Benutzeranleitung / Produktwartung RHFE-750ETRA des Produzenten Rinnai
Zur Seite of 40
— Do not store or use gasoline or ot her flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical swit ch; do not use any phone in your building.
2 Rinnai Corporation RHFE-750ETRA Consumer Safety Information Safety Definitions ........................................ 2 Safety Behaviors and Practices .................. 3 Safety Features .......................................... 3 Specifications .
Rinnai Corporation RHFE-750ET RA 3 Safety Behavior and Practices Safety Features • Overheat: The appli ance will automatically shut down when the appliance ex cee ds a predetermined temperature. • Flame Failure: The appliance will automatically shut down if the burner flame is extinguished.
4 Rinnai Corporation RHFE-750ETRA Application Vented gas fireplace heater; Inbuilt only; for residentia l installation, commer- cial setting, or manufactured home; not des igned for installation in a .
Rinnai Corporation RHFE-750ET RA 5 Features • Direct Vent: Intake air is taken from the outside and the combustion products are exhausted to the outside. Therefore the furnace has no effect on the quality of the indoor air. • Push Button Ignition: Only one push of the STANDBY/ON switch is all that is required to operate the heater.
6 Rinnai Corporation RHFE-750ETRA Operating Instructions Front Panel Description Part Number Flat Metal - Bla ck Front R2 700 Flat Metal - Stainless Steel Front R2701 Radius (curved) Gla ss - Silver F.
Rinnai Corporation RHFE-750ET RA 7 • Use two 1.5V AAA batteries. • To replace batteries unscrew the battery compartment cover located on the back of the remote control counter clockwise. Ensure that the correct polarity is observed. The polarity is engraved into the battery compartment.
8 Rinnai Corporation RHFE-750ETRA Sequence of Operations The combustion fan will ru n for several seconds before ignition to purge the combustio n chamber of any gas. If the front burner fails to ignite the appliance will turn off and fault code 11 will be displayed.
Rinnai Corporation RHFE-750ET RA 9 Adjusting the Temperature Pressing the UP and DOWN buttons will change the temperature setting by 2 degree (F) increments.
10 Rinnai Corporation RHFE-750ETRA Timers Programming the clock and timers The clock must be set before the timers will operate. The temperature setting during timer ope ration is the temperature last used when the appliance was on.
Rinnai Corporation RHFE-750ET RA 11 Care and Maintenance Filters This appliance has two filters which are behind the louvers on either side of t he heater. The louvers are hinged to allow access to the filters. Dirty filters reduce the air flow and the appliance’ s Maintenance Repairs should be perform ed by a qualified service technician.
12 Rinnai Corporation RHFE-750ETRA W ARNING Do not clean glass when hot. Do not clean glass with abrasive clean ers. Care and Maintenance Over time combustion products may leave a film on the combustion chamber g lass. Continued use of the appliance may permanentl y stain the glass.
Rinnai Corporation RHFE-750ET RA 13 T roubleshooting No display on remote Replace the remote control batteries. No ignition or no panel indications Ensure the appliance has power. Press the control panel ON/OFF button. Burners fail to ignite Air may need to be purged from the gas line.
14 Rinnai Corporation RHFE-750ETRA Fault Codes If there is a malfunction the appliance may shut down as a safety precaution and display a fault code to assist in diagnosing the problem. The fault code will flash in the Fault Code Displa y window and the O peration Indicator will flash green.
Rinnai Corporation RHFE-750ET RA 15 Installation Instructions General Instructions A qualified service technici an should install the appliance and inspect it before u se. The installation must conform with lo cal codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.
16 Rinnai Corporation RHFE-750ETRA Flue T erminal Clearances INS I DE CO RN ER D E TA I L FIXED CLOSED OPERABLE FIXED CLOSED OPERABLE B B B A J B M C F B B E D L G A H K I X V AIR SUPPLY INLET VENT TE.
Rinnai Corporation RHFE-750ET RA 17 Ref Description Canadian Installations US Installations A Clearance above grade, verand a, porch, deck, or balcony.
18 Rinnai Corporation RHFE-750ETRA Do not vent the exhaust into ‘natural draft’ flue pipes or a chimney flue. The enclosure must be within these limits: NOTE: These are minimum clearance s. The front panel extends below the surfa ce on which the appliance rests.
Rinnai Corporation RHFE-750ET RA 19 Cor r ec t Flo or Leve l Ins t allat ion Parti cle B oard, MD F , Pl ywood et c. Wa l l Li n i n g Parti cle B oard, MD F , P lyw ood etc . W all Li ning Particle Boar d, MD F , Plywood etc. Wa l l Li n i n g Floor ( T imber , Concre te, Tile, etc.
20 Rinnai Corporation RHFE-750ETRA F l u e M a n i f o l d I n s t a l l a t i o n 1. Disassemble the Flue Manifold The flue consists of 3 parts: • sleeve • inside connection • terminal Disassemble the flue manifold by first pulling out the inside connection.
Rinnai Corporation RHFE-750ET RA 21 2. Assemble and Adjust the Sleeve Lengt h Measure wall thickness through previously drilled 3 1/2 inch (90 mm) hole. The end of the sleeve should prot rude 3/16 - 3/8 inch (5-10 mm) from the outside wall. In the FOT-203 (Vent Kit A) there are 4 parts provided with which to assemble the sleeve.
