Benutzeranleitung / Produktwartung 472645 des Produzenten Pentair
Zur Seite of 28
Pentair Commercial Pool Heaters Ordering P/N 472645 MegaTherm™ MT — 500-5000 MBTU/h PowerMax™ PM — 500-2000 MBTU/h.
2 © 2006 Pentair W ater P ool and Spa, Inc. All rights reserved This document is subject to change without notice 1620 Hawkins A ve ., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles A ve .
3 MegaTherm MT Standard Features 500-5000 .................................. 4 Model Nomenclature .............................................. 4 Code Options .......................................................... 4 Features and Opti ons ........
4 S t andard Features MegaTherm MT (500-5000) MODEL MT -POOL REVISION P - PUMP 500-1825 A- 2000-5000 HEAT EXCHANGER C -GLASS LINED/COPPER N -GLASS LINES/CU-NI K -BRONZE/COPPER S -BRONZE/CU-NI VERSION 1-8 TUBE B-10 TUBE C-18 TUBE FUEL N -NATURAL P -PROPANE IGNITION 04- SPARK 110V 09- SPARK 24V (500-1825) 18- SPARK 24V (2000-5000) 16- STND.
5 500-1825 2000-2450 2800-5000 Ignition Systems System 4 N/A N/A O System 9 S N/A N/A System 16 O O O System 18 N/A S S Firing Mode On/Off S S S Motorized On/Off (FM & Minnesota Code only) N/A N/A.
6 • Automatic bypass • ASME 160 psi working pressure heat exchanger • ASME “H” stamp • Flanged water connections • Glass-lined cast iron headers • External header gaskets • 75 psi (8.
7 St andard Models - 4th Character Code Code 500 750 1000 1250 1500 1750 2000 Base model with std on/of f control, std copper P tube HX (requires heat exchanger option) with automatic by-pass, and nor.
P/N 472645 Rev A - 05/22/06 Litho in U .S.A.
Commercial Pool Heater Parts Sizes 210,000 - 5,000,000 BTU/h P/N 472645 Heater Name Model Sizes Doc. No. MegaTherm - Commercial Pool Heater MT 500-1825 472643 MegaTherm - Commercial Pool Heater MT 200.
2 Using “Genuine Pentair” parts will ensure accurate replacement and warranty coverage. Installation and Operation Manuals for current products are available on-line at http://www.pentairpool.com Our Commitment We believe the availability of factory authorized replacement parts is an essential component of customer service.
3 Part No. Description Model Size Part No. Description Model Size MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT Old style AP before April 1999, New style after April 1999 Sizes 500,000 - 1,825,000 BTU/h GAS SYSTEM BURNER TRAYS See listing in MegaTherm HH, PH, VW, PW and IW for common components.
4 Part No. Description Model Size Part No. Description Model Size MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes 500,000-1,825,000 10449521 Hi Tension Lead (orange/red wire from ignition ctrl to pilot lead) .
5 10667706 Baffle, HX (8 tube outdoor) (28 req) ......................................... both .. 1200 ........................ 10667707 Baffle, HX (8 tube outdoor) (28 req) ......................................... both .. 1430 ......................
6 Part No. Description Model Size Part No. Description Model Size MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes 500,000-1,825,000 MegaTherm AP, Sizes .
7 Part No. Description Size Part No. Description Size MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT MegaTherm Model MT Sizes 2,000,000 - 5,000,000 BTU/h MAIN GAS SYSTEM L2002200 Orifice Nat, #20 DMS ......................
8 MegaTherm MT, Sizes 2,000,000-5,000,000 MegaTherm MT, Sizes 2,000,000-5,000,000 MegaTherm MT, Sizes 2,000,000-5,000,000 MegaTherm MT, Sizes 2,000,000-5,000,000 MegaTherm MT, Sizes 2,000,000-5,000,000 Part No. Description Size Part No. Description Size 20011002 Lower Base Assy .
9 T2007000 Tile (9.25") ..................................... 3600,4050, ....................................................... 4000,4500I ........................ T2007002 Tile, Pyro, Front & Rear, Right see T2007000 models (AP) ...........
10 10417400 Flange, 4" cast iron (2 req) ............ all ...................................... 10416100 Return Header (double pass) ........ all ...................................... 20021100 Return Header, Bronze (double pass) ...............
11 20013801 Draft Hood Relief Baffle, Right .................................................. 20013802 Draft Hood Relief Baffle, Right .................................................. 20013803 Draft Hood Relief Baffle, Right .......................
12 20069400 Baffle Center Strap ........................ 3200/5000 ......................... 20015101 Flue End Assy, Left ....................... all ...................................... 20015102 Flue End Assy, Right ..................... all ......
13 NATURAL PRO PANE NAT URAL P ROPANE NATURAL P ROP ANE 0 - 2000 L0050700 L 2002200 L2011300 L2006400 L2002600 A #44 #20 #35 #24 #3 7 L 2001 - 3000 L0032900 L2006100 #54 #23 L2002500 L2006700 L20027 0.
14 T T T T T ile Assemblies - MT ile Assemblies - MT ile Assemblies - MT ile Assemblies - MT ile Assemblies - MT (AP After April 1999) Sizes 500,000 - 1,825,000 (Cement Tile) When ordering tiles: Assembly number is for all tiles. Part numbers shown at front of unit are the same for rear tiles.
15 T T T T T ile Assemblies - MT ile Assemblies - MT ile Assemblies - MT ile Assemblies - MT ile Assemblies - MT (AP Units Before April 1999) Sizes 500,000 - 1,825,000 (Pyro Tile) When ordering tiles: Assembly number is for all tiles. Part numbers shown at front of unit are the same for rear tiles.
16 T ile Assemblies - MT Sizes 2,000,000 - 5,000,000 (Pyro Tile) I=Indoor, E=Outdoor.
17 Part No. Description Size Part No. Description Size PowerMax PM PowerMax PM PowerMax PM PowerMax PM PowerMax PM Sizes 500,000 - 2,000,000 BTU/h COMBUSTION CHAMBER COMPONENTS 5C2600 Chamber Assy, Left, Bottom ......... 500-2000 .....................
18 ELECTRICAL COMPONENTS E2105500 Diagnostic Board ........................... 500-2000 ........................... R2027700 Relay, 10A, for Diagnostic Board (uses 3) .......................................... 500-2000 ........................... RE0013000 Flow Switch .
19 PowerMax PM PowerMax PM PowerMax PM PowerMax PM PowerMax PM Part No. Description Size 5C3002 Plate, Cover, Filter ......................... 500-1000 ........................... 15C3002 Plate, Cover, Filter ......................... 1250-2000 ......
© 2006 Pentair W ater P ool and Spa, Inc. All rights reserved This document is subject to change without notice 1620 Hawkins A ve ., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles A ve .
Ein wichtiger Punkt beim Kauf des Geräts Pentair 472645 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Pentair 472645 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Pentair 472645 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Pentair 472645 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Pentair 472645 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Pentair 472645 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Pentair 472645 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Pentair 472645. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Pentair 472645 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.