Benutzeranleitung / Produktwartung SCS232 des Produzenten Raritan
Zur Seite of 39
Rackit ® Technology Corporation 2 7 4 Madison Avenue , New York, NY 1 001 6 T el: (212) 679-0050 • Fax: (212 ) 679-0040 1.800.636.3434 www.RackitT echnology.
This page intentionally left blank.
Copyright © 2002 Raritan Computer, In c. SCS232-0C July 2002 Raritan Computer Inc. 400 Cottontail Lane Somerset, NJ 08873 USA Tel. 1-732-764-8886 Fax. 1-732-764-8887 E-mail: sales@raritan.com http://www.raritan.com Raritan Computer Europe, B.V. Eglantierbaan 16 2908 LV Capelle aan den IJssel The Netherlands Tel.
This page intentionally left blank.
FCC I NFORMATION This equipment has been tested and found to comply wi th the limits for a Class A digi tal device, pursuant to Part 15 of the FCC Rules. These limits are design ed to provide reasonable protection against harmful interference in a commercial installation .
This page intentionally left blank.
T ABLE OF C ONTENTS C HAPTER 1: M ANUAL N OTES ........................................................................................ 1 V ERSION A PPLICABILITY .........................................................................................
.
C HAPTER 1: M ANUAL N OTES 1 C HAPTER 1: M ANUAL N OTES V ERSION A PPLICABILITY Contents in this manual are applicable to Con sol eSwitch™ SCS232 firmware versions 0A2 and above. Customers with 0A1 firmware s hould contact Raritan Techni cal Support for upgrade instructions.
2 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL.
C HAPTER 2: I NTRODUCTI ON 3 C HAPTER 2: I NTRODUCTION C ONSOLE S WITCH SCS232 F EATURES • Dual user, simu ltaneous matrixed access to 32 serial devices • Compact 1U form factor • 8kb data buffers for troubleshooting • Seamless integration wi th Raritan’s Paragon ® data center mana gement solution.
4 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL P RODUCT P HOTOS Figure 1 . ConsoleSwitch SCS232 Front Figure 2. ConsoleSw itch SCS232 Ba ck R ELATED P RODUCTS D EVICE A DAPTERS Each serial device connected to ConsoleSwitch will require an RJ45 to DB9, o r RJ45 to DB25, adapter.
C HAPTER 3: I NTRODUCTION R EQUIREMENTS 5 C HAPTER 3: C ABLING R EQUIREMENTS C ONSOLE S WITCH C ABLING : S ERIAL O VER UTP N OTE : The following information applies only to cabl es that attach directly to the ConsoleSwitch unit.
6 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL P ARAGON C ABLING : KVM O VER UTP N OTE : The following information addresses th e stricter cabl in g requirements of Raritan’s Paragon switches. These specifications are mor e st ringent than for ConsoleSwitch.
C HAPTER 4: I NSTALLATION 7 C HAPTER 4: I NSTALLATION C ONSOLE S WITCH S TANDALONE I NSTALLATION N OTE : The following information applies to configur ations in which ConsoleSwitch is used as a standalone serial access device.
8 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL C ONNECTING U SER C ONSOLES 1. In your ConsoleSwitch shipment (see Chapter 2: Introduction - Pa ckage Cont ents), you will find an assortment of nulling serial ad apters (RJ45 to DB9 / DB-25). 2. Locate the RS232 (serial) port on ea ch devi ce that you wish to use as a user console.
C HAPTER 4: I NSTALLATION 9 P OWER O N 1. With your user consoles and devices attached, conne ct the supplied AC power co rd to ConsoleSwitch , and switch the power on. Note th at terminals and devi ces may b e attached or disconnect ed at any time. 2.
10 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL This section only applies if you wish to operate Consol eSwitch with a user console (dumb term inal or terminal emulator) set to communicatio ns settings other than 9600 Baud, No Parity, 8 Data Bits, 1 Stop Bit.
C HAPTER 4: I NSTALLATION 11 P REPARE D EVICES Devices to be controlled by Paragon through ConsoleSwitc h must be set at the following communications settings. Before proceeding, check all devices that you wish to connec t , and ensure that they hav e been set correctly.
12 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL C ONNECTING C ONSOLE S WITCH TO P ARAGON All cabling performed in the fo llowing steps must confor m to the requirements specified in Chapter 3: Cabling Requirements -Paragon Cab ling – KVM over UTP. 1.
C HAPTER 4: I NSTALLATION 13 2. When the update is complete, l ogin as “ admin ” (default password is “ raritan ”). Channel numbers corresponding to Paragon device por ts connected to ConsoleSwitch SC S232 should appear in burgundy (each is a “path” to the SCS232).
14 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL.
