Benutzeranleitung / Produktwartung CPF6020 des Produzenten Porter-Cable
Zur Seite of 18
Part No. D20814-004 Oilfr ee Compr essors Instruction manual T o learn more about Porter -Cable visit our website at: http://www .porter -cable.com The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for future reference.
2-ENG CAUTION indicates a potentially hazar dous situation which, if not avoided, may result in minor or moderate injury . This manual contains information that is important for you to know and understand. This infor - mation relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS .
3-ENG RISK OF BURSTING IT IS NORMAL FOR ELECTRICAL CONT ACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SP ARK. IF ELECTRICAL SP ARKS FROM COMPRESSOR COME INTO CONT ACT WITH FLAMMABLE V APORS, THEY MAY IGNITE, CAUSING FIRE OR EXPLOSION. RESTRICTING ANY OF THE COMPRESSOR VENTILA TION OPENINGS WILL CAUSE SERIOUS OVERHEA TING AND COULD CAUSE FIRE.
4-ENG RISK FROM FL YING OBJECTS IMPORT ANT SAFETY INSTRUCTIONS (cont’d) THE COMPRESSED AIR STREAM CAN CAUSE SOFT TISSUE DAMAGE TO EXPOSED SKIN AND CAN PROPEL DIRT , CHIPS, LOOSE P ARTICLES AND SMALL OBJECTS A T HIGH SPEED , RESUL TING IN PROPERTY DAMAGE OR PERSONAL INJUR Y .
5-ENG RISK FROM MOVING P ARTS RISK OF BURNS RISK OF F ALLING IMPORT ANT SAFETY INSTRUCTIONS (cont’d) WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT MOVING P ARTS SUCH AS THE PULLEY , FL YWHEEL, AND BEL T CAN CAUSE SERIOUS INJUR Y IF THEY COME INTO CONT ACT WITH YOU OR YOUR CLOTHING.
6-ENG CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measur e of air delivery . PSIG: Pounds per square inch gauge; a unit of measur e of pressure. ASME: American Society of Mechanical Engineers; made, tested, inspected, and register ed to meet the standards of ASME.
7-ENG DESCRIPTION OF OPERA TION Drain V alve (not shown): The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use. Motor Thermal Overload Protector (not shown): The electric motor has an automatic thermal overload protector .
8-ENG INST ALLA TION Installing Handles, Wheel, and Rubber Foot (Fig. 2) THE WHEELS AND HANDLE DO NOT PROVIDE ADEQUA TE CLEARANCE, ST ABILITY OR SUPPORT FOR PULLING THE UNIT UP AND DOWN ST AIRS OR STEPS. THE UNIT MUST BE LIFTED, OR PUSHED UP A RAMP . 1.
9-ENG Location of the Air Compr essor Locate the air compressor in a clean, dry , and well-ventilated area. The air filter must be kept clear of obstructions which could r educe air flow to the air compr essor . The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air .
10-ENG GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK! In the event of a short circuit, gr ounding reduces the risk of shock by providing an escape wire for the electric current.
11-ENG BREAK-IN PROCEDURES Serious damage may result if the following break-in instructions ar e not closely followed. This pr ocedure is r equir ed befor e the air compressor is put into service. (before the hose is installed), the check valve is r eplaced, or a complete compressor pump is replaced.
12-ENG SERVICE INSTRUCTIONS Air Filter - Inspection and R Air Filter - Inspection and R Air Filter - Inspection and R Air Filter - Inspection and R Air Filter - Inspection and R eplacement eplacement eplacement eplacement eplacement Keep the air filter clean at all times.
13-ENG 5. Unscr ew the check valve using a socket wrench. 6. Check that the valve disc moves freely inside the check valve and that the spring holds the disc in the upper , closed position. The check valve may be cleaned with a strong solvent. 7. Apply sealant to the check valve threads.
14-ENG CAUSE PERFORMING REP AIRS MA Y EXPOSE VOL T AGE SOURCES, MOVING P ARTS OR COMPRESSED AIR SOURCES. PERSONAL INJUR Y MA Y OCCUR. PRIOR TO A TTEMPTING ANY REP AIRS, UNPLUG THE AIR COMPRESSOR AND BLEED OFF ALL AIR T ANK AIR PRESSURE. PROBLEM CORRECTION TROUBLESHOOTING GUIDE Excessive tank pressure - safety valve pops off.
15-ENG CAUSE PROBLEM CORRECTION Motor will not run or restart. Motor overload pr otection switch has tripped. T ank pressure exceeds pr essure switch “cut-in” pr essure. W rong gauge wire or length of extension cor d. Check valve stuck open. Loose electrical connections.
16-ENG Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced. Possible defect in safety valve. Air leak from safety valve. CAUSE PROBLEM CORRECTION Knocking Noise. Malfunctioning check valve. Remove and clean, or replace.
17-ENG ACCESSORIES Accessories can be found at the stor e from which the unit was purchased or at a local hardware store. PLUMBING COMPONENTS CONNECTORS Connects components that have similar NPT threads; Male or Female. 360 O SWIVEL CONNECTOR Eliminates hose twist and improves tool handling.
18-ENG LIMITED WARRANTY POR TER-CABLE CORPORA TION warrants to the original purchaser that each new air compressor and service part is free fr om defects in material and workmanship and agrees to repair or replace under this warranty any defective pr oduct or part as follows fr om the original date of purchase.
Ein wichtiger Punkt beim Kauf des Geräts Porter-Cable CPF6020 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Porter-Cable CPF6020 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Porter-Cable CPF6020 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Porter-Cable CPF6020 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Porter-Cable CPF6020 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Porter-Cable CPF6020 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Porter-Cable CPF6020 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Porter-Cable CPF6020. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Porter-Cable CPF6020 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.