22 Rinnai Corporation RHFE-750ETRA V e n t i n g 5. Lock the ties Pulling hard on the left and right hand ties, clip the ties over the notches inside the sleev e. You should be able to pull the ties 2 or 3 notches p ast the starting point. Cut the ties, leaving about 3/4 inch (20 mm) past the notch.
Rinnai Corporation RHFE-750ET RA 23 CONDENSATE COLLECTOR, 3CGDS HORIZONTAL TERMINATION, 3CGRHT Maximum Length = 33 feet (10 m) and 3 elbo w s Maximum Length draining back to appliance without a Condensate Collector = 8.2 feet (2.5 m) VERTICAL TERMINATION, 3CGRVT Sloped toward appliance to prevent condensate collectin g in the elbow.
24 Rinnai Corporation RHFE-750ETRA V e n t i n g Vent Length Switch If using extended venting, move the dip switch in the control panel to L-F. Vent Length Switch Additional Venting Clearances Wall Horizontal Vent Termination The distance between the wall and the air inlet cover should be 1.
Rinnai Corporation RHFE-750ET RA 25 6. Unscrew the flue acce ss panel held by two screws located inside the top left hand corne r of the appliance. Slide this panel to the right behind the convection fan. Connections 1. Carefully remove the packaged ceramic logs and place in a safe location.
26 Rinnai Corporation RHFE-750ETRA Connections 9. Remove clamp L and slide the vertical pipe M down into the lower elbow N to remove parts J and K. Separate J and K. 10. Attach pipe J to the flue manifold (or the adapter or the 2 inch elbow for extended venting) with clamp and screw.
Rinnai Corporation RHFE-750ET RA 27 Final Assembly 1. Remove the t wo retaining screws that secu re the combustion chamber glass panel. 2. Rotate an d lift the combustion chamber glass clear of the combustion chamber and place in a safe location. 3. Seat the rear log into the combustion chamber onto its location pins.
28 Rinnai Corporation RHFE-750ETRA Place the condensate tray on top of the lower panel on the left side under the condensate tube. Place it flat so that it matches up with the shape of the lower panel. One edge of the tray has a sho rt lip. Position the tray so that this lip is towards the front of the appliance.
Rinnai Corporation RHFE-750ET RA 29 Air Guide Vanes To move the air flow more to the right or to the left, bend the air guide vanes using o nly light hand pressure. Do not bend repeatedly (no more than 5 times) o r else the vane will break. Install the Front Panel 1.
30 Rinnai Corporation RHFE-750ETRA Operating Instructions FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING If you do not follow these instructio ns exactly, a fire or explosion may result causing property damage, pe rsonal injury or loss of life. A. This appliance is equippe d with an ignition device that automatically lights the pilot.
Rinnai Corporation RHFE-750ET RA 31 Wiring and Schematic Diagrams If any of the original wire as supplied with the appliance must be replace d, it must be replaced with type 18 AWG wire or its equivalent. Label all wires prior to disconnection when servicing controls.
32 Rinnai Corporation RHFE-750ETRA Parts List For replacement parts call Rinn ai at 1-800-621-9419..
Rinnai Corporation RHFE-750ET RA 33 Parts List.
34 Rinnai Corporation RHFE-750ETRA Parts List 121 130 131 120 105 104 119 132 108 106 125 107 114 110 113 112 109 111 98 115 74 117 123 102 118 49 99 126 80 98 100 103 124 122 101 99 133 101 120 115 1.
Rinnai Corporation RHFE-750ET RA 35 Parts List 1 1 10201 PANEL BASE RHFE750ET R 2 2 10777 FOOT KIT RHFE 3 1 BRACKET COMB CHAMBER SUPPORT RH R750 NON SERVICEABLE PART 4 1 BRACKET COMB CHAMBER SUPPORT L.
36 Rinnai Corporation RHFE-750ETRA Parts List 48 2 10359F BURNER ASSEMBLY BRAY 250 Ø3.0 x 2 NG LEFT AND RIGHT ** 48 1 10359B BURNER ASSEMBLY BRAY 250 Ø6.
Rinnai Corporation RHFE-750ET RA 37 Parts List ITEM QTY PART NO. DESCRIPTION COMMENTS 90 1 10271 PACKING FOR AIR INLET BOX 91 1 10278 PACKING COMB FAN RHFE750ETR 92 1 10796 AIR INLET ASSEMBLY RHFE750 .
38 Rinnai Corporation RHFE-750ETRA Consumer Support W arranty Information Limited W arranty RHFE-750ETRA Direct Vent Fireplace What is covered? This Warranty covers any defects in ma terials or workmanshi p, subject to the terms stated below.
Rinnai Corporation RHFE-750ET RA 39 Limited W arranty - continued What will Rinnai do? Rinnai will repair any part or compo nent that is defective in materials or workmanship as set forth as follo ws.
15237 (Issue G) Manufactured by Rinnai New Zealand LTD 105 Pavilion Drive, Airport Oaks Mangerg, Manukau City New Zealand.
Ein wichtiger Punkt beim Kauf des Geräts Rinnai RHFE-750ETRA (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Rinnai RHFE-750ETRA noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Rinnai RHFE-750ETRA - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Rinnai RHFE-750ETRA reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Rinnai RHFE-750ETRA erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Rinnai RHFE-750ETRA besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Rinnai RHFE-750ETRA verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Rinnai RHFE-750ETRA. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Rinnai RHFE-750ETRA gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.