C HAPTER 5: O PERATING C ONSOLE S WITCH 15 C HAPTER 5: O PERATING C ONSOLE S WITCH P ARAGON O PERATION : V IEWING S TORED D ATA When using ConsoleSwitch in tandem with Raritan’s Paragon server ma nagement solution, users access and operate serial devices conne cted to ConsoleSwitch via Paragon’s me nus and functions.
16 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL A CCESSING THE M AIN M ENU • At any time while in Hot Key mode, you may invoke the main men u by pressing H ↵ . • When interacting di rectly with a connected device, press the < ESC > key twice to enter HotKey mode, and the main menu will appear.
C HAPTER 5: O PERATING C ONSOLE S WITCH 17 S ELECTING A C HANNEL By Channel Number. To s elect a channel by number from the m ain menu, simply enter the keys trokes C# ↵ , where # is a number between 1 and 32, indicating the Consol eSwitch port to which the desired serial device is connected.
18 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL D — Display Scan List To see a list of all channels on your scan list, press D ↵ . This screen is identical to th e channel selection and display screen referenced earlier in this manual (Figure 10).
C HAPTER 5: O PERATING C ONSOLE S WITCH 19 F# — Forward # Lines Moves the display cursor a user-det ermined number of lines forward to a new screen starting point, # number of lines forward. R# — Reverse # Lines Moves the display cursor a user-determined numbe r of lines backward to a new screen sta rting point, # number of lines backward.
20 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL.
A PPENDICES 21 A PPENDICES A PPENDIX A: S PECIFICATIONS D IMENSIONS 17.3” (W) X 6.4” (D) X 1.75” (H) 439 MM (W) X 163 MM (D) X 44 MM (H) 1U F ORM F ACTOR W EIGHT 5.
22 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL A PPENDIX B: P IN -O UT D IAGRAMS In order to provide maximum port density and to enab le simple UTP (Category 5) cabling, ConsoleSwitch provides its 32 serial connections vi a co mpact RJ45 ports. However, no wide ly adopted industry -standard exists for sending serial data over RJ45 connections.
A PPENDICES 23 SCSDB9F N ULLING S ERIAL A DAPTER P IN -O UT RJ45 (Female) DB9 (Female) 1 8 2 1, 6 3 2 4 SHELL 5 5 6 3 7 4 8 7 SCSDB9M N ULLING S ERIAL A DAPTER P IN -O UT RJ45 (Female) DB9 (Male) 1 8 .
24 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL A PPENDIX C: U PDATING P ARAGON F IRMWARE N OTE : This Appendix does not apply to users deployi ng Co nsoleSwitch as a standalone serial switching device. This Appendix applie s only to users deploying ConsoleSwitch with Raritan’s Paragon™ data ce nter management solution.
A PPENDICES 25 P ARAGON F IRMWARE U PDATE I NSTRUCTIONS 1. Download the Paragon Firmware distribution file (ParagonFirmware.zip), available at the Raritan web site: http://www.raritan.com . 2. Unzip the downloaded file, and read the rele ase notes for any ad ditional or update d instructions.
26 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL 5. Click the “Test Hex File” butto n to ensure file integrity. 6. Click “Check Device Information” to confirm successful communication with the Paragon Matrix Switch, as well as to confi rm that the firmware upgrade is applicable.
A PPENDICES 27 A PPENDIX D: U PDATING C ONSOLE S WITCH SCS232 F IRMWARE I NTRODUCTION To take advantage of the l atest feat ures an d ensure the best performanc e of your Consol eSwitch SCS232 unit, y.
28 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL 10. ConsoleSwitch SCS232 will clear the screen an d display the following: Transmit the update file using the XMODEM protocol now. N OTE : Steps 9 & 10 describe the XMODEM file transfe r procedures using the standard Wi ndows terminal application, HyperTerminal.
A PPENDIX E: P ARAGON WITH C ONSOLE S WITCH FAQ 29 A PPENDIX E: P ARAGON WITH C ONSOLE S WITCH FAQ This section addresses questions specific to operat ional issues when using ConsoleSwitch SCS232 with Raritan’s Paragon KVM system.
30 C ONSOLE S WITCH SCS232 U SER ’ S M ANUAL A PPENDIX F: C ONSOLE S WITCH FAQ Q: My device has a serial console port jack that is RJ45. Can I use a normal Cat5 network cable to connect it to ConsoleSwitch’s device ports? A : No.
255-60-0010.
Ein wichtiger Punkt beim Kauf des Geräts Raritan SCS232 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Raritan SCS232 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Raritan SCS232 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Raritan SCS232 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Raritan SCS232 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Raritan SCS232 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Raritan SCS232 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Raritan SCS232. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Raritan SCS232 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.