Benutzeranleitung / Produktwartung 5100I-GD-B des Produzenten Quadra-Fire
Zur Seite of 44
DO NOT DISCARD THIS MANUAL NOTICE • I m p o r t a n t o p e r a t i n g and maintenance in- structions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E and Welcome to the Quadra-Fire Family ! .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Section 1: Listing and Code Approvals ...................... 4 .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E 1 Listing and Code Approvals .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E C. Negative Pressure Draft is the pressure difference needed to vent appliances .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 D. Flue Draft Considerations Location of the appliance and chimney will affect perfor- mance.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E 3 Dimensions and Clearances A. Appliance Dimensions T OP VIEW SIDE VIEW FRONT VIEW A B 39-1/8" (994mm) 26-3/4" (679mm) 9-.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Hearth Extension A B C F E Insert SideW all Fascia or T rim Mantel D Maximum Mantel Depth: 12 inches (305mm) B.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E F. Hearth Extension .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 NOTE: If your home is fairly airtight, it is recommend that you install the outside air that comes standard with the appli- .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E at the factory with the power cord on right side of insert (as you face the unit).
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Figure 13.1 C. Wiring Diagram & AN#ONTROL3PEED #ONTROL2HEOSTAT 3NAP$ISC 3NAP$ISC "Y0ASS 3WITCH ,INE 'ROUND .EUTRAL & AN & AN & & D.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E D. Masonry Chimney .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 UL 1777 Insulated Stainless Steel Liner or Other Approved Lining System Follow Manufacturer ’s Instructions on Insulation and .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E F . Prefabricated Metal Chimney Figure 16.1 E. Metal Heat Circulating Masonry .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Minimum Width of Cavity Opening 36 914 24 607 .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E Ovalizing round stainless steel liners to accommodate the allowable and acceptable practice.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 L. Chimney T ermination Requirements .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E Arestor Cap Double Wall Figure 20.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Figure 21.1 Figure 21.2 Figure 21.3 T wo leveling bolts, 3/8” x 4” are shipped inside the com- ponent pack found inside the rebox.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E Figure 22.1 Figure 22.2 .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Figure 23.1 Figure 23.2 Figure 23.3 Figure 23.4 E. Zero Clearance Adjustable T rim Support Size: 12” d x 50” w , 2-10” h .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E B. Wood Selection & Storage of the rain and snow .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 2. Second Stage .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E Odors and vapors released during initial operation. • Curing of high temperature paint.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 snap disc which will automatically turn the blower on when the insert reaches this temperature.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E CORRECT POSITION INCORRECT POSITIONS - ment is not covered by warranty .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 Odors and vapors are released during initial operation. • Curing of high temperature paint. • Open windows for air circulation. Odors may be irritating to sensitive individuals.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E 9 Maintaining & Servicing Y our Appliance A. General Maintenance Inspection: Inspect the system at the appliance connection and at the chi mne y top .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 4. Glass Cleaning • Frequency: As necessary • By: • T ask: Clean glass with a nonabrasive glass cleaner .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E B. Quick Reference Maintenance Guide 2 2 .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E E. Door Handle Assembly Replacement 1 . Install washer on door handle shaft. 3.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E H. Bafe Removal • Frequency: As needed • By: .
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 10 T roubleshooting With proper installation, operation, and maintenance your appliance provide years of trouble-free service.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E 1 1 Reference Materials A. Exploded Drawings Figure 38.1 7025-026 5-14-09.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 B. Service Parts & Accessories When requesting service or replacement parts for your appliance please provide model number and serial number . all parts listed may be orderd from an authorized dealer .
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E T o order the entire assembly , order the top line part number only . T o order an individual part from an assembly , order the part(s) listed in the indented portion.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010 T o order the entire assembly , order the top line part number only . T o order an individual part from an assembly , order the part(s) listed in the indented portion.
5100-I ACT WOOD INSERT April 21, 2010 R 438-0380E C. W arranty Policy.
5100-I ACT WOOD INSERT R 438-0380E April 21, 2010.
April 21, 2010 438-0380E R Hearth & Home T echnologies 1445 North Highway Colville, W A 991 14 Division of HNI INDUSTRIES CONT ACT INFORMA TION : Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer , please visit our web site at www .
Ein wichtiger Punkt beim Kauf des Geräts Quadra-Fire 5100I-GD-B (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Quadra-Fire 5100I-GD-B noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Quadra-Fire 5100I-GD-B - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Quadra-Fire 5100I-GD-B reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Quadra-Fire 5100I-GD-B erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Quadra-Fire 5100I-GD-B besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Quadra-Fire 5100I-GD-B verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Quadra-Fire 5100I-GD-B. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Quadra-Fire 5100I-GD-B gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.