Benutzeranleitung / Produktwartung RCI-6300F TB des Produzenten Ranger
Zur Seite of 45
Ranger Communications Inc. RCI-6300F HP RCI-6300F TB 10 Meter Amateur Radio Ranger Service Manual.
- 1 - RCI-6300F HP RCI-6300F TB TABLE OF CONTENTS PAGE CHAPTER 1 SPECIFICATIONS 1.0 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.1 Transmitter . . . . . . . . . . . . . . . . . . . . . .
- 2 - RCI-6300F HP RCI-6300F TB CHAPTER 1 SPECIFICATIONS 1.0 GENERAL Model RCI-6300F HP / RCI-6300F TB Frequency Range 28.245 - 29.655MHz. Emission Modes AM/FM (A3/F3) Frequency Control Phase Lock Loop (PLL) synthesizer. Frequency Tolerance ± 0.005 %.
- 3 - RCI-6300F TB OPERATION Figure 2-1 Front Panel 2.0 INTRODUCTION This section explains the basic operating procedures for the RANGER RCI-6300F HP / RCI-6300F TB mobile transceiver. 2.1 CONTROL AND CONNECTIONS 2.1.1 FRONT PANEL Refer to the above Figure 2-1 for the location of the following controls.
- 4 - Adjusts the microphone gain in the transmit and PA modes. This controls the gain to the extent that full talk power is available several inches away from the microphone. In the Public Address (PA) mode, the control functions as the volume control.
- 5 - 17. S-RF/SWR SWITCH This is a two-function switch. In the S-RF position, the meter will indicate the strength of the signal being received, as well as the relative RF output of transmission. To use the meter to measure the standing wave ratio, turn the switch to the SWR position.
- 6 - Figure 2-2 Rear Panel 1. ANTENNA This jack accepts 50 ohms coaxial cable with a PL- 259 type plug. 2. POWER This connector accepts 13.8V DC power cable with built-in fuse. The power cord provided with the radio has a black and red wire. The black goes to negative and the red goes to positive.
- 7 - 1 28.245 28.695 29.145 28.315 28.765 29.215 2 28.255 28.705 29.155 28.325 28.775 29.225 3 28.265 28.715 29.165 28.335 28.785 29.235 4 28.285 28.735 29.185 28.355 28.805 29.255 5 28.295 28.745 29.195 28.365 28.815 29.265 6 28.305 28.755 29.205 28.
- 8 - 2.3 OPERATION 2.3.1 PROCEDURE TO RECEIVE 1. Be sure that power source, microphone and antenna are connected to the proper connectors before going to the next step. 2. Turn unit on by turning VOL knob clockwise on transceiver. 3. Set the VOL to a comfortable listening level.
- 9 - 4 WIRE MIC CABLE Pin Number Mic Cable Lead 1 Audio Shield 2 Audio Lead 3 Transmit Control 4 Receive Control Figure 2-3 Your Transceiver Microphone Schematic Figure 2-4 Microphone plug pin numbers viewed from rear of pin receptacle. RCI-6300F HP RCI-6300F TB CHAPTER 3 CIRCUIT DESCRIPTION 3.
- 10 - 3.1 PLL CIRCUIT The Phase Lock Loop (PLL) circuit is responsible for developing the receiver’s first local oscillator signal and the transmitter’s exciter signal. The PLL circuit consists primarily of IC2, IC3, IC4, IC5 Q25, Q27, Q28, Q29 and Q61.
- 11 -.
- 12 -.
- 13 - RCI-6300F HP / RCI-6300F TB FREQUENCY COUNTER CIRCUIT DIAGRAM.
- 14 - RCI-6300F HP / RCI-6300F TB ECHO BOARD (EB-99) CIRCUIT DIAGRAM.
- 15 - RCI-6300F HP RCI-6300F TB CHAPTER 4 ALIGNMENT 4.0 REQUIRED TEST EQUIPMENT ! DC Power Supply (13.8VDC, 20A) " RF Wattmeter (25~60 MHz, 100W) # Multimeter (Digital) $ Automatic Modulation Me.
