H8S/2655 Series TQFP-120 User System Interface Cable (HS2655ECN61H) for E6000 Emulator User’s Manual HS2655ECN61HE(C).
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document.
i Preface Thank you for purchasing this user system interface cable (HS2655ECN61H) for the Renesas’s original mi crocomputer H8S/2655 series. The HS2655ECN61H is a user system interface cable that c.
ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 4 2.1 Connecting User System Interf ace Cable to Em ulat or Station .
1 Section 1 Configuration CAUTION Use an IC149-120-043-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the TFP-120 package IC socket on the user system. Figure 1 shows the configuration of the HS2655E CN61H user system interface cable for the TFP-120 package.
Figure 1 HS2655ECN61H User System Interface Cable 2.
3 Table 1 lists t he HS2655ECN61H components. Please m ake sure you have all of these com ponents when unpacking. Table 1 HS2655ECN61H Components No. Component Quantity Remarks 1 Cable body 1 Includes.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and w ill damage the user system and the emulator product or will result in PERSONAL INJURY.
Emulator station E6000 Cable body User system interface cable Figure 2 Connecting User System Int erface Cable to Emulator Station 2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part.
6 2.2.2 Soldering IC Socket After fastening, solder the IC socket for a T FP-120 package to the user system. Be sure to completely solder the leads so that the solder slo p s gently over the leads and fo rms solder fillets. (Use slightly more solder than the MCU.
Fasten the user system interface cable head to the IC socket for a TFP-120 package on the user system with t he four screws (M2 x 12 m m; with four flat washers) provi ded. Each screw should be tightened a little at a time, alternating between scre ws on opposing corners.
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8.
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for a TFP-120 package (IC149-120-043-B5: m anufactured by YAMAICHI ELECTRONICS Co., Ltd.
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7.
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head.
MCU Pin 1 IC socket (IC149-120-043-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Screws (M2 x 8 mm) with flat washers Socket cover Figure 8 Installing MCU to User System 13.
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2655 series, turn on the emulator according to the procedures described in the H8S Series E6000 Em ulator User's Manual (HS2000EPI61HE).
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MCU.
6. The JP1 jumper connector is used for t esting. Do not remove t he inserted jumper pin. JP1 Figure 11 JP1 Jumper Connector 16.
Ein wichtiger Punkt beim Kauf des Geräts Renesas TQFP-120 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Renesas TQFP-120 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Renesas TQFP-120 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Renesas TQFP-120 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Renesas TQFP-120 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Renesas TQFP-120 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Renesas TQFP-120 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Renesas TQFP-120. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Renesas TQFP-120 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.