Pancake Compr essor Instruction manual The Model and Serial No. plate is located on the main housing of the tool. Record these numbers in the spaces below and retain for future reference. Model No. ______________________________________ Type ___________________________________________ Serial No.
2 - ENG D26126 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
3 - ENG D26126 IMPORT ANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.
4 - ENG D26126 HAZARD RISK OF BURSTING AIR TANK: THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY. HOW TO PREVENT IT WHAT CAN HAPPEN DRAIN TANK DAILY OR AFTER EACH USE.
5 - ENG D26126 HAZARD HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN RISK TO BREATHING AIR OBTAINED DIRECTLY FROM THE COMPRESSOR SHOULD NEVER BE USED TO SUPPLY AIR FOR HUMAN CONSUMPTION. IN ORDER TO USE AIR PRODUCED BY THIS COMPRESSOR FOR BREATHING, SUITABLE FILTERS AND IN-LINE SAFETY EQUIPMENT MUST BE PROPERLY INSTALLED .
6 - ENG D26126 HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN RISK OF BURNS TOUCHING EXPOSED METAL SUCH AS THE COMPRESSOR HEAD OR OUTLET TUBES, CAN RESULT IN SERIOUS BURNS. NEVER TOUCH ANY EXPOSED METAL PARTS ON COMPRESSOR DURING OR IMMEDIATELY AFTER OPERATION.
7 - ENG D26126 HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN RISK OF UNSAFE OPERATION REVIEW AND UNDERSTAND ALL INSTRUCTIONS AND WARNINGS IN THIS MANUAL. BECOME FAMILIAR WITH THE OPERATION AND CONTROLS OF THE AIR COMPRESSOR. KEEP OPERATING AREA CLEAR OF ALL PERSONS, PETS, AND OBSTACLES.
8 - ENG D26126 GLOSSAR Y SCFM or CFM: Standard Cubic Feet per Minute; a unit of measurement of air delivery. PSIG or PSI: Pounds per square inch gauge. CUT-IN PRESSURE : While the motor is off, air tank pressure drops as you continue to use your accessory or air tool.
9 - ENG D26126 HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air.
10 - ENG D26126 Extension Cords Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating. Attach extra air hoses at the air outlet instead of using extension cords.
11 - ENG D26126 DESCRIPTION OF OPERA TION Description of Operation Become familiar with these controls before operating the unit. On/Auto/Off Switch : Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use.
Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet. Check Valve: When the air compressor is operating, the check valve is "open”, allowing compressed air to enter the air tank.
13 - ENG D26126 Before Each Start-Up: 1. Place On/Auto/Off lever to "OFF" and close air regulator. 2. Pull regulator knob out, turn counterclockwise until it stops.
14 - ENG D26126 Customer Responsibilities Daily or after each use Before each use ● ● Check Safety Valve Drain Tank NOTE: See "Operation" section for the location of controls. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts.
15 - ENG D26126 Unit cycles automatically when power is on. When doing Maintenance, you may be exposed to voltage sources, compressed air or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure.
To Replace Regulator 1. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section. 2. Unplug unit. 3. Using an adjustable wrench remove the outlet pressure gauge and quick connect from the regulator. 4. Remove the regulator.
17 - ENG D26126 Before you store the air compressor, make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. 2. Set the On/Auto/Off lever to “OFF”. 3. Turn the regulator counterclockwise and set the outlet pressure to zero.
LIMITED WARRANTY Porter-Cable Corporation Jackson, TN USA 1-888-559-8550 PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship.
Ein wichtiger Punkt beim Kauf des Geräts Porter-Cable D26126-024-0 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Porter-Cable D26126-024-0 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Porter-Cable D26126-024-0 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Porter-Cable D26126-024-0 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Porter-Cable D26126-024-0 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Porter-Cable D26126-024-0 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Porter-Cable D26126-024-0 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Porter-Cable D26126-024-0. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Porter-Cable D26126-024-0 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.