FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 WARNING: If the information in these instructions are not followed exactly , a fire or explosion may result causing property damage , personal injury or loss of life.
2 Regency U38 ULTIMATE Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art ULTIMATE Gas Stove by FIREPLACE PRODUCTS INTERNATIONAL LTD. The Regency Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove, at the flick of a switch.
Regency U38 ULTIMATE Freestanding Gas Heater 3 T ABLE OF CONTENTS Page Page Operating Instructions Operating Instructions ................................................. 1 4 Lighting Instr uctions ....................................................
4 Regency U38 ULTIMATE Freestanding Gas Stove This is a copy of the label that accompanies each ULTIMATE Freestanding Gas Stove. We have printed a copy of the contents here for your review. The safety label is located on the inside of the drop down pedestal door.
Regency U38 ULTIMATE Freestanding Gas Heater 5 INST ALLA TION BEFORE YOU ST ART Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety.
6 Regency U38 ULTIMATE Freestanding Gas Stove Side View Rear View Outside Air Through Rear of Pedestal Remove the blanking plate from the rear of the pedestal cover plate and bend the two tabs out 90 degrees. Pipe fresh air into the pedestal area by using duct pipe with a mesh grill at the outside termination.
Regency U38 ULTIMATE Freestanding Gas Heater 7 INST ALLA TION VENTING This heater is a vented appliance and must be connected to a chimney/flue in accordance with the installation codes. Note: The rear pedestal cover plate is only required when outside air is being used.
8 Regency U38 ULTIMATE Freestanding Gas Stove 5) The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label. 6) When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver.
Regency U38 ULTIMATE Freestanding Gas Heater 9 INST ALLA TION Installer Notice: These instructions must be left with the appliance. Burner Orifice CONVERSION FROM NA TUAL GAS T O PROPANE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit 730-969 Contains: Qty.
10 Regency U38 ULTIMATE Freestanding Gas Stove LOG SET INST ALLA TION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced.
Regency U38 ULTIMATE Freestanding Gas Heater 11 INST ALLA TION C)02-44 Pins on Rear Log Support A)02-65 B)02-56 3) Place Rear Log A)02-65 on the two pins on the rear log support. 4) Place the Middle Left Log B)02-56 on the two pins as shown. 5) Sprinkle some lava rock just in front of B) 02-56 on the burner holes.
12 Regency U38 ULTIMATE Freestanding Gas Stove OPTIONAL W ALL THERMOST A T A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams.
Regency U38 ULTIMATE Freestanding Gas Heater 13 WIRING CAUTION: Label all wires prior to discon- nection when servicing con- trols. Wiring er- rors can cause improper and dangerous op- eration.
14 Regency U38 ULTIMATE Freestanding Gas Stove OPERA TING INSTRUCTIONS 3) Wait five minutes to allow gas, that may have accumulated in the main burner com- partment, to escape. If you smell gas, fol- low the instructions on the front of this manual. If you don't smell gas continue on to the next step.
Regency U38 ULTIMATE Freestanding Gas Heater 15 COPY OF THE LIGHTING PLA TE INSTRUCTIONS OPERA TING INSTRUCTIONS 1 ) Push in the gas control knob slightly and turn clockwise to “OFF”. Do not force. FOR YOUR SAFETY READ BEFORE LIGHTING A ) This appliance has a pilot which must be lighted by hand, following the instructions below exactly.
16 Regency U38 ULTIMATE Freestanding Gas Stove NORMAL OPERA TING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly nor- mal due to the fact that there are various gauges and types of steel used within your appliance.
Regency U38 ULTIMATE Freestanding Gas Heater 17 MAINTENANCE 4) Remove the door catch plate. 5) Remove glass retainers on sides first (3 each side) then remove two center retain- ers. Note: Center glass retainers are glued to center glass. 6) Remove glass from extrusions.
18 Regency U38 ULTIMATE Freestanding Gas Stove MAINTENANCE FAN MAINTENANCE If your fan requires maintenance or replace- ment, access to the fan is through the access panel on the rear wall of the firebox. Note: The unit MUST NOT be operated without the fan access panel se- curely in place and correctly sealed.
Regency U38 ULTIMATE Freestanding Gas Heater 19 4) Remove the two outside frame pieces by removing two screws per side. See dia- gram below. REMOVING VAL VE If your valve requires maintenance or replace- ment, follow these instructions: NOTE: Always shut off the gas supply before removing the valve.
20 Regency U38 ULTIMATE Freestanding Gas Stove P ARTS LIST 25) 910-250 Spill Switch 27) 910-233 Thermodisc - Fan Auto/On/Off 28 ) * Mounting Bracket - Fan Thermodisc 30) 750-010 Rear Panel 32) 730-565 Firebox Baffle 33) 560-535 False Top Assembly 34) 590-273 Flue Attachement Bracket 35) 590-930 Ult.
Regency U38 ULTIMATE Freestanding Gas Heater 21 U38 BURNER & LOG ASSEMBL Y 51) 910-241 Burner ON/OFF Switch (3-way) 52) 910-190 P ie zo Ignitor & Nut 53) 904-586 Knob - Fan Control Switch 54) .
22 Regency U38 ULTIMATE Freestanding Gas Stove U38 DOOR ASSEMBLIES PARTS LIST 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door - Complete 730-928 Go ld P.
Regency U38 ULTIMATE Freestanding Gas Heater 23 W ARRANTY Regency Fireplace Products, are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door.
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ __________________________________________________________________ Instal.
Ein wichtiger Punkt beim Kauf des Geräts Regency Wraps U38-NG (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Regency Wraps U38-NG noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Regency Wraps U38-NG - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Regency Wraps U38-NG reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Regency Wraps U38-NG erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Regency Wraps U38-NG besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Regency Wraps U38-NG verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Regency Wraps U38-NG. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Regency Wraps U38-NG gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.