Benutzeranleitung / Produktwartung EF-3 BAYI des Produzenten Sherwood
Zur Seite of 28
1 ENVIROFIRE PELLET STOVE EF-3 BAYi OWNERS TECHNICAL MANUAL SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD ROAD VICTORIA, BRITISH COLUMBIA V8M-2A3 MODELS FS, FPI and BIH.
ENVIROFIRE INSTALLATION MANUAL TABLE OF CONTENTS INTRODUCTION Important Sa fety Data ........................................................... 3 Pellet Q uality ........................................................................ 4 Warnings and Re commendatio ns.
IMPORTANT SAFETY DATA Please read this entire manual befo re installation and use of this pellet fuel bu rning room heater. Failure to follo w these instructions could result in prop erty damage, bodily injury or even death.
PELLET QUALITY IS IMPORTANT, PLEASE READ THE FOLLOWING PAGE Your pellet stove has been designed to burn wood pellets only. Since there are many manufacturers of wood pellets it is important to select pellets that are free of dirt or any impurities. The Pellet Fuel Industries (P.
WARNINGS AND RECOMMENDATIONS A. Do not abuse the glass by striking or slamming the door shut. B. Do not attempt to operate the stove with broken glass. C. Do not attempt to open the door and clean the glass while the unit is in operation. If you must clean the glass, use a soft cotton cloth and mild window cleaner.
HOW TO START AND OPERATE YOUR PELLET APPLIANCE 1. Check and fill hopper with pellets. 2. Switch on power by pushing the start up switch once only. CONVECTION BLOWER SPEED CONTROL 3. Turn the Dial A Fire knob to the 12 o’clock position. (Lower grade pellets may need a higher setting on the feed rate).
SLIDER/DAMPER INSTALLATION /OPERATION INSTRUCTIONS This is used to regulate the airflow through the pellet stove. INSTALLATION 1. Remove the slider rod (short rod with knob and nuts) and the two nuts from their package and open the left side panel. 2.
AREAS FOR ROUTINE INSPECTION The following should be inspected perio dically to ensure that the a ppliance is operating at it s optimum and giving you excellent heat value: 2-3 DAYS/WEEKLY SEASONALLY .
DOOR GLASS (It is recommended that your dealer replace the glass if broken.) The door glass is made of 5 mm thick, high tempe rature PYROCERAMIC The center panel is 229 mm x 33 0 mm. To replace the glass, unscrew and remove the four glas s retain ers.
ELECTRICAL COMPONENT FUNCTIONS The following is a list of electrical components and their functi ons on the ENVIROFIRE EF-IIIi Bay pellet stove. 1. CONVECTION FAN CONTROL LER This controller is responsib le for varying the speed of the convection blower.
11. 160 ° F (71 ° C) TEMPERATURE SENSOR When this sensor (located on the left side firewall) reache s 160 ° F (71 ° C), the convection blow er will go to high, cooling the unit.
DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE 1. Check clearance s to combustibles. 2. Do not obtain combustion air from an attic, gara ge or any unventilated space. Combustion air may be obtained from a ventilated crawlspace. 3. Do not install the stove in a bedroom.
REMOVING YOUR NEW STOVE FROM IT’S PALLET To remove your new stove from its pallet , open the left and right side panels. There are two wood screws that are holding the bottom of the stove to the pallet. Remove the screws. Close the sid e panels. See PAGE 18 how to install the pedestal.
MASONRY FIREPLACE INSERT INSTALLATION, MODEL FPI The Fireplace Insert model includes surround f ace plates and a pedestal. When installing this unit, ensure that the pedestal is removed from its box and installed on the bottom of the unit. (Surround assembly instructions are in this manual).
ASSEMBLING THE FACE PLATE FOR THE FPI AND BIH MODELS 1. To attach the pedestal, place the unit on its back, making sure not to damage the wiring, then bolt the pedestal onto the unit. Back off the screws on the base, install the pedestal over the screws.
RECOMMENDED FRAMING FOR BUILT IN HEATER When installing model BIH it is recommended that you use the dimensions shown in the diagram below. These type of clearances will make it easy and readily accessible for service. BUILT IN HEATER CLEARANCES TO COMBUSTIBLES This unit includes a 3” (75 mm) pedestal and surrounding faceplates.
FREESTANDING INSTALLATION, MODELS FS CLEARANCES TO COMBUSTIBLES (FREESTANDING) - Side wall to unit A- 6 INCHES (150 mm) - Back wall to unit B- 1 INCH (25 mm) - Corner to unit C- 1 INCH (25 mm) - Mantl.
MODEL FS (FREESTANDING) INSTALLATION PEDESTAL INSTALLATION : Model FS comes with a p edestal that has to be attached prior to installation: - Remove the pedestal from the box - Remove the ENVIROFIRE heater form the box. - Place the unit on its back, making sure not to damage the wiring.
HORIZONTAL EXHAUST THROUGH THE WALL 1. NOTE: Use only listed type “PL” or “L” pellet venting prod ucts . Failure to use listed components may cause damage or personal injury or death.
THROUGH WALL INSTALLATION 1” 20.
FREESTANDING INSIDE VERTICAL INSTALLATION 1. Choose a stove location that is ideal. See the section Deciding Where to Locate Your Pellet Appliance. 2. Place a non-combustible hearth pad where necessary.
FREESTANDING OUTSIDE VERTICAL INSTALLATION To accomplish the above titled installation, follow steps 1 through 8 in the previous section and then finish it by performing the following. 9. Install a tee with clean out on the outside of the house. 10. Install PL vent upward from the tee.
MOBILE HOME INSTALLATION - Secure the heater to the floor using the two bolt holes supplied in the pedestal. - CAUTION: THE STUCTURAL INT EGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED. - Ensure the unit is electrically grounded to the chassis of your home (permanently).
TROUBLESHOOTING DO NOT: - Hold the start-up switch down, this is a momentary contact switch and can be damaged if held down too long. - Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly.
4. The convection blower will not function normally - Check all the connections between the contro ller, switch, and the convection blower against the wiring diagram. - If the convection motor will not run, apply 230V AC to the motor directly. If the m otor runs, replace the fan controller.
placing a jumper across the pins. If the auger now cycles very quickly, test the dial-a-fire potentiometer. If the auger did not cycle then replace the timing control module.
WIRING DIAGRAM 27.
WARRANTY Sherwood Industries Ltd. gives a five y ear limited warr anty on all steel manufa ctured parts. A one year warra nty is provided on all ele ctrical components.
Ein wichtiger Punkt beim Kauf des Geräts Sherwood EF-3 BAYI (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Sherwood EF-3 BAYI noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Sherwood EF-3 BAYI - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Sherwood EF-3 BAYI reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Sherwood EF-3 BAYI erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Sherwood EF-3 BAYI besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Sherwood EF-3 BAYI verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Sherwood EF-3 BAYI. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Sherwood EF-3 BAYI gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.