Benutzeranleitung / Produktwartung C2432 des Produzenten Sanyo
Zur Seite of 17
Contents Page IMPORT ANT! Please Read Before Starting .................................. 1 1. GENERAL .......................................................... 2 1-1. T ools Required for Installation (not supplied) 1-2. Accessories Supplied with Indoor Unit 1-3.
1 IMPORT ANT! Please Read Before Starting This air conditioning system meets strict safety and operat- ing standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently .
2 1. General This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning.
3 1-6. Additional Materials Required for Installation 1. Refrigeration (armored) tape 2. Insulated staples or clamps for connecting wire (See local codes) 3. Putty 4. Refrigeration lubricant 5. Clamps or saddles to secure refrigerant tubing 2. Installation Site Selection 2-1.
4 2-2. Outdoor Unit A VOID: ● heat sources, exhaust fans, etc. (Fig. 4a) ● damp, humid or uneven locations. DO: ● choose a place as cool as possible. ● choose a place that is well ventilated. ● allow enough room around the unit for air intake/ exhaust and possible maintenance.
5 Indoor side Outdoor side Set screws f or transportation only Right-rear tubing (recommended) Right tubing Left-rear tubling Fig. 6 Fig. 7a Center of left-rear tubing hole Center of right-rear tubing hole Fig. 7b NOTE Hole should be made at a slight downward slant to the outdoor side.
6 3-3. Install the Rear Panel on the W all Be sure to confirm that the wall is strong enough to sus- pend the unit. See either Item a) or b) below depending on the wall type. a) If Wooden W all (1) Attach the rear panel to the wall with the 10 screws provided.
7 How to replace the grille (1) Close the flaps. (2) Reinstall the grille into the lower part while aligning its tabs on the upper part. (Fig. 15a) Insert the tabs in the slots and push the lower part of the grille back into position. (3) Press at each of the 5 tabs to completely close the grille.
8 3-7. Recommended Wire Length and Diameter Regulations on wiring diameter differ from locality to locality . For field wiring requirements, please refer to your local electrical codes. Carefully observe these regu- lations when carrying out the installation.
9 3-8. Wiring Instructions for Inter-unit Connections (1) Insert the inter-unit wiring (according to local codes) into the through-the-wall PVC pipe. Run the wiring toward the indoor side allowing approx.
10 When connecting each power wire to the corresponding terminal, follow the instructions “ How to connect wiring to the terminal ” and fasten the wire securely tight with the fixing screw of the terminal plate.
11 3-9. Mounting ■ Right-side tubing (1) Shape the refrigerant tubing so that it can easily go into the wall hole. (Fig. 24) (2) Push the wiring, refrigerant tubing, and drain hose through the hole in the wall. Adjust the indoor unit so it is securely seated on the rear panel.
12 3-10. Drain Hose a) The drain hose should be slanted downward to the outdoors. (Fig. 28) b) Never form a trap in the course of the hose. c) If the drain hose will run in the room, insulate the hose with insulation * so that chilled condensation will not damage furniture or floors.
13 4. Refrigerant T ubing 4-1. Indoor Unit T ubing ■ Rear-left tubing For rear-left tubing, optional tube connection (C) (APR- EN46U1B) is necessary . Please consult your nearest sales outlet or A/C workshop. 1. Make a 3-3/16" hole in the wall, centered on the crossing point between the triangle marks (A and B) on the rear panel.
14 4-3. Connecting T ubing between Indoor and Outdoor Units a) T ightly connect the indoor side refrigerant tubing extended from the wall with the outdoor side tubing.
(2) Wrap the armoring tape from the bottom of the out- door unit to the top of the tubing where it enters the wall. As you wrap the tubing, overlap half of each previous tape turn. (Fig. 36) (3) Clamp the tubing bundle to the wall, using 1 clamp approx.
16 5. Remote Control Unit Installation Position The remote control unit can be operated from either a non-fixed position or a wall-mounted position. T o ensure that the air conditioner operates correc.
Ein wichtiger Punkt beim Kauf des Geräts Sanyo C2432 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Sanyo C2432 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Sanyo C2432 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Sanyo C2432 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Sanyo C2432 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Sanyo C2432 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Sanyo C2432 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Sanyo C2432. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Sanyo C2432 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.