USER MAN U A L MODEL 1094A NetLink™ HDSL Multi-Rate Symmetric DSL Modem Part# 07M1094A-B Doc# 032042UB Revised 07/22/99 SALES OFFICE (301)975-1000 TECHNICAL SUPPO R T (301)975-1007 http://ww w .
T T A A B B L L E E O O F F C C O O N N T T E E N N T T S S SECTION P AGE 1.0 W arranty Information .............................................................2 1.1 Radio and TV Interference 1.2. CE Notice 1.3 Service 2.0 General Information .......
1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container . This number may be obtained from Patton Electronics T echnical Service at: T el: (301)975-1007 Email: support@patton.
3 3 . . 0 0 C C O O N N F F I I G G U U R R A A T T I I O O N N The Model 1094A is equipped with three sets of eight DIP switch- es, which allow configuration of the unit for a wide variety of applica- tions. This section describes switch locations and explains all possible configurations.
7 Switches S2-6 and S2-7: Clock Mode Use Switches S2-6 and S2-7 to configure the 1094A for internal, external, or receive recover clock mode. Switch S2-8: Enable/Disable Loop T ests from DTE Use Switch S2-8 to allow Model 1094A to enter loopback tests when the DTE raises the appropriate loop request pin.
9 Switch S3-7: Reset Software Defaults Switch S3-7 allows the user to reset the software configured facto- ry defaults. S3-7 Factory T est On Normal Operation Off Reset Switch S3-8: T ransmit Data (TD) Sampling Point Switch 3-8 controls the T ransmit Data (TD) sampling point.
11 4.2 CONNECTING THE SERIAL PORT The serial port interface on the Model 1094A uses interchange- able QuikConnect™ Modules. Each QuikConnect™ Module has a 50-pin card edge connector on one side and a serial port interface on the other . Figure 4 below shows how a QuikConnect™ Module plugs into the back of the Model 1094A.
4.2.4 Configuring the X.21 QuikConnect™ Module The serial port on the X.21 QuikConnect™ Module is default wired as a DCE, but may be switched to a DTE. This is done by reversing the orientation of the DCE/DTE strap, as described below: T o reverse DCE/DTE orientation, remove the module according to the instructions in Section 4.
5 5 . . 0 0 O O P P E E R R A A T T I I O O N N Once the Model 1094A is properly configured and installed, it should operate transparently . This sections describes power-up, read- ing the LED status monitors, and using the built-in loopback test modes.
Framer The framer is used to determine the status of the line. In normal operation the framer trans- mits and expects to receive framed packets from the far end. If the framer receives framed packets from the far end, CTS and CD will be active. If framed packets are not received, CTS and CD will be inactive.
5.3.2 Loops and Patterns The following section describes the T est Modes used in the Model 1094A. At the bottom of each T est Mode, a figure is included to show the data path. Local Loop There are two different modes of operation for a Local Loop depending on the status of the units at the time that the Local Loop is initiated.
Local Loop After the 51 1/51 1E pattern times out, the ER led with 51 1/51 1E will begin flashing. It will remain this way until (continued) the pattern generator switch is turned off. Note that the data at the local DTE and the remote DTE are not valid.
Remote Digital The Remote Digital Loop with 51 1/51 1E is Loop with shown above. After RDL is established the 51 1/51 1E Remote units' Restart T imer is set to one minute. This has been done because when the 51 1/51 1E generator is started on the local unit, the Remote framer begins seeing unframed packets.
5.3.3 Using the V .52 (BER) T est Pattern Generator T o use the V .52 BER tests in conjunction with the Remote Digital Loopback tests (or with Local Line Loopback tests), follow these instructions: 1. Locate the “51 1/51 1E” toggle switch on the front panel of the 1094A and move it UP .
A A P P P P E E N N D D I I X X B B P A TTON ELECTRONICS MODEL 1094A F ACTOR Y REPLACEMENT P ARTS AND ACCESSORIES Patton Electronics Model # Description IM1/A ...............................V .24 with DB25F IM1/B ...............................RS422/RS530 with DB25F IM1/C .
A A P P P P E E N N D D I I X X C C P A TTON ELECTRONICS MODEL 1094A INTERF ACE PIN ASSIGNMENTS (Continued) V .35 Interface (M/34F Female Connector) (DCE Configuration) Pin # Signal B ...........................SGND (Signal Ground) C .................
A A P P P P E E N N D D I I X X D D P A TTON ELECTRONICS MODEL 1094A TRANSMISSION DIST ANCES Copyright © 1999 Patton Electronics Company All Rights Reserved 31 Line Rat e DTE Rates kbps feet m iles km feet miles km 144 64, 128 20700 3.9 6.2 24500 4. 6 7.
Ein wichtiger Punkt beim Kauf des Geräts Patton electronic 1094A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Patton electronic 1094A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Patton electronic 1094A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Patton electronic 1094A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Patton electronic 1094A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Patton electronic 1094A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Patton electronic 1094A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Patton electronic 1094A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Patton electronic 1094A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.