REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 1 of 19 M61323SP/FP Wide Frequency Band Analog Switch REJ03F0201-0201 Rev.2.01 Mar 31, 2008 Description The M61323SP/FP is a semiconductor integrated circuit fo r the RGBHV interface.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 2 of 19 Block Diagram M61323SP V CC (B) G 18 15 16 17 14 13 12 11 10 9 8 6 5 4 3 2 1 7 19 21 20 24 25 26 27 28 29 31 32 30 V CC (R) Input1 (R) V.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 3 of 19 Pin Arrangement V CC 2 (R) Output (R) GND2 (R) V CC 2 (G) Output (B) GND2 (B) G Buffer out Sync SEP in Sync SEP out V CC 3 Input2 (R) In.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 4 of 19 Absolute Maximum Ratings (Ta = 25 ° C) Item Symbol Ratings Unit Supply voltage V CC 7.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 5 of 19 Electrical Characteristics (cont.) SW2 Rin1 SW4 Gin1 SW6 Bin1 SW7 Hin1 SW8 Vin1 SW10 Rin2 SW12 Gin2 SW14 Bin2 SW15 Hin2 SW16 Vin2 SW11 P.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 6 of 19 Electrical Characteristics (cont.) SW2 Rin1 SW4 Gin1 SW6 Bin1 SW7 Hin1 SW8 Vin1 SW10 Rin2 SW12 Gin2 SW14 Bin2 SW15 Hin2 SW16 Vin2 SW11 P.sav Min. Limits Input SW Typ. Max. Unit Test Point (s) SW13 Switch SW22 Sync 18 19 V V ns ns V V 0.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 7 of 19 Electrical Characteristi cs Test Method (M61323SP) Circuit Current 1 No signal. Measure the total circuit cu rrent as I CC when supplying 3 VDC t o pin 11. Circuit Current 2 No signal. Measure the total circuit cu rrent as I CC STBY when pin 11 connected to GND.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 8 of 19 Freq. Characteristic 3, 4 Measure the F C3 , F C4 when SG5 of input signal. (For reference) Crosstalk betw een Tw o Inputs 1, 2 1. The conditions is as tabl e. Th is measurement shall use active probe.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 9 of 19 Pulse Characteristic 1, 2 1. The conditions is as tabl e (SG5 amplit ude 0.7 V P-P ). Set SW13 to GND (or OPEN). 2. Measure rising Tri and fall ing Tfi for 10% to 90% of the input pulse wi th active probe.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 10 of 19 <Sync-Separation> Sync Input Minimum Voltage Gradually decreasing the am plitude of SG7 in pi n 22, measure the am plitude of SG7 when the Sync-Sep output signal turn off. The value is as SYrv.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 11 of 19 Input Signal SG No. Signals SG1 Sine wave (f = 60 kHz, 0.7 V P-P (Amplitude variable) ) 0.7 V P-P (variable) SG2 Sine wave (f = 1 MHz, 0.7 V P-P (Amplitude variable) ) SG3 Sine wave (f = 10 MHz, 0.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 12 of 19 Test Circuit (M61323SP) TP31 0.01 µ 47 µ SW4 75 + ab 47 µ SW7 a b SW8 a b SW15 ab SW16 ab 0.01 µ 47 µ SW10 75 + a b 0.01 µ 47 µ SW12 75 + a b 0.01 µ 47 µ SW14 75 + a b 0.01 µ SW6 75 + TP18 TP28 TP25 TP21 a b + 0.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 13 of 19 Application Example (M61323SP) 0 to 0.8 V : INPUT1 2.0 to 5.0 V: INPUT2 INPUT2 RB GV H PowerSave V CC V CC (5 V) V CC (5 V) V CC (5 V) Power save SW + 0.01 µ 47 µ + 0.01 µ 47 µ + 0.01 µ 47 µ + 0.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 14 of 19 Pin Description (M61323SP) pin No. Name DC Voltage (V) Peripheral Circuit Function 1 3 5 20 V CC (R) V CC (G) V CC (B) V CC (H, V, Sync-Sep.) 5.0 26 29 32 V CC (ROUT) V CC (GOUT) V CC (BOUT) 5.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 15 of 19 Pin Description (M61323SP) (cont.) pin No. Name DC Voltage (V) Peripheral Circuit Function 11 PwrSave-SW 2.5 2.0 V 30 k 15 k 25 k 25 k 10 k 20 k 20 k 20 k Do not apply more 5 V DC voltage 13 CONT-SW 2.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 16 of 19 Pin Description (M61323SP) (cont.) pin No. Name DC Voltage (V) Peripheral Circuit Function 21 Sync sep OUT 15 k 15 k 15 k 100 2.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 17 of 19 Note How to Use This IC (M61323SP) 1. R, G, B input signal is 0.7 V P-P of standard video signal. 2. H, V input is 5.0 V TTL type. 3. Input signal with suffici ent low impedance t o input term inal.
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 18 of 19 Cautions for Manufacturing Boards Built-in wide band p reamplifier may cause oscillation due to the wiring shape on the bo ard. Be careful for the followi ng points. • V CC shall use a stable power supply .
M61323SP/FP REJ03F0201-0201 Rev.2.01 Mar 31, 200 8 Page 19 of 19 Package Dimensions 2. 1. DIMENSIONS "*1" AND "*2" DO NOT INCLUDE MOLD FLASH. NOTE) DIMENSION "*3" DOES NOT INCLUDE TRIM OFFSET. 16 17 32 1 SEATING PLANE *1 *2 *3 *3 E L A A 1 A 2 D e b 3 b 2 b p c 5.
Notes: 1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use. Renesas neither makes warranties or representations.
Ein wichtiger Punkt beim Kauf des Geräts Renesas M61323SP/FP (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Renesas M61323SP/FP noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Renesas M61323SP/FP - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Renesas M61323SP/FP reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Renesas M61323SP/FP erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Renesas M61323SP/FP besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Renesas M61323SP/FP verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Renesas M61323SP/FP. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Renesas M61323SP/FP gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.