Kit Contents AA-RS5 Control Module (2) - 2 Button High Frequency Transmitters (1) - 3 Channel Code Learning Receiver (1) - Multi Pin Input/Output Harness (1) - Six Pin Power Harness (1) - Two Pin I/O .
The AA-RS5 Remote Start/Keyless Entry System is designed to be used with Automatic Transmission Vehicles Only! The unit provides wait to start input for glow plug pre-heat which will be used for all diesel applications.
3 IMPORT ANT! DO NOT PLUG THE SIX PIN MAIN POWER HARNESS OR THE MUL TI PIN INPUT / OUTPUT HARNESS INTO THE CONTROL MODULE UNTIL ALL CONNECTIONS TO THE VEHICLE HA VE BEEN MADE. AFTER SELECTING YOUR T ARGET WIRES AS DEFINED BELOW , DISCONNECT THE NEGA TIVE BA TTER Y CABLE FROM THE VE- HICLE BA TTERY PRIOR T O MAKING ANY CONNECTIONS.
SEE NEUTRAL ST ART SAFETY TEST FOR FURTHER DET AILS. BLUE Wire: Ignition 1 Output Connect this wire to the ignition 1 wire from the ignition switch. This wire will show +12 volts when the ignition key.
WIRING CONNECTIONS: 12 Pin Input / Output Harness Black Wire: Chassis Ground Source Connect the Black wire to a known vehicle ground source or to a solid clean metal part of the chassis. Be certain to remove any paint or grease and secure this wire with a self tapping screw and ring terminal.
the Brown w/ Black trace wire to the output of the brake light switch. If the brake light switch in the vehicle switches ground , do not use the Brown w/ Black wire; see Grey w/ Black tracer wire.
LIGHT BLUE Wire: Ignition 3 / Shock Disable Output This wire provides a 300mA ground output that becomes active 3 seconds before the Remote Start Unit initializes, and remains grounded while running plus an additional 4 seconds after the Remote Start Unit turns off.
DARK GREEN Wire: Tach Sensor Input This wire will continually monitor the engine tach rate while the unit is under power of the Remote Start module. This wire will be routed to the vehicle ECM tach input or through the firewall into the engine com- partment and connect to the negative side of the ignition coil.
3 Wire Positive Switched Door Locks: In this application, the Red wire of the two pin harness provides a + 12 volt pulse during the disarming sequence, or pulsed 12 volt unlock output. Connect the Red wire to the low current 12 volt signal wire from the factory door unlock switch to the factory door unlock relay .
10 1. RF Programmable Features: Feature Selection 1 Flash 2 Flash 3 Flash 4 Flash Default 1 Run Time 5 Min. 10 Min. 15 Min. 20 Min. 10 Min. 2 Ign. 2 During Crank Off On On 3 Light Output During Run Steady Flash Steady 4 Tach Mode NA Tach Tach 5 NA NA NA NA NA NA 6 Trouble Shooting Off On Off 7 Door Locks 1 Sec/1 Sec 3.
11 Multi Coil Pack Adaptor: (Optional) The multi coil pack adaptor , (P/N 136B1400), is designed for use with vehicles having multiple ignition coils where a single point tach signal is unavailable. T o use the adaptor , the Green/Black wires must connect to the negative side of the ignition coil(s).
DO NOT RELEASE THIS VEHICLE TO THE CONSUMER UNTIL YOU CONFIRM THE OPERA TION OF THE MANUAL SHUT DOWN / ENABLE FEA TURE. NEUTRAL ST ART SAFETY TEST : The intent of the neutral start switch is to prevent the vehicle from starting while the gear selector is in any position other than Park, or Neutral.
13 3. Connect the Anode, (Non Striped) end, of the diode to one side of the Remote Starts enable switch. 4. Connect the other side of the enable switch to the Black/White enable input wire of the Remote Start unit. The reference diagram below shows a typical GM B Body ECM reference wire and how it is to be connected to the Remote Start Unit.
14 Circuits may be used only if the above circuit is not available. T o connect to the key in sensor as shown in method 1: A. Locate the control wire that connects the drivers door pin switch to the key in sensor switch. B. Cut this wire and connect the ignition cylinder side to chassis ground.
15 NOTE: A second 4002 series diode may be required to maintain the integrity of the hood open, shut down circuit. If this is the case, it must be installed as shown in the diagram above. The anode (Non Striped) side must be connected to the Gray/Black wire of the Remote Start Unit.
WIRING DIAGRAM © 2000 Audiovox Electronics Corp., Hauppauge, NY 1 1788 128-5864A.
Ein wichtiger Punkt beim Kauf des Geräts Audiovox AA-RS5CS (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Audiovox AA-RS5CS noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Audiovox AA-RS5CS - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Audiovox AA-RS5CS reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Audiovox AA-RS5CS erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Audiovox AA-RS5CS besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Audiovox AA-RS5CS verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Audiovox AA-RS5CS. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Audiovox AA-RS5CS gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.