- 16 - ITEM U.U.T. SETTING ADJUST POINT MEASUREMENT TX Power Set radio to Fr Pool 2, CH 19 AM TX mode. Connect “short PCB” to TP7, TP8 and TP9. Connect RF Power Meter to antenna jack. Set RF Power Fully Clockwise. L40,L42,L43, L44 L40,L42 Power MAX.
- 17 - POINT AM Sensitivity Set radio to Fr Pool 2, CH 19 AM RX mode. Set RF Gain Fully Clockwise. Set SQ Fully Counter Clockwise. Set VOL Control at 2 o’clock. Set NB-ANL/OFF switch to OFF position. Connect RF SG to antenna jack Frequency 28.915 MHz, 1uV.
- 18 - Figure 4-2 Receiver test setup.
- 19 - Figure 4-3 Main PCB Adjustment Location.
- 20 - RCI-6300F HP RCI-6300F TB CHAPTER 5 MAINTENANCE 5.0 PRECAUTIONS The inherent quality of the solid-state components used in this transceiver will provide many years of continuous use. Taking the following precautions will prevent damage to the transceiver.
- 21 - RCI-6300F TB PARTS LIST 6.0 GENERAL Information on most electrical and mechanical parts is included in the parts list. The reference designators are in alphanumeric order. 6.1 ORDERING REPLACEMENT PARTS Parts orders should be referred to the Parts Department at: • Ranger Communications, Inc.
- 22 - PART LIST: RCI-6300F HP / RCI-6300F TB ROTARY SW P.C.B ITEM REFERENCE NUMBER RANGER PART NUMBER DESCRIPTION 1 EPT690020Z ROTARY SW P.C.B 2 R300-R310,D325, D331,D336 RCY010004Z 0 OHM 0.1W 3 R312-R325 RCY011024Z 1K OHM 0.1W 4 R327 RCY012224Z 2.2K OHM 0.
- 23 - PART LIST: RCI-6300F HP ANT P.C.B ITEM REFERENCE NUMBER RANGER PART NUMBER DESCRIPTION 1 EPT360042Z ANT P.C.B 2 R9 RCY010004Z 0 OHM 0.1W 3 R1 RCY014714Z 470 OHM 0.1W 4 R3,R4 RCY011014Z 100 OHM 0.1W 5 R2 RCY013314Z 330 OHM 0.1W 6 R5,R11 RCY011024Z 1K OHM 0.
- 24 - PART LIST: RCI-6300F TB POWER P.C.B ITEM REFERENCE NUMBER RANGER PART NUMBER DESCRIPTION 1 EPA010010A POWER P.C.B 2 R904 RCU141094Z 1 OHM 1/4W 3 R905,R906 RCU141004Z 10 OHM 1/4W 4 R909 RCP14103.
- 25 - NUMBER 11 COPPER SIDE RCY011014Z 100 OHM 0.1W 12 C901 CC0501015A 100PF 50WV 13 C943 CC0500591A 0.5PF 50WV 14 C906,C926,C932, C937,TERMINALx2 CC0501037L 0.01uF 50WV 15 C905,C920,C921,C923x2, C924x2,C925,C935,C939, C941,T901-902x2, C927-C931,C933,C940 CC0501047L 0.
- 26 - PART LIST: RCI-6300F HP / RCI-6300F TB BAND SWITCH P.C.B ITEM REFERENCE NUMBER RANGER PART NUMBER DESCRIPTION 1 EPT630030Z BAND SWITCH P.C.B 2 R1 RCP164704Z 47 OHM 1/16W 3 R2,R3 RCP161024Z 1K O.
- 27 - PART LIST: RCI-6300F HP / RCI-6300F TB MIC P.C.B ITEM REFERENCE NUMBER RANGER PART NUMBER DESCRIPTION REMARK 1 EPT690050Z MIC P.C.B 2 C502-C504 CC0501027L 0.001uF 50WV 3 C501 CC0501027L 0.001uF 50WV RCI-6300F HP 4 C505,C506 CC0501037L 0.01uF 50WV 5 L501 ECCHK16001 CHOKE COIL 5.
- 28 -.
- 29 - PART LIST: RCI-6300F HP / RCI-6300F TB COUNTER P.C.B ITEM REFERENCE NUMBER RANGER PART NUMBER DESCRIPTION 1 EPT900040Z COUNTER P.C.B 2 R40 RCY010004Z 0 OHM 0.1W 3 R19-R39 RCY011014Z 100 OHM 0.1W 4 R6 RCY013314Z 330 OHM 0.1W 5 R9 RCY014714Z 470 OHM 0.
