USER MANUAL MODEL 1090 High Speed Synchronous Short Range Modem SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www .patton.com Part# 07M1090-B Doc# 03201 1UB Revised 5/26/98 CERTIFIED An ISO-9001 Certified Company Dear V alued Customer , Thank you for purchasing Patton Electronics products! W e do appreciate your business.
1.0 W ARRANTY INFORMA TION Patton Electronics warrants all Model 1090 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
2.0 GENERAL INFORMA TION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Y ear parts and labor .
SWITCH SET S1 The configuration switches on S1 set clock source, RTS/CTS delay , carrier control, loopback tests. The default settings are summarized in Figure 3 (above). S1-1 and S1-2: Clock Source Switches S1-1 and S1-2 are set in combination to determine the source of timing for the Model 1090.
S1-8: V .54 Enable / Disable The setting for switch S1-8 determines whether the Model 1090 will respond when it receives the V .54 sequence. If you suspect the Model 1090 may be getting tricked into the loopback test by false detection of user data, you can try setting this to “Disable.
When connecting two Model 1090’s, it is necessary to use a crossover cable. The diagram below shows how a crossover cable should be constructed. RJ-45 Cable (4-Wire) SIGNAL PIN# PIN# SIGNAL XMT+ 1 -.
4.2.2 CONNECTION TO A “DTE” DEVICE The serial port on most QuickConnect™ interface modules (all except the X.21 module) is hard-wired as a DCE. Therefore these modules “want” to plug into a DTE such as a terminal, PC or host.
5.0 OPERA TION Once the Model 1090 is properly configured and installed, it should operate transparently . This sections describes power-up, reading the LED status monitors, and using the built-in loopback test modes. 5.1 POWER-UP Before applying power to the Model 1090, first be sure that you have read Section 4.
B. V erify that the data terminal equipment is operating properly and can be used for a test. If a fault is indicated, call a technician or replace the unit.
5.3.4 V .52 BER TEST GENERA TOR The Model 1090 has a built-in test pattern generator and detector . It can be invoked at both ends of a link simultaneously or it can be used with the Local Analog, Remote Digital or Local Digital Loopbacks.
APPENDIX B 1090 CABLE RECOMMENDA TIONS The Patton Model 1090 operates at frequencies of 160 kHz or less and has been performance tested by Patton technicians using twisted-pair cable with the following characteristics: Wire Gauge Capacitance Resistance 19 A WG 83nF/mi or 15.
APPENDIX D M/34F Connector-DCE (V .35 Interface) Pin # Signal B SGND (Signal Ground) C RTS (Request to Send) D CTS (Clear to Send) E DSR (Data Set Ready) F CD (Carrier Detect) H DTR (Data Transfer Rea.
APPENDIX D 1090 INTERF ACE PIN ASSIGNMENT T ABLES M/34F Connector-DCE (V .35 Interface) Pin # Signal B SGND (Signal Ground) C RTS (Request to Send) D CTS (Clear to Send) E DSR (Data Set Ready) F CD (C.
APPENDIX D DB-15F Connector-DCE Setting (X.21 Interface) Pin # Signal 1 . . . . . . . . . . . . Frame Ground 2 . . . . . . . . . . . . T ( T ransmit Data-A) 3 . . . . . . . . . . . . C (Control-A) 4 . . . . . . . . . . . . R (Receive Data-A) 5 . . . .
Ein wichtiger Punkt beim Kauf des Geräts Patton electronic 1090 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Patton electronic 1090 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Patton electronic 1090 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Patton electronic 1090 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Patton electronic 1090 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Patton electronic 1090 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Patton electronic 1090 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Patton electronic 1090. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Patton electronic 1090 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.