USER MANUAL MODEL 2707C, D G.703 NTU with V .35, X.21 Interfaces SALES OFFICE (301) 975-1000 TECHNICAL SUPPOR T (301) 975-1007 P ar t# 07M2707-UM Doc# 08619U2-001, Rev .
1 T ABLE OF CONTENTS 1.0 Warranty Information ................................................................. 2 1.1 FCC Information ........................................................................... 2 1.2 CE Notice..........................
2 1.0 W ARRANTY INFORMATION P atton Electronics warrants all Model 2707 components to be free from def ects, and will—at our option—repair or replace the product should it f ail within one year from the first date of shipment.
3 1.3 SERVICE All warranty and nonw arranty repairs must be returned freight prepaid and insured to P atton Electronics. All returns must hav e a Return Mate- rials Authorization number on the outside of the shipping container .
4 2.0 GENERAL INFORMATION Thank you f or your purchase of this P atton Electronics product. This product has been thoroughly inspected and tested and is warranted f or One Y ear parts and labor .
5 3.0 CONFIGURATION The Model 2707 f eatures configuration capability via hardware DIP s witches. This section descr ibes all possible DIP s witch configurations of the Model 2707. 3.1 DIP SWITCH CONFIGURATION The Model 2707 has one internal DIP switch that allow configur ation f or a wide range of applications.
6 Figure 2. Close up of configuration s witches Switch SW1-1 thr ough SW1-8 Switch SW1-1 Line Coding: HDB3 (default) Use Switch SW1-1 to control the Network Line Coding options. Set these options to be the same as the Line Coding given to y ou by your Ser vice Provider .
7 Options: HDB3, AMI HDB3: In this line coding, the transmitter substitutes a deliberate bipolar violation when e xcessive z eros in the data stream are detected. The receiver recogniz es these special violations and decodes them as z eros . This method enables the netw ork to meet minimum pulse density requirements.
8 SW1-6 and SW1-7 Clock Modes Use Switches SW1-6 and SW1-7 to configure the 2707 f or internal, e xternal, or receive recov er clock mode. SW1-8: Enable/Disable Loop T ests from DTE Use Switch SW1-8 to allow Model 2707 to enter loopbac k tests when the DTE raises the appropriate loop request pin.
9 4.0 INSTALLATION Once the Model 2707 is properly configured, it is ready to connect to the G.703 interf ace , to the serial por t, and to the power source . This section describes how to make these connections . 4.1 CONNECTING T O THE G.703 NETWORK The P ower , G.
10 Connecting the T wisted Pair (120 Ohm) to the G.703 Netw ork The Model 2707 is equipped with a single RJ-48C jack f or connections to a 120 Ohm twisted pair G.703 network interface . If your G.703 network terminates via RJ-48C, use Figure 4 below to connect the 120 Ohm G.
11 The DCE/DTE strap is located near the DB15 connector on the top side of the board. The arro ws on the top of the strap indicate the configura- tion of the X.21 por t (for e xample, if the DCE arrows are pointing to ward the DB-15 connector , the X.
12 DC P ower The 36-60 VDC DC to DC adapter is supplied with the DC version of the Model 2707. The b lack and red leads plug into a DC source (nominal 48VDC) and the barrel power connector plugs into the barrel po wer sup- ply jack on the 2707. (See Figure 5).
13 5.0 OPERATION When the Model 2707 has been properly configured and installed, it should operate transparently . This sections describes pow er-up, LED status monitors, and the b uilt-in loopback test modes. 5.1 POWER-UP Bef ore applying power to the Model 2707, please read section 4.
14 5.3 LOCAL LOOP DIAGNOSTICS The Model 2707 off ers V .54 loop diagnostics. Use these diagnostics to test the NTU and any communication links . This test can be activated via DIP s witches or via signals on the Model 2707 serial por t interface.
15 APPENDIX A MODEL 2707, G.703 SPECIFICATIONS Network Data Rate: 2.048 Mbps Network Connector : RJ-48C/Dual Coax BNC (2707/D) Nominal Impedance: 75/120 Ohm Line Coding: Selectable AMI or HDB3 Line F raming: G.703 (Unframed) Clocking: Internal or Network (Receive Recov er) Distance: Maximum 1.
16 APPENDIX B MODEL 2707, INTERFACE PIN ASSIGNMENT V .35 Interf ace (M/34F F emale Connector) (DCE Configuration) Pin # Signal B SGND (Signal Ground) C R TS (Request to Send) D CTS (Clear to Send) E .
17 APPENDIX B - Continued V .35 T O V .35 (STRAIGHT - THROUGH CABLE) PIN OUT V .35 T O V .35 (CROSS O VER CABLE) PIN OUT PIN Function PIN Function PIN A F rame Ground A F rame Ground A B Signal Ground.
18 APPENDIX C MODEL 2707, INTERFACE PIN ASSIGNMENT X.21 Interf ace (DB-15 F emale Connector) (DTE/DCE Configuration) Pin # Signal 1 F rame Ground 2 T (T ransmit Data-A) 3 C (Control-A) 4 R (Receive D.
19 APPENDIX D MODEL 2707, FACTORY REPLACEMENT PARTS AND ACCESSORIES Cop yright © 2006 P atton Electronics Company All Rights Reser ved. Model # Description 2707/C G.
Ein wichtiger Punkt beim Kauf des Geräts Patton electronic 2707C, 2707D (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Patton electronic 2707C, 2707D noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Patton electronic 2707C, 2707D - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Patton electronic 2707C, 2707D reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Patton electronic 2707C, 2707D erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Patton electronic 2707C, 2707D besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Patton electronic 2707C, 2707D verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Patton electronic 2707C, 2707D. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Patton electronic 2707C, 2707D gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.