Benutzeranleitung / Produktwartung GR-131SPF des Produzenten Sears
Zur Seite of 14
SAFETY PRECAUTIONS 1. Check if an electric leakage occurs in the set. 2. When servicing current applying parts, unplug prior to servicing. 3. In case of testing with power injecting, wear rubber gloves to prevent electric shock. 4. If you use any appliances, check regular current, voltage and capacity.
In case that a considerable leakage occurs and to stop the vacuum pump will be necessary and add a small quantity of Freon to the system, if vacuum should not be obtained (pressure gauge can't fall to 1 atmosphere.), start the refrigeration unit and find the leakage with the special leak-finder.
AIR RECHARGING IN COMPRESSOR Test the refrigeration system by connecting it electrically before refilling operation. This is necessary to ascertain the function of the motor-compressor and identify the defects immediately.
In case that a considerable leakage occurs and to stop the vacuum pump will be necessary and add a small quantity of Freon to the system, if vacuum should not be obtained (pressure gauge can't fall to 1 atmosphere.), start the refrigeration unit and find the leakage with the special leak*finder.
SPECIFICATIONS ITEMS SPECIFICATIONS DOOR TYPE 1 DOOR NET CAPACITY 94 l CONDENSER TYPE WALL CONDENSER (FLUSH BACK) DEFROSTING SYSTEM MANUAL TEMPERATURE CONTROL KNOB DIAL ITEMS INSULATION DO_OR _ CABINE.
DISASSEMBLY A. DOOR 1. Loosen 3 screws holding an upper hinge to separate the door body. (Figure 7) Figure 7 B. THERMOSTAT 1. Pull Knob Dial, 2. Loosen 1 screw holding the case and pull it out to remove the Therme cover. (Figure 8) Figure 8 C. COMPRESSOR AND PTC 1.
CIRCUIT DIAGRAM 4 THERMOS'[A'T YL _ BK GN{GN_L) t <_ BK s_ it"__FL _REs_oR P.T.C STARTER YL: YELLOW BK: BLACK BL: BLUE GN:GREEN THE PLUG TYPE ON CIRCUIT DIAGRAM IS SUBJECT TO CHANGE IN DIFFERENT LOCALITIES.
TROUBLESHOOTING DEFECT EFFECT CAUSE REMEDY GROUP PARTIALLY OR COMPLETELY OUT OF REFRIGERANT CHARGE EXCESSIVELY FULL HUMIDITY IN THE SYSTEM PRESENCE OF AIR IN THE SYSTEM BLOCKED CAPILLARY MOTOR- COMPRE.
NO COOLING The Compressor doesn't run, Check if the current flows at the contacting Poor contacting point Replace the Thermostat. Check if the current flows at the contacting point of the starting system. Poor contacting point and broken Replace the device.
COMPRESSOR AND ANOTHER ELECTRIC COMPONENTS Separate the PTC-STARTER from the Compressor and measure the voltage between M and C of the Compressor. Equal to the applied _ r_ voltage. (Rating _ 2> voltage + 10%) I Check the L resistance of the Compressor Motor.
PTC Poor starting or no operating of the Compressor. 4D First, separate the PTC from the Compressor and check the voltage between NO 5 and 6 in the PTC with a muititester or Wheatstone Bridge. F Normal _ Check another electric components. __ Abnormal _ Replace the PTC.
EXPLODED VIEW -14-.
-15-.
HOME DEPOT(HDP) Electrical Specification ITEM GR-051SF GR-131SF GR=151SF BUYER MODEL NAME GR_051SF GR_131SPF GR-151SPF RATED INPUT(W) 70+15% 70+15% 70+15% DEFROST INPUT(W) ENERGY CONSUMPTION(kwh/yr) 288 330 350 AMPERE(Amp) 0.84 1.0 0.7 RATING(V/Hz) 115/60 115/60 115/60 REFRIGERANT R134a R134a R134a CHARGE(Oz) 1.
Ein wichtiger Punkt beim Kauf des Geräts Sears GR-131SPF (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Sears GR-131SPF noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Sears GR-131SPF - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Sears GR-131SPF reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Sears GR-131SPF erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Sears GR-131SPF besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Sears GR-131SPF verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Sears GR-131SPF. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Sears GR-131SPF gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.