USER MANU AL MODEL 1186 Multi-Mode Fiber Modem with Fixed G.703/G.704 Interface Part# 07M1 186-UM Doc# 01716U2-001, Rev . C Revised 10/25/06 SALES OFFICE (301)975-1000 TECHNICAL SUPPORT (301)975-1007 http://www .
T T A A B B L L E E O O F F C C O O N N T T E E N N T T S S Section Page 1.0 W arranty Information .............................................................2 1.1 Radio and TV Interference 1.2. CE Notice 1.3 Service.................................
1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container . This number may be obtained from Patton Electronics T echnical Service at: tel: (301)975-1007 email: support@patton.
3 3 . . 0 0 C C O O N N F F I I G G U U R R A A T T I I O O N N The Model 1 186 is equipped with eight DIP switches, which allow configuration of the unit for a wide variety of applications. This section describes the switch location and explains all possible configurations.
7 data stream are detected. The receiver recognizes these special violations and decodes them as zeros. This method enables the network to meet minimum pulse density requirements. Use HDB3 unless AMI is required in your application. Alternate Mark Inversion (AMI) : AMI defines a pulse as a “mark,” a binary one, as opposed to a zero.
9 4 4 . . 0 0 I I N N S S T T A A L L L L A A T T I I O O N N Once the Model 1 186 is properly configured, it is ready to connect to the fiber interface, to the G.703/G.704 equipment, and to the power source. This section describes how to make these connections.
11 4.3 POWER CONNECTION 4.3.1 Universal AC Power (100-240V AC) The Model 1 186 uses a 5VDC, 2A universal input 100-240V AC, power supply (center pin is +5V). The universal input power supply has a male IEC-320 power entry connector . This power supply con- nects to the Model 1 186 by means of a barrel jack on the rear panel.
Functions of LEDs are as follows: Fiber The green Fiber LED indicates reliable data on the fiber side E1 The green E1 LED indicates reliable data on the G.703/G.704 side LOS The red LOS indicates that syncronization between modems has not been established.
5.3.2. Remote Digital Loopback (RDL) The Remote Digital Loopback test checks the performance of both the local and remote Model 1 186s, and the communication link between them. In this test, any characters sent from the originating device to the remote unit will be returned (see Figure 12).
A A P P P P E E N N D D I I X X A A P A TTON ELECTRONICS MUL TI-MODE FIBER MODEM WITH G.703/G.704 FIBER INTERF ACE SPECIFICA TIONS Clocking Modes: Network (G.703/G.704), Internal, Receive Recover Line Rate: 2048 kbps Diagnostics: V .52 compliant (51 1/51 1E) pattern generator and detector with error injection mode.
A A P P P P E E N N D D I I X X B B P A TTON ELECTR ONICS MODEL 1186 F ACT ORY REPLA CEMENT P ARTS AND ACCESSORIES Patton Electronics Model # Description 1 186 ................................multi-mode fiber optic modem 1 186RC.......................
Ein wichtiger Punkt beim Kauf des Geräts Patton electronic 1186 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Patton electronic 1186 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Patton electronic 1186 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Patton electronic 1186 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Patton electronic 1186 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Patton electronic 1186 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Patton electronic 1186 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Patton electronic 1186. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Patton electronic 1186 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.