Raypak Commer cial Swimming P ool Heaters P art 1: Safety warning P art 2: Models 538 to 4224 P art 3: W arranty.
3 CONTENTS P art 1: For Y our Safety This Installation and Operating Instructions Manual is provided with the necessary information for the proper installation, operation and maintenance of your Raypak Heater . Please review and follow these procedures carefully .
P ART 1 - FOR Y OUR S AFETY 4 K eep this manual in a saf e and accessible place f or easy ref er ence in the futur e. This Installation and Operating Instr uctions Manual is pr ovided with the necessary infor mation f or the proper installation, operation and maintenance of y our Raypak Heat er .
P ART 1 - FOR Y OUR SAFETY 5 Ceramic Firetile Refractory is used in Raypak Heaters Possible risks of irreversible ef fects Harmful by inhalation May be irritating to the skin, eyes and respiratory system. WHEN HANDLING • Minimise airborne dust. • Wear an appr oved mask or respirator .
6 Raypak Commer cial Swimming P ool Heaters P art 2: Models 538 to 4224.
7 P ART 2 - SECTION I - INS T ALLA TION INSTRU CTIONS Before commencing installation: 1. Read these instructions in full ! 2. Check that the heater you have been supplied is suitable for the type of installation and the gas available. The gas supply pressure must be between the minimum and maximum shown on the heater data plate.
P ART 2 - SECTION I - INS T ALLA TION INSTRU CTIONS 8 Raypak recommends a minimum length of vertical flue of three (3) metres to ensure correct draft. OUTDOOR INST ALLA TIONS. An outdoor heater must not be installed inside any roofed structure or under eaves, roof overhangs, or pool decks.
9 P ART 2 - SECTION I - INST ALLA TION INSTRU CTIONS PUMP SELECTION The filtration pump must be sized to provide an adequate water flow for the filtration system and the heater .
C OMMISSIONING W ARNING: COMMISSIONING MUST ONL Y BE UNDERT AKEN BY A PROPERL Y AUTHORISED AND IN SOME CASES APPROPRIA TEL Y LICENSED PERSON WHO IS F AMILIAR WITH SAFE COMMISSIONING PROCEDURES. THE COMMISSIONING MA Y REQUIRE INSPECTION BY THE GAS SUPPL Y AUTHORITY , CHECK IF THIS IS APPLICABLE.
TO TURN OFF THE HEA TER 1. T urn the heater ON/OFF power isolation switch to the "OFF" position. EMERGENC Y SHUT -DOWN 1. T urn "OFF" the power supply to the heater 2. T urn "OFF" the gas isolation valve fitted close to the heater or the main gas supply .
P ART 2 - SECTION II - OPERA TING INSTRU CTIONS LO CA TION OF CONTROLS 1. FLAME FAILURE RESET: This is a combination rest button and indicator lamp. It indicates, when illuminated, that the ignition system has shutdown on its safety control.
13 P ART 2 - SECTION II - OPERA TING INSTRU CTIONS LO CA TION OF CONTROLS RL1 MTR12 INSTRU CTIONS FOR USE OF LAE ELECTRONIC THERMOST A TS. Raypak uses the MTR12T1RES series thermostats which is programmed to operate in the heating mode.
14 P ART 2 - SECTION II - OPERA TING INSTRU CTIONS MODELS WHICH ARE C ONNECTED T O A MICROZONE SYS TEM If the heater(s) are operated by a Microzone system, there will be a rotar y type control knob fitted which should be aligned to the desired temperature.
15 P ART2 - SECTION II - OPERA TING INSTRU CTIONS RECOMMENDED SERVICE PROCEDURES It is a Raypak requirement that all Raypak supplied equipment is serviced at least annually . In some installations, due to the appliance location and/or workload it may be necessary to perform a service ever y six months.
16 W ARNING!.
17 P ART 4 - W ARRANTY RA YP AK WARRANTY FOR COMMERCIAL SWIMMING POOL HEA TERS. Raypak Australia Pty Ltd* will: a) repair or , if necessary , replace any Raypak pool heater; or b) replace any componen.
18 NO TES.
RHEEM SERVICE 1 31 031 WWW .RHEEM.COM.A U Quality System Quality Endorsed Company Manufactured by Raypak A ustralia 7 Geddes St. Mulgrav e Vic 31 70 Ph.
Ein wichtiger Punkt beim Kauf des Geräts Raypak 538 To 4224 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Raypak 538 To 4224 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Raypak 538 To 4224 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Raypak 538 To 4224 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Raypak 538 To 4224 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Raypak 538 To 4224 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Raypak 538 To 4224 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Raypak 538 To 4224. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Raypak 538 To 4224 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.