Benutzeranleitung / Produktwartung P33R-NG2 des Produzenten Regency
Zur Seite of 40
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 918-063a MODELS: P33R-NG2 Natural Gas P33R-LP2 Propane P33R Zero Clearance Rear Direct V ent Gas Fireplace 04/26/0.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Stove by FIREPLACE PRODUCTS INTERNATIONAL. The P33R-2 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 3 T ABLE OF CONTENTS Operating Instructions Lighting Plate Instructions ......................................... 2 8 Operating Instructions ............................................
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 4 This is a copy of the label that accompanies each P33R-2 Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the con- tents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 5 INST ALLA TION IMPORT ANT : SA VE THESE INSTRUCTIONS The P33R-NG2 or P33R-LP2 Direct Vent Fire- place must be installed in accordance with these instructions. Carefully read all the instructions in this manual first.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 6 INST ALLA TION CHECKLIST 1) Locate appliance a ) Room location, page 6 b ) Clearances to Combustibles, page 6 c ) Mantle Clearances, page 7 d ) Framing & Finishing Requirements, page 8 e ) Venting Requirements, pages 10 to 15.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 7 COMBUSTIBLE MANTELS INST ALLA TION Clearances for Bay or Flush Front WARNING Fire hazard is an extreme risk if these clearances are not ad- hered to. Because of the extreme heat this fireplace emits, the mantel clearances are critical.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 8 INST ALLA TION Install Side Nailing Strips, and Top Facing Support before unit is slipped into position.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 9 "C" Screw Position: For a facing material depth of 1-1/4"(32mm), the top facing support must be reversed.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 10 EXTERIOR VENT TERMINA TION LOCA TIONS INST ALLA TION . B B B B A C V V V V V V V A A V Fixed Fixed Openable Closed Closed Openable .
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 11 INST ALLA TION VENTING INTRODUCTION The P33R-2 uses the "balanced flue" technology Co Axial system.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 12 INST ALLA TION PROCEDURES for Regency Direct Vent System (Flex) Minimum and Maximum Vent Clearances INST ALLA TION 1) Locate the unit in the framing, rough in the gas (preferably on the right side of the unit) and the electrical (Junction block is on the left side) on the left.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 13 SIMPSON DURA-VENT VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from Regency.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 14 VENTING ARRANGEMENTS - HORIZONT AL TERMINA TIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM or Regency Direct Vent (Flex) for Horizont.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 15 INST ALLA TION • Vent must be supported at offsets • Firestops are required at each floor level and whenever passing through a wall. • Maintain a 1-1/4" clearance to combustibles Note: Must use optional flue adapter when using Simpson Dura-Vent pipe (Part # 510-994).
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 16 VERTICAL TERMINA TION WITH CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 17 Venting Arrangements - Vertical Terminations with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 18 INST ALLA TION Diagram 3 HORIZONT AL INST ALLA TIONS Diagram 1 b) Horizontal runs of vent must be sup- ported every three feet. Wall straps are available for this purpose. 5) Mark the wall for a 10" x 10" square hole.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 19 INST ALLA TION GAS LINE INST ALLA TION The gas line can be brought through either the right or the left side of the appliance. The gas valve is situated on the right hand side of the unit and the gas inlet is on the right hand side of the valve.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 20 P33R-2 System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes: Natural Gas Propane Burner #45 #54 Max. Input Rating - Natural Gas 21,000 Btu/h - Propane 21,000 Btu/h Min.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 21 INST ALLA TION Conversion Kit from Natural Gas to Propane Model #431-969 for P33R-2 using SIT 820 NOV A Gas V alve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Remove the 2 screws, push Burner Assem- bly to the left and lift out.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 22 INST ALLA TION Note: The logs must not be in the unit. 3) Insert the back brick panel by carefully slipping it between the back wall of the firebox and the rear log bracket. OPTIONAL BRICK P ANELS 1) Undo the bottom 2 door latches and open and remove glass door.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 23 Diagram 1 Diagram 3 ST ANDARD FLUSH DOOR The standard flush door comes with a black frame. To install the frame, simply hook the top door flange onto the top of the unit and swing the door towards the unit, diagram 1.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 24 OPTIONAL BA Y DOOR The Bay louvers MUST be used with the Bay glass option. The optional Bay door is an overlay on the flush front. The standard flush door and glass must remain on the unit.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 25 INST ALLA TION OPTIONAL W ALL THERMOST A T A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use table below to determine the maximum wire length.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 26 INST ALLA TION CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 27 INST ALLA TION INST ALLING THE OPTIONAL F AN 120 Volt AC power is needed for the fan switch and blower. The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualified electrician.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 28 OPERA TING INSTRUCTIONS COPY OF THE LIGHTING PLA TE INSTRUCTIONS TO TURN OFF GAS APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if not, follow the current CAN1-B149/ANSI Z 223.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 29 AERA TION ADJUSTMENT The air shutter can be adjusted by moving the adjusting wire up or down. The wire is ac- cessed through the bottom louver opening. Open the air shutter for a blue flame or close for a yellower flame.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 30 MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before clean- ing. For relighting, refer to lighting instruc- tions. Keep the burner and control compart- ment clean by brushing and vacuuming at least once a year.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 31 MAINTENANCE THERMOPILE/ THERMOCOUPLE 1) Open the bottom louvers. 2) Loosen the thermocouple or thermopile with a 7/16" wrench. 3) Disconnect thermocouple by loosening nut from the valve with a 9mm wrench.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 32 gram 2) and then lift the entire assembly out (diagram 3). 10) Undo the pilot tube from the valve with a 7/16" wrench. REMOVING V AL VE 1 ) Shut off the gas supply. 2) Remove the louvers (and bay door if it is on).
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 33 P ARTS LIST Main Assembly Part # Description Part # Description Part # Description 1 ) 948-247 Door Handle 2 ) * Thermodisc Bracket.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 34 Burner & Log Assembly Part # Description 53) 430-055 Gasket - Valve Access Plate - NG/LP 54) 910-421 Pilot ON/OFF Extension Kno.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 35 P ARTS LIST Flush Front & Louvers Part # Description Part # Description 117) 904-196 Magnet - 1' round 130) 430-924 Flush .
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 36 430-930 Bay Front Complete 106) 940-079/P Side Glass 107) 936-243 G lass Gasket 108) 940-078/P Center Glass 110) * Bay Door Frame 1.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 37 _____________________________________________________________________________________ _____________________________________________.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 38 _____________________________________________________________________________________ _____________________________________________.
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 39 W ARRANTY Regency Fireplace Products, are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door.
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ __________________________________________________________________ Instal.
Ein wichtiger Punkt beim Kauf des Geräts Regency P33R-NG2 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Regency P33R-NG2 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Regency P33R-NG2 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Regency P33R-NG2 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Regency P33R-NG2 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Regency P33R-NG2 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Regency P33R-NG2 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Regency P33R-NG2. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Regency P33R-NG2 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.