.4 Camera OSD settings This function sets up the text position and colour of the camera na me, alarm text or DATE/TIME on the screen.
Configuration 34 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.4.1 External digital input 1 z Set an "Alarm Input" ON: Detects an external alarm.
Configuration 35 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.4.3 Motion detection settings These settings are similar to the alarm input setting s, with some additional functions: z Motion detection – Set to ON: open motion detection function.
Configuration 36 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.4.4 Alarm output z Alarm mode: The alarm output can be turned OFF or be activated when any of the following.
Configuration 37 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.5 Record 7.5.1 FTP recording You can save image files via FTP.
Configuration 38 Siemens Building Technologies Fire Safety & Security Products 01.2009 – Recording Frame Set the number of images to be recorded immediatel y after an alarm occurs. Images of the moment when an alarm occurs are not inclu ded. 1, 2, 5, 10, 30 and 60 frames can be se lected if JPEG format select ed.
Configuration 39 Siemens Building Technologies Fire Safety & Security Products 01.2009 z Password (Confirm): Re-enter the password. z FTP Port Number: set “21” as default. z FTP Mode PORT mode: This mode is for most FTP appli cations PASV mode: This mode is used when the camera's network environment is behind a firewall.
Configuration 40 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.5.2 SD recording z Conditions Select whether images are to be store d on the SD card by: Time schedule, alarm input, mo tion alarm or network loss. 1. Configure the individual settings a s described below.
Configuration 41 Siemens Building Technologies Fire Safety & Security Products 01.2009 z Recording by Alarm Configure "Alarm input setting" first. Then select the recording format: – Record source: choose JPEG or MPEG 4 format – Recording frame Set the number of images to be recorded immediatel y after an alarm occurs.
Configuration 42 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.5.3 Emailing recording You can receive images by setting your e-mail account.
Configuration 43 Siemens Building Technologies Fire Safety & Security Products 01.2009 Condition settings for sending e-mail by alarm in Setup E-mail condition to Alarm.
Configuration 44 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.5.4 NAS recording This is a method to store data on a network-based storage d evice. 1. Choose reco rd condition: Select the condition for NAS recordin g: recording by Schedule, Alarm or Motion to trigger the recording session.
Configuration 45 Siemens Building Technologies Fire Safety & Security Products 01.2009 z Scheduled Recording Determine the recording condition: STOP, all day, schedul e 1 or schedule 2 from the recording schedule table for all days from Monday to Sunday.
Configuration 46 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.6 Audio You can set up your audio settings by enablin g audio input and output. Audio input z Audio Input: ON: The external microphone input or int egrated microphone is active OFF: The external microphone input or integrated microphone i s deactivated.
Configuration 47 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.7 Date/Time z Display Check “ON” to displ ay date/time on screen; the position and colour can be set on the camera OSD menu. z Synchronization mode – Manual: Input the date and time to set up system time.
Configuration 48 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.8 Access protection.
Configuration 49 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.8.1 Administrator Administrator Functions Select Administrator in the Configuration menu.
Configuration 50 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.9 Firewall 7.9.1 IP Address Filter Enter the IP addresses which are to be p roces sed by the firewall system into the IP address field. Up to 10 addresses can b e set.
Configuration 51 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.9.3 Forbidden Protocol ICMP or UDP protocol can be rejected by firewall if assigned. 7.10 System 7.10.1 Setting CGI-Lock is a system security setting. It means you can activate or deactivate the login data for the CGI-commands.
Configuration 52 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.10.3 Configuration Camera configuratio n information can be exported and saved to a personal computer. It can also be imported from the personal computer to network cameras.
Configuration 53 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.10.4 Backfocus Click the “Adjust” button, the IRIS of the lens will fully open and a live picture screen will pop up.
Configuration 54 Siemens Building Technologies Fire Safety & Security Products 01.2009 7.11 Log Event Log Select Log in the Configuration menu. You can click the icons on the bottom to see and process the log s, such as: “display all logs”, “display syst em logs”, “display user logs”….
Utility program application 55 Siemens Building Technologies Fire Safety & Security Products 01.2009 8 Utility program application 8.1 NAS player setup Playing back NAS file This application is found on the C D included in the delivery. 1. Execute NAS record setup first.
Utility program application 56 Siemens Building Technologies Fire Safety & Security Products 01.2009 8.3 Firmware update setup This application is found on the C D included in the delivery. You can upd ate multi- network cam eras synchro nously. Perform firmware update in the follo w ing sequence 1.
Maintenance 57 Siemens Building Technologies Fire Safety & Security Products 01.2009 9 Maintenance Defective modules sho uld be sent to the nearest Siemens office to be forwarde d to the service centre.
Keyword index 58 Siemens Building Technologies Fire Safety & Security Products 01.2009 11 Keyword index A Access protection 48 Administrator 49 Advanced user 49 Alarm 9, 33 Audio 9, 46 Audio Event.
Keyword index 59 Siemens Building Technologies Fire Safety & Security Products 01.2009 O Operating humidity 9 Operating temperature 9 Ordering Data 10 OSD settings 33 Overwrite 40 P Package Conten.
Issued by Siemens Building Technologies Fire & Security Products GmbH & Co. oHG D-76181 Karlsruhe www.buildingtechnologi es.siemens.com/ © 2009 Copyright by Siemens Building Technologies Data and design subject to change without notice. Supply subject to availability.
Ein wichtiger Punkt beim Kauf des Geräts Siemens CCMX1315-LP (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Siemens CCMX1315-LP noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Siemens CCMX1315-LP - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Siemens CCMX1315-LP reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Siemens CCMX1315-LP erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Siemens CCMX1315-LP besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Siemens CCMX1315-LP verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Siemens CCMX1315-LP. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Siemens CCMX1315-LP gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.