INST ALLA TION & OPERA TING INSTR UCTIONS SWIMMING POOL & SP A HEA TER D-2 Catalog No. 6000.57.1D Effective: 05-21-10 Replaces: 10-26-06 P/N 241243 Rev . 3 W ARNING: If these instructions are not followed exactly , a fire or explosion may result causing property damage, personal injury or death.
2 Rev . 3 reflects the following: Changes to: Parts photos on page 3, dimensional illustration on page 4, Fig. 1 and Fig. 3 on page 5, Illustrated Parts List on page 19.
3 RECEIVING EQUIPMENT On receipt of your equipment, it is suggested that you visually check for external damage to the carton. If the carton is damaged, it is suggested that a note be made on the Bill of Lading when signing for equipment. Remove the complete assembly from the carton.
4 INST ALLA TION REQUIREMENTS Failure to install, maintain and/or operate the Power V ent in accordance with manufacturer ʼ s instructions may result in conditions which can produce bodily injury and property damage.
5 INST ALLA TION 1 . Start off by disconnecting main power to the heater . 2. Remove the front door from the heater . See Fig 1. 3. If this is a retro-fit application, remove existing “Pagoda T op” and discard. See Fig. 2. If equipped with a drafthood, refer to drafthood installation manual for removal process.
6 INST ALLA TION (Continued) 6 . Lower the jacket top back onto the heater and reinstall the (6) Phillips screws. See Fig. 3. 7. If installing on a model 266, 267, 406 or 407 heater , skip step 8. 8. T urn t he Po wer V ent u psi de do wn . Usi ng a 5/ 16” n ut dr iv er , re loc ate t he mo un tin g bra cke ts as s ho wn in F ig.
7 INST ALLA TION (Continued) 1 3. Install the right side outdoor conduit through the top 7/8” hole located on the right side of the heater . See. Fig.
8 INST ALLA TION (Continued) 1 9. Route the 24 V AC harness through the 7/8” grommet, See Fig. 17. 20. Continue to route the harness down through any available grommet hole. See Fig. 18. 21. Wire the harness along with the installed gas valve harness per the wiring diagram.
9 U.S. Ins tallations 1 Canad ian Inst alla tions 2 A Clear ance above gr ade , veranda, p orch , deck, or balco ny 1 ft (30 c m) 1 ft (30 c m) B Clear ance to window or do or that may b e o pened 4 ft (1.
10 VENTING (Continued).
11 VENTING (Continued).
12 VENTING (Continued).
13 VENTING (Continued).
14 SEQUENCE OF OPERA TION On call for heat, the PC board will go through its safety chain (water pressure switch, high limit 1 & 2, roll-out, etc.). When the safety chain is closed, the IID pilot will begin to spark and the pilot gas valve will open.
15 WIRING (Continued) STEP 1 : VERIFY CURRENT CONNECTIONS AS SHOWN BELOW . P/PV C/ M/MV MV PV R/BK Y/BK Y/BK V/BK V/BK V/BK Y/BK G/BK P4 1 RELA Y D-2 POWER VENT Y/BK HONEYWELL V AL VE Y/BK V/W V/BK HONEYWELL V AL VE PV MV M /MV C/ P/PV STEP 2 : DISCONNECT BOTH TERMINALS MVPV & MV AS SHOWN BELOW .
16 WIRING (Continued) MODELS 206, 266, 336, 406 EQUIPPED WITH HONEYWELL GAS V A LV E V/W V/BK V/BK G/BK R/BK 1 P4 D -2 POWER VENT P/PV C/ M/MV MV PV HONEYWELL V AL VE STEP 4 : CONNECT THE MAIN V AL VE LINE, FEMALE SP ADE TO MALE SP ADE AS SHOWN BELOW .
17 WIRING DIAGRAM – MODELS 207A, 267A, 337A, 407A POWER VENT D-2 D-2 BLOWER POWER VENT GAS V AL VE HONEYWELL 1 1 + -.
18 WIRING DIAGRAM – MODELS 206A, 266A, 336A, 406A POWER VENT D-2 D-2 BLOWER POWER VENT + - 1 1 TH TR.
19 REPLACEMENT P ARTS NOTE: T o supply you with the correct part, it is impor- tant that you supply the heater model number , serial number and type of gas when applicable.
20 w w w .r ay pak .co m Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468 Litho in U.S.A..
Ein wichtiger Punkt beim Kauf des Geräts Raypak D-2 POWER VENT 206A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Raypak D-2 POWER VENT 206A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Raypak D-2 POWER VENT 206A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Raypak D-2 POWER VENT 206A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Raypak D-2 POWER VENT 206A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Raypak D-2 POWER VENT 206A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Raypak D-2 POWER VENT 206A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Raypak D-2 POWER VENT 206A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Raypak D-2 POWER VENT 206A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.