Benutzeranleitung / Produktwartung QFP-144 des Produzenten Renesas
Zur Seite of 21
H8S/2338 Series QFP-144 User System Interface Cable (HS2338ECH61H) for E6000 Emulator User’s Manual HS2338ECH61HE(D).
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document.
i Preface Thank you for purchasing this user system interface cable (HS2338ECH61H) for the Renesas’s original mi crocomputer H8S/2338 series. The HS2338ECH61H is a user system interface cable that c.
ii Contents Section 1 Configuration ................................................................................... 1 Section 2 Connection Procedures .................................................................... 4 2.1 Connecting User System Interf ace Cable to Em ulat or Station .
Section 1 Configuration 1 UTION CA Use an NQPACK144SD socket (manufactured by Tokyo Eletech Coporation) for the FP-144 package IC socket on the user system. Figure 1 shows the configuration of the HS2338E CH61H user system interface cable for the FP-144 package.
To emulator station Cable body Screws (M2 x 6 mm) Socket cover User system IC socket Cable head Screws (M2 x 10 mm) (for fastening cable head) Figure 1 HS2338ECH61H User System Interface Cable 2.
3 Table 1 lists t he HS2338ECH61H components. Please m ake sure you have all of these com ponents when unpacking. Table 1 HS2338ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Includes.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
Emulator station E6000 Cable body User system interface cable Figure 2 Connecting User System Interf ace Cable to Emulator Station 2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part.
2.2.1 Installing IC Socket 1. Confirming t he location of IC socket 6 UTION CA After confirming the location of pin 1 on the IC socket, apply epoxy resin adhesive to the end of the four projections at the bottom of the IC socket, and fasten it to the user system.
2.2.2 Inserting Cable Head 7 UTION CA Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a FP-144 system interface cable head into the IC socket on the user system, as shown in fi gure 4. 2.2.3 Fastening Cable Head CA UTION 1.
Fasten the user system interface cable head to the IC socket for an FP-144 package on the user system with the four screws (M2 x 10 m m) provided. Each screw should be tightened a little at a time, alternating between screws on opposi ng corners.
2.2.4 Connecting Cable Body to Cabl e Head Connect the cable body to the cable head. Cable body Cable head Remove jig Push the remove jig Removing User system Figure 5 Fastening Cable Body 9.
2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for an FP-144 package (NQPACK144SD: m anufactured by Tokyo Eletech Corporation).
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 7. Unit: mm Tolerance: –0.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 8.
Section 3 Installing the MCU to the User System 13 UTION CA 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screws.
MCU Pin 1 IC socket (NQPACK144SD manufactured by Tokyo Eleteck Corporation) User system Screws (M2 x 6 mm) Socket cover Figure 9 Installing MCU to User System 14.
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2338 series, turn on the emulator according to the procedures described in the E6000 Series Em ulator User's Ma nual (HS2000EPI61HE).
16 4. In the H8S/2338 series MCU, the interrupt signal pins can be selected by the register setting. To trace the interrupt signals in the E6000 emulator, se lect the interrupt signa l pins by setting switch P5 on the user system interface cable as shown in table 2.
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensi ons of the recommended m ount pad for the user system IC socket are different from those of the MCU.
Ein wichtiger Punkt beim Kauf des Geräts Renesas QFP-144 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Renesas QFP-144 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Renesas QFP-144 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Renesas QFP-144 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Renesas QFP-144 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Renesas QFP-144 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Renesas QFP-144 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Renesas QFP-144. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Renesas QFP-144 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.