Benutzeranleitung / Produktwartung ML100HPA des Produzenten Procom
Zur Seite of 23
INFRARED VENT -FREE PROP ANE/LP GAS SP ACE H E AT E R ML060HP A ML100HP A ML100TP A TOLL-FREE NUMBER: 1-877-886-5989 W ARNING: Improper installation, adjustment, alteration, service or mainte- nance can cause injury or property damage. Refer to this manual for correct installation and operational procedures.
2 IMPORT ANT SAFETY INFORMA TION Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible f or use with other gases.
3 PRODUCT IDENTIFICA TION SAFETY DEVICE A standard requirement for all vent-free room heaters. T his heater has a pilot with an Oxygen Depletion Sensor(ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater is equipped with a piezo ignitor.
4 FRESH AIR FOR COMBUSTION AND VENTILA TION PROVIDING ADEQUA TE VENTILA TION The following are excerpts from National Fuel Gas Code. NFP A 54/ANS Z223.1, Section 5.3. Air for Combustion and V entilation. All spaces in homes fall into one of the three following ventilation classifications: 1.
5 W ARNING: Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces. AIR FOR COMBUSTION AND VENTILA TION Continued VENTILA TION AIR V entilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
6 VENTILA TION AIR V entilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts: Y ou must provide two permanent openings: one within 12 " of the ceiling and one within 12 " of the floor. Connect these items directly to the outdoors or spaces open to the outdoors.
7 INST ALLA TION Figure 4 -Mounting clearances As V iewed From Front of Heater W ARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from floor, ceiling, and joining wall.
8 INST ALLA TION Figure 10 - Mounting Heater Onto Mounting Bracket Figure 8 - Folding Anchor Figure 9 - Popping Open Anchor Wing For Thin Walls Attaching Mounting Bracket T o W all Note: W all anchors, mounting screws, and spacers are in hardware package.
9 INST ALLA TION CONNECTING TO GAS SUPPL Y W ARNING: A qualified service person must connect heater to gas supply. Follow all local codes. W ARNING: This appliance requires a 3/8 " NPT (National Pipe Thread) inlet connection to the pressure regulator.
10 Figure 14 -Equipment Shutoff Valve INST ALLA TION CHECKING GAS CONNECTIONS W ARNING: T est all gas piping and connections for leaks after installing or servicing. Cor- rect all leaks at once. W ARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.
11 Figure 17 - Control Knob In The OFF Position Figure 18 - Pilot OPERA TING YOUR HEA TER Manual Control Models: ML060HP A,ML100HP A LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on the side of heater. 2. Check that gas supply to heater is on.
12 OPERA TING YOUR HEA TER THERMOST A T MODEL ML100TP A FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas.
13 INSPECTING BURNER Figure 24 - Correct Pilot Flame Pattern Figure 25 - Incorrect Pilot Flame Pattern Figure 27 - Incorrect Burner Flame Pattern Figure 26 - Correct Burner Flame Pattern ODS/PILOT AND BURNER Use a vacuum cleaner, pres - surized air, or a small, sof t bristled brush to clean.
14 TROUBLESHOOTING Note : All troubleshooting items are listed in order of operation. W ARNING: Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
15 TROUBLESHOOTING Continued OBSERVED PROBLEM Burner(s)does not light after ODS/pilot is lit. Delayed ignition of burner(s). Burner backfiring during combustion. Burner plaque(s) does not glow. Slight smoke or odor during initial operation. Heater produces a clicking/ticking noise just after burner is lit or shut off.
16 TROUBLESHOOTING Continued W ARNING: If you smell gas Shut off gas supply . Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone.
17 SPECIFICA TIONS Btu(available) Gas T ype Ignition Pressure Regulator setting Inlet Gas Pressure* (inches of water) Maximum Minimum Dimensions, Inches (HxWxD) Heater Carton Weight (pounds) Heater Shipping ML060HP A 6,000 propane/LP Only Piezo 10 " W.
18 ILLUSTRA TED P ARTS BREAKDOWN ML060HP A.
19 P ARTS LIST ML060HP A This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this manual.
20 ILLUSTRA TED P ARTS BREAKDOWN ML100HP A.
21 P ARTS LIST ML100HP A This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this manual.
22 ILLUSTRA TED P ARTS BREAKDOWN ML100TP A.
23 P ART LIST ML100TP A KEY NO. 1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PA R T NUMBER MB10007 MB09003 ML006-01 MB19006 ND1308x600x9 ND0803-6 ND0807-B2 ML026-02 ML069-02 845-4.
Ein wichtiger Punkt beim Kauf des Geräts Procom ML100HPA (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Procom ML100HPA noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Procom ML100HPA - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Procom ML100HPA reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Procom ML100HPA erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Procom ML100HPA besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Procom ML100HPA verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Procom ML100HPA. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Procom ML100HPA gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.