- 30 - PART LIST: RCI-6300F HP / RCI-6300F TB LED DISPLAY P.C.B ITEM REFERENCE NUMBER RANGER PART NUMBER DESCRIPTION 1 EPT900022Z LED DISPLAY P.C.B 2 DISPLAY PCB EX03N40003 LED DISPLAY 3 1,2,3,4,5,6 EX03N40476 LED DISPLAY 4 TX/RX EX01N40004 LED 5 ON,NB/ANL,R.
- 31 -.
- 32 - PART LIST: RCI-6300F HP / RCI-6300F TB ECHO P.C.B (EB-99) ITEM REFERENCE NUMBER RANGER PART NUMBER DESCRIPTION 1 EPT0SSB50F ECHO P.C.B 2 R3,R16 RCY011014Z 10 OHM 0.1W 3 R28 RCY014714Z 470 OHM 0.1W 4 R27 RCY011024Z 1K OHM 0.1W 5 R7 RCY012224Z 2.
- 33 - RCI-6300F HP / RCI-6300F TB MAIN PCB. REMARK: COPPER SIDE (WHITE).
- 34 - PART LIST RCI-6300F HP MAIN PCB REFERENCE NUMBER RANGER PART NO. DESCRIPTION EPT690010Z MAIN P.C.B R246 RCP164794Z 4.7 Ω 1/16W R267 RCP161504Z 15 Ω 1/16W R241,242 RCP162204Z 22 Ω 1/16W R133,.
- 35 - 158,275,276 C80,181 CE0252267Z 22UF 25WV C37,175 CE0254767Z 47UF 25WV C107,156,238,293 CE0161077Z 100UF 16WV C152,179 CE0163377Z 330UF 16WV C91 CE0104777Z 470UF 10WV C243,248 CE0251087Z 1000UF 25WV C35 CEM254767Z 47UF 25WV FL1 EFCFW455HT C/FILTER 455HT FL2 EFCFE107MX C/FILTER 10.
- 36 - RCI-6300F HP MISC. PARTS REFERENCE NUMBER RANGER PART NO. DESCRIPTION - MM7878041B HEAT SINK - MT3001021X SET CHASSIS - MT3600050X DC SOCKET HOLDER 2SB754Y XZZZ90020Z INSULATING PLATE Q47,48,49.
- 37 - PART LIST RCI-6300F TB MAIN PCB REFERENCE NUMBER RANGER PART NO. DESCRIPTION EPT690010Z MAIN P.C.B R246 RCP164794Z 4.7 Ω 1/16W R267 RCP161504Z 15 Ω 1/16W R241,VR10 RCP162204Z 22 Ω 1/16W J3(2.
- 38 - 50WV C78 CM0502245Z .22UF 50WV C10 CE0504747Z 0.47UF 50WV C67,75,153,157,170, 186,187,198 CE0501057Z 1UF 50WV C159,214,148 CE0502257Z 2.2UF 50WV C38,103,182 CE0504757Z 4.
- 39 - RCI-6300F TB MISC. PARTS REFERENCE NUMBER RANGER PART NO. DESCRIPTION - PT9000060K FRONT PANEL - PT9000020E CH KNOB - PT9000070E BAND KNOB - PT9000040E INNER KNOB - PT9000050E OUTER KNOB - PT21.
RCI-6300F HP SCHEMATIC DIAGRAM.
RCI-6300F TURBO SCHEMATIC DIAGRAM.
RCI-6300F HP EXPLODE DRAWING.
RCI-6300F TURBO EXPLODE DRAWING.
AT6300040A COPYRIGHT 1999, RANGER COMMUNICATIONS INC..
Ein wichtiger Punkt beim Kauf des Geräts Ranger RCI-6300F TB (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Ranger RCI-6300F TB noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Ranger RCI-6300F TB - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Ranger RCI-6300F TB reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Ranger RCI-6300F TB erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Ranger RCI-6300F TB besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Ranger RCI-6300F TB verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Ranger RCI-6300F TB. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Ranger RCI-6300F TB gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.