R DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. HOT SURF ACES! Glass and other surfaces are hot during operation AND cool down. W ARNING Hot glass will cause burns.
3100-I ACT WOOD INSERT Page 2 September 1, 2008 R 250-6381D and Welcome to the Quadra-Fire Family ! H earth & Home T echnologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durability , and performance.
Page 3 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D SAFETY & OVER VIEW OF APPLIANCE Serial Number /Listing Label Location ------------------ 2 Dimensions -----------------------------------.
3100-I ACT WOOD INSERT Page 4 September 1, 2008 R 250-6381D INSERT DIMENSIONS T OP VIEW SIDE VIEW FRONT VIEW A B C L 27-7/16" (697mm) 14-1/8" (359mm) 38-7/8" (987mm) 12-3/16" (310m.
Page 5 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Hearth Extension A B C D F E Insert SideW all Maximum Mantel Depth - 10" (254mm) Fascia or T rim Mantel Thermal Protection USA & Can.
3100-I ACT WOOD INSERT Page 6 September 1, 2008 R 250-6381D A VOID FIRE: T o ensure that insulation or any other combustible material does not contact the chimney , a chimney inside the house must have at least 2 inches (51mm) of air space clearance around t he chimney .
Page 7 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D IF INST ALLING THIS MODEL TO A MASONR Y CHIMNEY , AL W A YS BE SURE THE CHIMNEY IS IN GOOD CONDITION AND THA T IT MEETS THE MINIMUM ST ANDARDS OF THE NA TIONAL FIRE PROTECTION ASSOCIA TION (NFP A) ST ANDARD 21 1.
3100-I ACT WOOD INSERT Page 8 September 1, 2008 R 250-6381D Floor Ceiling Caulk Floor (second Story) Non-Combustible Firestopping Material Minimum 1 inch (25mm) clearance from exterior chimney to shea.
Page 9 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D MASONR Y FIREPLACE USING DIRECT -CONNECT METHOD Refer to: Clearances to Combustibles on page 5, Canadian Installation requirements on page 1 1, Hearth Requirements on page 5 and Zero Clearance Adjustable Support Kit on page 14.
3100-I ACT WOOD INSERT Page 10 September 1, 2008 R 250-6381D The following modications of factory built replaces are permissible: 1) removal of damper; 2) removal of smoke shelf or bafe; 3) removal of ember catches; 4) removal of re grate; 5) removal of viewing screen/curtain; and, 6) removal of doors.
Page 1 1 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D INST ALLA TION IN CANADA MASONR Y and HEA T -CIRCULA TING (INST ALLA TIONS INTO F ACTORY -BUIL T FIREPLACES ARE PROHIBITED IN CANADA) Wheth.
3100-I ACT WOOD INSERT Page 12 September 1, 2008 R 250-6381D Vi ew of "L" Bracket installed Kit Includes: ( 2) Side Panels, left & right; (1) Panel T op & Fastener package; (2) Side T rim, left & right; (1) T rim T op & Fastener package.
Page 13 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Included in Kit: (2) Fan mounts & fan assemblies; (1) Speed Control, Power Cord/wire assembly; (1 set) Fan Connector wires, must be high temperature wire; and (1) Strain relief. T ools Needed: Large Phillips screwdriver , pliers F AN (BLOWER) INST ALLA TION INSTRUCTIONS Part No.
3100-I ACT WOOD INSERT Page 14 September 1, 2008 R 250-6381D ZERO CLEARANCE ADJUST ABLE TRIM SUPPORT , 2” to 10” Part No. 841-0990, size 9” x 45” and Part No.
Page 15 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D WOOD SELECTION AND STORAGE Burn only dry seasoned wood. Dry , well-seasoned wood will not only minimize the chance of creosote formation but will give you the most efcient heat output.
3100-I ACT WOOD INSERT Page 16 September 1, 2008 R 250-6381D BURN RA TES ST ARTING FIRE : Open both controls (push in) completely . After a wood load has been burning on high for 5 to 15 minutes or longer for very large pieces, close the Start-Up Air Control (right side) by pulling it out.
Page 17 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D AIR qUALITY AND YOUR qUADRA-FIRE INSERT In recent years there has been an increasing concern about the quality of our air . Much of the blame for poor air quality has been placed on the burning of wood for home heating.
3100-I ACT WOOD INSERT Page 18 September 1, 2008 R 250-6381D MAINTENANCE CARE AND CLEANING OF PLA TED SURF ACES IMPORT ANT : Y ou must clean all the ngerprints and oils from the plated surfaces before ring the insert for the rst time.
Page 19 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D BAFFLE REMOV AL & INST ALLA TION NOTE : The bafe in the 3100-I ACT Insert is 2700° Fiber Board.
3100-I ACT WOOD INSERT Page 20 September 1, 2008 R 250-6381D EXPLODED VIEW 1 9 10 11 2 4 3 8 6 7 5 Item Description Item Description 1 T rim Ring, Louver 7 Screen, Left/Right (interchange - able) 2 Ma.
Page 21 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Item # Part Description Alphabetical Order SKU 9 Bafe, Fiberboard 831-1800 10 Blanket, Ceramic, 1 inch thick 832-3401 Blower Assembly , w.
3100-I ACT WOOD INSERT Page 22 September 1, 2008 R 250-6381D 1 T rim Ring for Louver, Gold 430-2691 1 T rim Ring for Louver, Nickel 430-5430 Upgrade Kit to Nickel, Door UK-DRNL 14 W asher, Spacing SAE 3/8 for Door Handle 220-0010 Item # Part Description Alphabetical Order SKU ACCESSORIES 15 16 17 18 19 20 21 22 12 13 14 Item Description Part No.
Page 23 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Date of Service Performed By Description of Service Service And Maintenance Log.
3100-I ACT WOOD INSERT Page 24 September 1, 2008 R 250-6381D Date of Service Performed By Description of Service Service And Maintenance Log (Cont’d).
Page 25 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Homeowner ’ s Notes.
3100-I ACT WOOD INSERT Page 26 September 1, 2008 R 250-6381D W arranty Policy Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands ex.
Page 27 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or main- tenance of the.
Page 28 September 1, 2008 250-6381D R • Do NOT discard this manual. • Important operating and maintenance instructions included. • Read, understand and follow these instruci- tons for safe installation and operation. • Leave this manual with party responsible for use and operation.
Ein wichtiger Punkt beim Kauf des Geräts Quadra-Fire 3100-I (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Quadra-Fire 3100-I noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Quadra-Fire 3100-I - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Quadra-Fire 3100-I reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Quadra-Fire 3100-I erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Quadra-Fire 3100-I besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Quadra-Fire 3100-I verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Quadra-Fire 3100-I. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Quadra-Fire 3100-I gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.