Benutzeranleitung / Produktwartung 170AMM11030 des Produzenten Schneider Electric
Zur Seite of 22
31005009 01 170AMM11030 Analog/Digital Momentum I/O Base Use r Guide Version 1.0 31005009 01.
2 31005009 00 November 2 003 Safe ty Info rmation NOTICE Read th ese instr uctions carefully , and loo k at the e quipment to become f amiliar wi th the devic e before t rying t o install , operate, o r maintai n it.
31005009 01 N ovember 20 03 3 170AMM11030 Analog/Digit al Momentum I/O Base Overview This docu ment conta ins th e follow ing t opics : Front Panel Components Overview Thi s section contains an illustra tion of the fro nt panel of th e 170AMM1103 0 I/O base and a des cription of th e LEDs.
4 31005009 01 November 2 003 Component s of the I/O Module: LED Illustratio n The illus tration be low sho ws the LE Ds. LED Descrip tions The follow ing table d escribes th e LEDs.
31005009 01 N ovember 20 03 5 Specifications Overview Thi s sectio n contains s pecificati ons for the 170AMM1103 0 Momen tum I/O base . General Specif ications The follow ing tabl e contains general s pecificat ions for t he I/O base. Each disc rete output is protec ted against sho rt-circuiti ng and overload .
6 31005009 01 November 2 003 Analog Inpu ts The follow ing tab le contains specific ations f or analog inp uts. Number of Chann els 2 Input Rang es ± 10 VDC Inpu t Type Single-ended Resolution 14 bit.
31005009 01 N ovember 20 03 7 Analog Outputs The follow ing tabl e contains specific ations fo r analog o utputs. Discrete Inp uts The follow ing tabl e contai ns speci fications fo r discrete inputs. Number of C hannels 2 Output Ranges ± 10 VDC Resol ution 14 Bit Conversion T imes 1.
8 31005009 01 November 2 003 Discret e Output s The follow ing tab le contains specific ations f or discret e outputs. Description Solid state switch Operating Voltage 16 - 4 2 VDC Absolute Minimum Vo.
31005009 01 N ovember 20 03 9 Physical Dimensions The follow ing tabl e outline s physica l dimension s for the I /O base. Internal Pin Connections Overview This sec tion cont ains an illu stration s howing the internal connecti ons betwee n terminals on the I/O b ase and a n optional busbar.
10 31005009 01 November 2 003 Field Wir ing Guidelines Overv iew This sec tion cont ains wirin g guidelines and prec autions f or wiring the 170AMM11 030 Momentu m I/O ba se. Term inal Connector To connec t field devic es to the I/O bas e, you need a field wiring terminal con nector.
31005009 01 N ovember 20 03 11 Wiring Diagrams Overview Thi s sectio n contai ns diagra ms to as sist you in wiring the follo wing types of devic es. discret e input an d output analog i nput and o utput Discrete I/O Device s The diagra m below s hows field wiring for discrete input and discrete out put devic es.
12 31005009 01 November 2 003 Analog I/O Devices The diagra m below s hows field wiring for a nalog inp ut and ana log output devices. Recom mended fu ses: F3: Us e a 1A fuse , Wickman 1 9181-1A or equivalen t. I/O Ma p I/O Map Modul e Configuration The modu le must b e I/O map ped as 8 contiguo us input w ords an d 8 contig uous output words.
31005009 01 N ovember 20 03 13 Register for Output s Overview 170 AMM11030 analog and d iscrete out put channe ls are confi gured by ente ring the appropriate informati on in outp ut words 1 t hrough 5 a s follows. Note: The module w ill go to fail st ate values if netw ork or commu nication adap ter ATI commu nication is lost.
14 31005009 01 November 2 003 Word 1 System In fo Register This wo rd enables th e module ’s operati on, and spec ifies if user shutdow n value s are expected . Valid se tting for wor d one are 0 001 ... FFFF T h e m o d ul e ’s d e fau l t v al u e a t p o w er- u p f o r th i s reg i st e r is z e ro (module shut d o w n ) .
31005009 01 N ovember 20 03 15 Words 4 ... 5 Analog Fai l State Valu e Register The modul e always expects two words of u ser defin ed data, ev en if the data is n ot used. Th e first wo rd of the user s hutdown fi eld is used for c hannel 1 , the s econd for channel 2 .
16 31005009 01 November 2 003 Range Outpu t Operatin g Range Register for Inputs Overv iew The input regist er is arranged as follows . Output Voltage Data is L eft Justif ied Comment Output Range -10. 000 ... +10. 000 00382 ... 32382 Nominal out put voltage range Output Over Range +10.
31005009 01 N ovember 20 03 17 Word 1 The status word (word 1) contains information a bout the h ealth of th e module an d the status of the di screte out puts, inc luding over temperature or short c ircuit of the discrete outp uts. Word 2 Discret e Input Regi ster This word c ontains a right justifi ed binary 16 bit data f ield.
18 31005009 01 November 2 003 Words 3 ... 4 Analog Input Regis ter Each wor d in this rang e contain s a left j ustified 15 bit data fi eld. The ra nge is fro m 0H to 7FFE hex, but the resolutio n is 14 bit (0 ... 32766 decimal or 0 ... 7FFE hex ). Words 5 .
31005009 01 N ovember 20 03 19 Analog Map Overview 170 AMM11030 analog v alues are mapped as follows. Note: The d isplay i s standar dized, and , in ea ch case, the analog value wil l appear left ju stified. Note: The module re solution is 14-bit (0 .
20 31005009 01 November 2 003 Discr ete I /O Po ints an d IEC Comp liant Data M appin g Overv iew The 170AM M11030 b ase returns 16 discrete input bit s to the pr ocessor i n one 16- bit word (3x). The inpu t points a re field wire d to row 2 of the ba se.
31005009 01 N ovember 20 03 21 Input and Output Ranges Ranges an d Decimal Va lues Input Mea suring Range ± 10 V The volta ge value is calc ulated with the followi ng formul a using th e digital measuran d: Vn = 1600 Va + 16382 (for the li near range).
22 31005009 01 November 2 003 Output Measuring Range ± 10 V The v oltag e valu e is c alcul ated wi th th e foll owing f ormu la usi ng the digit al measuran d: Vn = 160 0 Va + 1638 2 (for the linea r range) . -10.000V 0V 10.238V 10.000V >10.238V linear range Va -10.
Ein wichtiger Punkt beim Kauf des Geräts Schneider Electric 170AMM11030 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Schneider Electric 170AMM11030 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Schneider Electric 170AMM11030 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Schneider Electric 170AMM11030 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Schneider Electric 170AMM11030 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Schneider Electric 170AMM11030 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Schneider Electric 170AMM11030 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Schneider Electric 170AMM11030. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Schneider Electric 170AMM11030 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.